Heat-Flux DSC for Polymer Analysis — product photo

Heat-Flux DSC for Polymer Analysis

聚合物分析用热流型差示扫描量热仪

  • SKU DSCA-0001
  • DSC
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Temperature range−150 to 600 °C with cooling accessory
Heating rate0.1–80 °C/min
Cooling rateUp to 50 °C/min with liquid nitrogen
Calorimetric accuracy±1% (indium)
Temperature accuracy±0.2 °C (indium)
Sensor typeDisc-type thermocouple array
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 11357-1, ISO 11357-2, ISO 11357-3

What is the Heat-Flux DSC for Polymer Analysis?

A heat-flux DSC measures the temperature difference between a polymer sample and reference pan sitting on a thermoelectric disc, giving robust transition data for filled, heterogeneous or irregular samples. It is the usual choice for routine polymer QC and for materials that cannot be cut into thin, uniform pieces.

What is the Heat-Flux DSC for Polymer Analysis?

A heat-flux DSC measures the temperature difference between a polymer sample and reference pan sitting on a thermoelectric disc, giving robust transition data for filled, heterogeneous or irregular samples. It is the usual choice for routine polymer QC and for materials that cannot be cut into thin, uniform pieces.

Overview

In a heat-flux cell the sample and reference pans rest on a constantan or chromel disc that forms a thermocouple array, so the measured signal is proportional to the heat-flow difference between the two positions. Because the pans sit in a fairly large, well-insulated furnace, temperature gradients across a sample are small and the cell tolerates samples with poor contact or high filler content. Sensitivity is lower than in power-compensation designs and response is slower, which broadens sharp melting peaks slightly, but the measurement is less sensitive to sample preparation. Most units accept both standard and large-volume crucibles, support sub-ambient operation with a liquid nitrogen accessory, and can switch between inert and oxidative purge gases for oxidative induction time tests.

How does it work?

A DSC cell holds the sample and an empty reference pan on a common sensor plate inside a furnace programmed through a controlled temperature ramp. The instrument records the differential heat flow needed to keep sample and reference at the same temperature, in milliwatts, against the furnace temperature or time. Endothermic events such as melting and volatilisation appear as peaks, and exothermic events such as crystallisation and curing appear as positive deviations. Heat-flux cells measure the temperature difference across a thermoelectric disc, while power-compensation cells heat the two holders separately and record the power difference directly. Calibration uses the melting point and enthalpy of indium, and often zinc and tin, with a sapphire disc for specific-heat calibration. Purge gas, sample mass, pan type and heating rate all influence peak shape and the temperatures reported for polymers.

What are the key features?

  • Thermoelectric disc sensor with stable baseline
  • Temperature range from about −150 °C with cooling accessory
  • Accepts standard and large-volume crucibles
  • Switchable inert and oxidative purge gases
  • Tolerates filled and irregular polymer samples
  • Calibration kit with indium and zinc standards

What are the technical specifications?

A typical heat-flux dsc for polymer analysis configuration offers temperature range of −150 to 600 °C with cooling accessory, heating rate of 0.1–80 °C/min, cooling rate of Up to 50 °C/min with liquid nitrogen, calorimetric accuracy of ±1% (indium), temperature accuracy of ±0.2 °C (indium) and sensor type of Disc-type thermocouple array. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Heat-Flux DSC for Polymer Analysis is used in batch verification of filled thermoplastics, melting and crystallisation temperature checks, oxidative induction time of polyolefin compounds and cure studies on composite moulding compounds. Across the wider DSC class, laboratories also deploy it for glass transition and melting point determination of polymers, degree of crystallinity and crystallisation kinetics and cure monitoring of thermosetting resins.

Which standards and certifications apply?

Relevant standards and methods include ISO 11357-1, ISO 11357-2, ISO 11357-3, ASTM D3418, ASTM E1356, ASTM D3895 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Calibrate temperature and enthalpy with indium before each campaign, or at least monthly, and check the baseline with an empty pair of pans. Seal volatile or moisture-sensitive samples in hermetic pans and work with a dry inert purge gas to suppress oxidation and ice formation. Sample mass of 5 to 10 mg in a standard pan usually balances resolution and thermal lag; heavy fillers may need more mass and slower heating rates. Keep the cell clean, record cooling conditions together with heating data because thermal history controls crystallinity, and store the raw curves so that re-analysis with different limits remains possible.

How do I select the right Heat-Flux DSC for Polymer Analysis?

Choose heat-flux technology when samples are filled, opaque, inhomogeneous or simply inconvenient to prepare, and when the target transitions are strong, as in melting and crystallisation. Confirm the cooling accessory needed for your lowest working temperature and the crucible types for your sample chemistry. Specify whether oxidative induction time testing is required, because that determines the gas control package.

How does it compare with other DSC variants?

The first decision is cell type. Heat-flux cells cope with larger samples and give robust results in routine polymer QC; power-compensation cells offer faster response and better resolution of weak transitions, which helps in research on blends and thin films. Then fix the temperature range: below-ambient capability needs a liquid nitrogen or mechanical cooling accessory, while engineering polymers need a cell rated to at least 600 °C. Sensitivity matters when a weak glass transition in a highly filled compound must be detected, and an autosampler matters above roughly twenty samples per day. Where decomposition begins close to a melting or curing event, choose a simultaneous DSC-TGA instrument so mass loss and heat flow are recorded on the same sample.

Full specifications

Full specifications
Temperature range−150 to 600 °C with cooling accessory
Heating rate0.1–80 °C/min
Cooling rateUp to 50 °C/min with liquid nitrogen
Calorimetric accuracy±1% (indium)
Temperature accuracy±0.2 °C (indium)
Sensor typeDisc-type thermocouple array
Crucible volume40 µL standard, 100 µL optional
Purge gas flow20–50 mL/min
Typical sample mass5–15 mg
Power supply220 V, 50/60 Hz

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Batch verification of filled thermoplastics
  • Melting and crystallisation temperature checks
  • Oxidative induction time of polyolefin compounds
  • Cure studies on composite moulding compounds

Key features

  • Thermoelectric disc sensor with stable baseline
  • Temperature range from about −150 °C with cooling accessory
  • Accepts standard and large-volume crucibles
  • Switchable inert and oxidative purge gases
  • Tolerates filled and irregular polymer samples
  • Calibration kit with indium and zinc standards

Frequently asked questions about Heat-Flux DSC for Polymer Analysis

It can, but the weak step change may be hard to separate from a drifting baseline. Practical measures are to use a larger sample, a slower heating rate, a modulated temperature programme or a repeat scan after controlled cooling. Modulated DSC is often the more reliable option for highly filled compounds.

Related models

All DSC

Request a quotation for the Heat-Flux DSC for Polymer Analysis