Modulated-Temperature DSC for Polymer Analysis — product photo

Modulated-Temperature DSC for Polymer Analysis

聚合物分析用调制温度差示扫描量热仪

  • SKU DSCA-0003
  • DSC
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Temperature range−90 to 600 °C with cooling accessory
Underlying heating rate0.1–10 °C/min during modulation
Modulation amplitude0.1–3 °C
Modulation period20–200 s
Calorimetric accuracy±1% (indium)
Specific heat accuracy±2% at 25 °C
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 11357-1, ISO 11357-2, ISO 11357-3

What is the Modulated-Temperature DSC for Polymer Analysis?

A modulated-temperature DSC superimposes a small sinusoidal oscillation on a linear heating ramp and separates the response into reversing and non-reversing components. It resolves weak glass transitions hidden under overlapping melting or curing peaks in complex polymer systems.

What is the Modulated-Temperature DSC for Polymer Analysis?

A modulated-temperature DSC superimposes a small sinusoidal oscillation on a linear heating ramp and separates the response into reversing and non-reversing components. It resolves weak glass transitions hidden under overlapping melting or curing peaks in complex polymer systems.

Overview

In modulated DSC the average heating rate is combined with a periodic oscillation of amplitude typically 0.5 to 2 °C and period 40 to 100 seconds. Fourier analysis separates the heat-flow signal into a reversing part, which follows the instantaneous heating rate and reflects heat capacity such as glass transition and melting, and a non-reversing part associated with kinetic events such as crystallisation, cure, evaporation and enthalpy relaxation. The total signal equals the sum of the two, so a conventional curve is still available. This is valuable for thermosets where glass transition is buried under a cure exotherm, for aged polymers showing enthalpy relaxation near the glass transition, and for measuring heat capacity without a separate sapphire calibration. The technique requires stable cell performance and careful selection of oscillation parameters.

How does it work?

A DSC cell holds the sample and an empty reference pan on a common sensor plate inside a furnace programmed through a controlled temperature ramp. The instrument records the differential heat flow needed to keep sample and reference at the same temperature, in milliwatts, against the furnace temperature or time. Endothermic events such as melting and volatilisation appear as peaks, and exothermic events such as crystallisation and curing appear as positive deviations. Heat-flux cells measure the temperature difference across a thermoelectric disc, while power-compensation cells heat the two holders separately and record the power difference directly. Calibration uses the melting point and enthalpy of indium, and often zinc and tin, with a sapphire disc for specific-heat calibration. Purge gas, sample mass, pan type and heating rate all influence peak shape and the temperatures reported for polymers.

What are the key features?

  • Sinusoidal modulation superimposed on a linear ramp
  • Separation of reversing and non-reversing heat flow
  • Detection of glass transition under curing exotherms
  • Heat capacity measurement without a separate standard
  • Enthalpy relaxation studies on aged polymers
  • User-selectable amplitude and period

What are the technical specifications?

A typical modulated-temperature dsc for polymer analysis configuration offers temperature range of −90 to 600 °C with cooling accessory, underlying heating rate of 0.1–10 °C/min during modulation, modulation amplitude of 0.1–3 °C, modulation period of 20–200 s, calorimetric accuracy of ±1% (indium) and specific heat accuracy of ±2% at 25 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Modulated-Temperature DSC for Polymer Analysis is used in glass transition measurement in curing thermosets, enthalpy relaxation and ageing assessment, blend and composite transition analysis, specific heat determination of polymers and semi-crystalline polymer melting behaviour. Across the wider DSC class, laboratories also deploy it for glass transition and melting point determination of polymers, degree of crystallinity and crystallisation kinetics and cure monitoring of thermosetting resins.

Which standards and certifications apply?

Relevant standards and methods include ISO 11357-1, ISO 11357-2, ISO 11357-3, ASTM D3418, ASTM E1356, ASTM D3895 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Calibrate temperature and enthalpy with indium before each campaign, or at least monthly, and check the baseline with an empty pair of pans. Seal volatile or moisture-sensitive samples in hermetic pans and work with a dry inert purge gas to suppress oxidation and ice formation. Sample mass of 5 to 10 mg in a standard pan usually balances resolution and thermal lag; heavy fillers may need more mass and slower heating rates. Keep the cell clean, record cooling conditions together with heating data because thermal history controls crystallinity, and store the raw curves so that re-analysis with different limits remains possible.

How do I select the right Modulated-Temperature DSC for Polymer Analysis?

Choose modulated DSC when a glass transition must be quantified in a sample that also shows melting, curing or ageing effects, or when specific heat is required without extra calibration. Confirm that the instrument reports total, reversing and non-reversing curves separately and that the software can fit the modulation mathematically. Report the amplitude, period and underlying rate with every result, because these parameters change the split between the two components.

How does it compare with other DSC variants?

The first decision is cell type. Heat-flux cells cope with larger samples and give robust results in routine polymer QC; power-compensation cells offer faster response and better resolution of weak transitions, which helps in research on blends and thin films. Then fix the temperature range: below-ambient capability needs a liquid nitrogen or mechanical cooling accessory, while engineering polymers need a cell rated to at least 600 °C. Sensitivity matters when a weak glass transition in a highly filled compound must be detected, and an autosampler matters above roughly twenty samples per day. Where decomposition begins close to a melting or curing event, choose a simultaneous DSC-TGA instrument so mass loss and heat flow are recorded on the same sample.

Full specifications

Full specifications
Temperature range−90 to 600 °C with cooling accessory
Underlying heating rate0.1–10 °C/min during modulation
Modulation amplitude0.1–3 °C
Modulation period20–200 s
Calorimetric accuracy±1% (indium)
Specific heat accuracy±2% at 25 °C
Sensor typeHeat-flux disc sensor
Crucible volume40 µL, hermetic options
Purge gas flow20–50 mL/min
Data outputTotal, reversing and non-reversing curves

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Glass transition measurement in curing thermosets
  • Enthalpy relaxation and ageing assessment
  • Blend and composite transition analysis
  • Specific heat determination of polymers
  • Semi-crystalline polymer melting behaviour

Key features

  • Sinusoidal modulation superimposed on a linear ramp
  • Separation of reversing and non-reversing heat flow
  • Detection of glass transition under curing exotherms
  • Heat capacity measurement without a separate standard
  • Enthalpy relaxation studies on aged polymers
  • User-selectable amplitude and period

Frequently asked questions about Modulated-Temperature DSC for Polymer Analysis

Reversing heat flow follows the instantaneous heating rate and reflects heat capacity, so it contains glass transition and melting. Non-reversing heat flow reflects time-dependent processes such as crystallisation, curing, evaporation and enthalpy relaxation. Their sum is the total heat flow, which is equivalent to a conventional DSC curve.