DSC

聚合物分析用差示扫描量热仪

DSCA · Polymer Analysis Equipment · 6 models

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 11357-1, ISO 11357-2, ISO 11357-3

Standards referenced

  • ISO 11357-1
  • ISO 11357-2
  • ISO 11357-3
  • ASTM D3418
  • ASTM E1356
  • ASTM D3895
  • IEC 61010-1

What are DSC?

Differential scanning calorimetry for polymer analysis measures the heat flow into and out of a polymer sample as its temperature changes, revealing glass transition, melting, crystallisation, cure and oxidative stability. It is used for polymer identification, grade comparison, process troubleshooting and incoming material verification.

6 models of DSC

The 6 models below are current configurations; specifications are confirmed on quotation.

Heat-Flux DSC for Polymer Analysis

聚合物分析用热流型差示扫描量热仪

  • DSCA-0001
  • DSC
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Temperature range:
−150 to 600 °C with cooling accessory
Heating rate:
0.1–80 °C/min
Cooling rate:
Up to 50 °C/min with liquid nitrogen
Calorimetric accuracy:
±1% (indium)
Temperature accuracy:
±0.2 °C (indium)
Sensor type:
Disc-type thermocouple array

A heat-flux DSC measures the temperature difference between a polymer sample and reference pan sitting on a thermoelectric disc, giving robust transition data for filled, heterogeneous or irregular samples. It is the usual choice for routine polymer QC and for materials that cannot be cut into thin, uniform pieces.

Request a quote
View details

Power-Compensation DSC for Polymer Analysis

聚合物分析用功率补偿型差示扫描量热仪

  • DSCA-0002
  • DSC
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Temperature range:
−90 to 550 °C with cooling system
Heating rate:
0.1–200 °C/min
Cooling rate:
Up to 100 °C/min with mechanical cooling
Calorimetric accuracy:
±0.5% (indium)
Temperature accuracy:
±0.1 °C (indium)
Calorimetric precision:
±0.1%

A power-compensation DSC heats the sample and reference holders independently and records the difference in electrical power required to keep them equal. Its fast response and high resolution make it suitable for weak transitions, thin films, blends and kinetic studies on small polymer samples.

Request a quote
View details

Modulated-Temperature DSC for Polymer Analysis

聚合物分析用调制温度差示扫描量热仪

  • DSCA-0003
  • DSC
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Temperature range:
−90 to 600 °C with cooling accessory
Underlying heating rate:
0.1–10 °C/min during modulation
Modulation amplitude:
0.1–3 °C
Modulation period:
20–200 s
Calorimetric accuracy:
±1% (indium)
Specific heat accuracy:
±2% at 25 °C

A modulated-temperature DSC superimposes a small sinusoidal oscillation on a linear heating ramp and separates the response into reversing and non-reversing components. It resolves weak glass transitions hidden under overlapping melting or curing peaks in complex polymer systems.

Request a quote
View details

Differential Scanning Calorimeter with Autosampler for Polymer QC

聚合物质控用自动进样差示扫描量热仪

  • DSCA-0004
  • DSC
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Autosampler capacity:
20–50 positions
Temperature range:
−90 to 600 °C with cooling
Heating rate:
0.1–100 °C/min
Calorimetric accuracy:
±1% (indium)
Temperature accuracy:
±0.2 °C (indium)
Typical cycle time per sample:
20–40 min for heat-cool-heat

A DSC with an autosampler loads, measures and removes polymer samples automatically from a tray, so a laboratory can run overnight series of routine QC measurements. It suits high-throughput sites where identity verification and grade checks are repeated across many batches.

Request a quote
View details

Simultaneous DSC-TGA Analyzer for Polymer Analysis

聚合物分析用同步 DSC-TGA 分析仪

  • DSCA-0005
  • DSC
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Temperature range:
Ambient to 1500 °C
Heating rate:
0.1–50 °C/min
Balance resolution:
0.1 µg
Weighing accuracy:
±0.5%
Typical sample mass:
5–20 mg
Calorimetric accuracy:
±2% (indium)

A simultaneous DSC-TGA analyzer measures heat flow and mass change on the same polymer sample in one experiment. It is the right instrument when melting, curing or decomposition events overlap, because mass loss identifies which thermal event involves volatilisation or degradation.

Request a quote
View details

High-Temperature DSC for Engineering Polymers

工程塑料用高温差示扫描量热仪

  • DSCA-0006
  • DSC
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety compliance (to be confirmed)
Temperature range:
Ambient to 1500 °C (optional 1600 °C)
Heating rate:
0.1–50 °C/min
Temperature accuracy:
±2 °C at 1000 °C
Calorimetric accuracy:
±3% for metal standards
Sensor type:
Platinum or platinum-rhodium thermocouples
Sample holder material:
Alumina, platinum or ceramic crucibles

A high-temperature DSC extends the cell to about 1600 °C so that engineering and high-performance polymers, composites and their inorganic fillers can be characterised in one instrument. It is specified when polyimide, polyether ether ketone or ceramic-filled systems exceed ordinary cell limits.

Request a quote
View details

Compare DSC models

ModelTemperature rangeHeating rateCooling rateCalorimetric accuracyTemperature accuracy
Heat-Flux DSC for Polymer AnalysisDSCA-0001−150 to 600 °C with cooling accessory0.1–80 °C/minUp to 50 °C/min with liquid nitrogen±1% (indium)±0.2 °C (indium)
Power-Compensation DSC for Polymer AnalysisDSCA-0002−90 to 550 °C with cooling system0.1–200 °C/minUp to 100 °C/min with mechanical cooling±0.5% (indium)±0.1 °C (indium)
Modulated-Temperature DSC for Polymer AnalysisDSCA-0003−90 to 600 °C with cooling accessory——±1% (indium)—
Differential Scanning Calorimeter with Autosampler for Polymer QCDSCA-0004−90 to 600 °C with cooling0.1–100 °C/min—±1% (indium)±0.2 °C (indium)
Simultaneous DSC-TGA Analyzer for Polymer AnalysisDSCA-0005Ambient to 1500 °C0.1–50 °C/min—±2% (indium)—
High-Temperature DSC for Engineering PolymersDSCA-0006Ambient to 1500 °C (optional 1600 °C)0.1–50 °C/min—±3% for metal standards±2 °C at 1000 °C

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do DSC work?

A DSC cell holds the sample and an empty reference pan on a common sensor plate inside a furnace programmed through a controlled temperature ramp. The instrument records the differential heat flow needed to keep sample and reference at the same temperature, in milliwatts, against the furnace temperature or time. Endothermic events such as melting and volatilisation appear as peaks, and exothermic events such as crystallisation and curing appear as positive deviations. Heat-flux cells measure the temperature difference across a thermoelectric disc, while power-compensation cells heat the two holders separately and record the power difference directly. Calibration uses the melting point and enthalpy of indium, and often zinc and tin, with a sapphire disc for specific-heat calibration. Purge gas, sample mass, pan type and heating rate all influence peak shape and the temperatures reported for polymers.

Which DSC variants are available?

  • Heat-Flux DSC for Polymer Analysis — A heat-flux DSC measures the temperature difference between a polymer sample and reference pan sitting on a thermoelectric disc, giving robust transition data for filled, heterogeneous or irregular samples.
  • Power-Compensation DSC for Polymer Analysis — A power-compensation DSC heats the sample and reference holders independently and records the difference in electrical power required to keep them equal.
  • Modulated-Temperature DSC for Polymer Analysis — A modulated-temperature DSC superimposes a small sinusoidal oscillation on a linear heating ramp and separates the response into reversing and non-reversing components.
  • Differential Scanning Calorimeter with Autosampler for Polymer QC — A DSC with an autosampler loads, measures and removes polymer samples automatically from a tray, so a laboratory can run overnight series of routine QC measurements.
  • Simultaneous DSC-TGA Analyzer for Polymer Analysis — A simultaneous DSC-TGA analyzer measures heat flow and mass change on the same polymer sample in one experiment.
  • High-Temperature DSC for Engineering Polymers — A high-temperature DSC extends the cell to about 1600 °C so that engineering and high-performance polymers, composites and their inorganic fillers can be characterised in one instrument.

How do I choose the right variant?

The first decision is cell type. Heat-flux cells cope with larger samples and give robust results in routine polymer QC; power-compensation cells offer faster response and better resolution of weak transitions, which helps in research on blends and thin films. Then fix the temperature range: below-ambient capability needs a liquid nitrogen or mechanical cooling accessory, while engineering polymers need a cell rated to at least 600 °C. Sensitivity matters when a weak glass transition in a highly filled compound must be detected, and an autosampler matters above roughly twenty samples per day. Where decomposition begins close to a melting or curing event, choose a simultaneous DSC-TGA instrument so mass loss and heat flow are recorded on the same sample.

Where are DSC used?

DSC are specified in glass transition and melting point determination of polymers, degree of crystallinity and crystallisation kinetics, cure monitoring of thermosetting resins, oxidative induction time for polyolefin stability, incoming verification of resin grade identity and blend and copolymer composition studies.

Which standards and certifications apply?

Work with DSC is commonly governed by ISO 11357-1, ISO 11357-2, ISO 11357-3, ASTM D3418, ASTM E1356, ASTM D3895 and IEC 61010-1. Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

Calibrate temperature and enthalpy with indium before each campaign, or at least monthly, and check the baseline with an empty pair of pans. Seal volatile or moisture-sensitive samples in hermetic pans and work with a dry inert purge gas to suppress oxidation and ice formation. Sample mass of 5 to 10 mg in a standard pan usually balances resolution and thermal lag; heavy fillers may need more mass and slower heating rates. Keep the cell clean, record cooling conditions together with heating data because thermal history controls crystallinity, and store the raw curves so that re-analysis with different limits remains possible.

Frequently asked questions about DSC

A DSC gives transition temperatures and the heat associated with each event: glass transition, melting and crystallisation temperatures, enthalpy of fusion and hence degree of crystallinity, cure exotherm, specific heat and oxidative induction time. Comparing these values with a reference grade supports identification, batch verification and troubleshooting of processing problems.

Need help specifying DSC?