Power-Compensation DSC for Polymer Analysis — product photo

Power-Compensation DSC for Polymer Analysis

聚合物分析用功率补偿型差示扫描量热仪

  • SKU DSCA-0002
  • DSC
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Temperature range−90 to 550 °C with cooling system
Heating rate0.1–200 °C/min
Cooling rateUp to 100 °C/min with mechanical cooling
Calorimetric accuracy±0.5% (indium)
Temperature accuracy±0.1 °C (indium)
Calorimetric precision±0.1%
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 11357-1, ISO 11357-2, ISO 11357-3

What is the Power-Compensation DSC for Polymer Analysis?

A power-compensation DSC heats the sample and reference holders independently and records the difference in electrical power required to keep them equal. Its fast response and high resolution make it suitable for weak transitions, thin films, blends and kinetic studies on small polymer samples.

What is the Power-Compensation DSC for Polymer Analysis?

A power-compensation DSC heats the sample and reference holders independently and records the difference in electrical power required to keep them equal. Its fast response and high resolution make it suitable for weak transitions, thin films, blends and kinetic studies on small polymer samples.

Overview

In a power-compensation cell the two holders are separate, low-mass furnaces, each with its own platinum resistance thermometer and heater, and the control loop adjusts power continuously so the two temperatures stay identical. The recorded signal is therefore power rather than temperature difference, which shortens the thermal path and gives a fast, nearly linear response. That short path produces narrow, well-resolved peaks and lets a small sample, sometimes 1 to 3 mg, show transitions that a heat-flux cell would smooth away. The penalty is greater sensitivity to sample contact, pan seating and purge flow, and a smaller maximum sample size. Sub-ambient operation requires a cooling system, and instrument design should be checked for the maximum heating rate you need in kinetic work.

How does it work?

A DSC cell holds the sample and an empty reference pan on a common sensor plate inside a furnace programmed through a controlled temperature ramp. The instrument records the differential heat flow needed to keep sample and reference at the same temperature, in milliwatts, against the furnace temperature or time. Endothermic events such as melting and volatilisation appear as peaks, and exothermic events such as crystallisation and curing appear as positive deviations. Heat-flux cells measure the temperature difference across a thermoelectric disc, while power-compensation cells heat the two holders separately and record the power difference directly. Calibration uses the melting point and enthalpy of indium, and often zinc and tin, with a sapphire disc for specific-heat calibration. Purge gas, sample mass, pan type and heating rate all influence peak shape and the temperatures reported for polymers.

What are the key features?

  • Separately controlled sample and reference micro-furnaces
  • Direct power-difference measurement in milliwatts
  • Resolution of weak transitions in small samples
  • Fast response suitable for kinetic studies
  • Supports modulated heating programmes
  • Small sample capability from about 1 mg

What are the technical specifications?

A typical power-compensation dsc for polymer analysis configuration offers temperature range of −90 to 550 °C with cooling system, heating rate of 0.1–200 °C/min, cooling rate of Up to 100 °C/min with mechanical cooling, calorimetric accuracy of ±0.5% (indium), temperature accuracy of ±0.1 °C (indium) and calorimetric precision of ±0.1%. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Power-Compensation DSC for Polymer Analysis is used in thin film and coating transition analysis, polymer blend miscibility studies, crystallisation kinetics of small samples, copolymer composition research and high-resolution specific heat measurement. Across the wider DSC class, laboratories also deploy it for glass transition and melting point determination of polymers, degree of crystallinity and crystallisation kinetics and cure monitoring of thermosetting resins.

Which standards and certifications apply?

Relevant standards and methods include ISO 11357-1, ISO 11357-2, ISO 11357-3, ASTM D3418, ASTM E1356, ASTM D3895 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Calibrate temperature and enthalpy with indium before each campaign, or at least monthly, and check the baseline with an empty pair of pans. Seal volatile or moisture-sensitive samples in hermetic pans and work with a dry inert purge gas to suppress oxidation and ice formation. Sample mass of 5 to 10 mg in a standard pan usually balances resolution and thermal lag; heavy fillers may need more mass and slower heating rates. Keep the cell clean, record cooling conditions together with heating data because thermal history controls crystallinity, and store the raw curves so that re-analysis with different limits remains possible.

How do I select the right Power-Compensation DSC for Polymer Analysis?

Select power compensation when transitions are weak or closely spaced, when the available sample mass is very small, or when heating rates above 100 °C per minute are needed for kinetics. Because the cell is sensitive to sample seating, plan careful sample preparation and check repeatability with a reference polymer. Confirm the mechanical cooling system, since many polymer programmes need controlled cooling as well as controlled heating.

How does it compare with other DSC variants?

The first decision is cell type. Heat-flux cells cope with larger samples and give robust results in routine polymer QC; power-compensation cells offer faster response and better resolution of weak transitions, which helps in research on blends and thin films. Then fix the temperature range: below-ambient capability needs a liquid nitrogen or mechanical cooling accessory, while engineering polymers need a cell rated to at least 600 °C. Sensitivity matters when a weak glass transition in a highly filled compound must be detected, and an autosampler matters above roughly twenty samples per day. Where decomposition begins close to a melting or curing event, choose a simultaneous DSC-TGA instrument so mass loss and heat flow are recorded on the same sample.

Full specifications

Full specifications
Temperature range−90 to 550 °C with cooling system
Heating rate0.1–200 °C/min
Cooling rateUp to 100 °C/min with mechanical cooling
Calorimetric accuracy±0.5% (indium)
Temperature accuracy±0.1 °C (indium)
Calorimetric precision±0.1%
Sensor typeDual platinum resistance thermometers
Crucible volume20–40 µL
Typical sample mass1–5 mg
Purge gas flow10–50 mL/min

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Thin film and coating transition analysis
  • Polymer blend miscibility studies
  • Crystallisation kinetics of small samples
  • Copolymer composition research
  • High-resolution specific heat measurement

Key features

  • Separately controlled sample and reference micro-furnaces
  • Direct power-difference measurement in milliwatts
  • Resolution of weak transitions in small samples
  • Fast response suitable for kinetic studies
  • Supports modulated heating programmes
  • Small sample capability from about 1 mg

Frequently asked questions about Power-Compensation DSC for Polymer Analysis

The cell keeps the sample and reference holders at identical temperature, and a large sample would create an internal temperature gradient that the control loop cannot compensate. Small samples of 1 to 3 mg keep the thermal gradient negligible, which is what makes the high resolution and fast response possible.