High-Temperature DSC for Engineering Polymers

工程塑料用高温差示扫描量热仪

  • SKU DSCA-0006
  • DSC
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety compliance (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Temperature rangeAmbient to 1500 °C (optional 1600 °C)
Heating rate0.1–50 °C/min
Temperature accuracy±2 °C at 1000 °C
Calorimetric accuracy±3% for metal standards
Sensor typePlatinum or platinum-rhodium thermocouples
Sample holder materialAlumina, platinum or ceramic crucibles
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 11357-1, ISO 11357-2, ISO 11357-3

What is the High-Temperature DSC for Engineering Polymers?

A high-temperature DSC extends the cell to about 1600 °C so that engineering and high-performance polymers, composites and their inorganic fillers can be characterised in one instrument. It is specified when polyimide, polyether ether ketone or ceramic-filled systems exceed ordinary cell limits.

What is the High-Temperature DSC for Engineering Polymers?

A high-temperature DSC extends the cell to about 1600 °C so that engineering and high-performance polymers, composites and their inorganic fillers can be characterised in one instrument. It is specified when polyimide, polyether ether ketone or ceramic-filled systems exceed ordinary cell limits.

Overview

High-temperature operation requires a furnace with platinum or platinum-rhodium windings, ceramic or platinum sample holders, a purge system that excludes oxygen and a temperature sensor able to withstand repeated cycling. Cells of this class typically cover ambient to 1500 or 1600 °C and are used for polyimides, liquid crystal polymers, polybenzimidazole and composite systems whose transitions or decomposition lie above the range of standard cells. The same instrument can also verify inorganic fillers and glass fibres by melting point, which reduces the number of separate runs in a materials laboratory. Because melting metals such as zinc, gold or a certified alloy are available as calibration standards over this range, traceability can be maintained with reference materials that bracket the working temperatures, and the calibration procedure should be documented accordingly.

How does it work?

A DSC cell holds the sample and an empty reference pan on a common sensor plate inside a furnace programmed through a controlled temperature ramp. The instrument records the differential heat flow needed to keep sample and reference at the same temperature, in milliwatts, against the furnace temperature or time. Endothermic events such as melting and volatilisation appear as peaks, and exothermic events such as crystallisation and curing appear as positive deviations. Heat-flux cells measure the temperature difference across a thermoelectric disc, while power-compensation cells heat the two holders separately and record the power difference directly. Calibration uses the melting point and enthalpy of indium, and often zinc and tin, with a sapphire disc for specific-heat calibration. Purge gas, sample mass, pan type and heating rate all influence peak shape and the temperatures reported for polymers.

What are the key features?

  • Furnace rated to about 1500–1600 °C
  • Platinum or ceramic sample holders
  • Oxygen-excluding purge for high-temperature scans
  • Metal melting point calibration across the range
  • Supports composite and filled polymer analysis
  • Protective gas for sensor longevity

What are the technical specifications?

A typical high-temperature dsc for engineering polymers configuration offers temperature range of Ambient to 1500 °C (optional 1600 °C), heating rate of 0.1–50 °C/min, temperature accuracy of ±2 °C at 1000 °C, calorimetric accuracy of ±3% for metal standards, sensor type of Platinum or platinum-rhodium thermocouples and sample holder material of Alumina, platinum or ceramic crucibles. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The High-Temperature DSC for Engineering Polymers is used in polyimide and high-performance polymer transitions, composite matrix cure and decomposition studies, melting behaviour of inorganic fillers and fibres, glass and ceramic filler verification and thermal stability of heat-resistant coatings. Across the wider DSC class, laboratories also deploy it for glass transition and melting point determination of polymers, degree of crystallinity and crystallisation kinetics and cure monitoring of thermosetting resins.

Which standards and certifications apply?

Relevant standards and methods include ISO 11357-1, ISO 11357-2, ISO 11357-3, ASTM D3418, ASTM E1356, ASTM D3895 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety compliance; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Calibrate temperature and enthalpy with indium before each campaign, or at least monthly, and check the baseline with an empty pair of pans. Seal volatile or moisture-sensitive samples in hermetic pans and work with a dry inert purge gas to suppress oxidation and ice formation. Sample mass of 5 to 10 mg in a standard pan usually balances resolution and thermal lag; heavy fillers may need more mass and slower heating rates. Keep the cell clean, record cooling conditions together with heating data because thermal history controls crystallinity, and store the raw curves so that re-analysis with different limits remains possible.

How do I select the right High-Temperature DSC for Engineering Polymers?

Specify a high-temperature cell only when the working temperatures genuinely exceed 600 °C, because platinum hardware and protective atmospheres increase both cost and maintenance. Confirm the calibration standards available over your working range and the maximum cooling rate, since high-temperature furnaces cool slowly and long cycles reduce throughput. Ask for the recommended purge gas and the sensor replacement interval in an RFQ.

How does it compare with other DSC variants?

The first decision is cell type. Heat-flux cells cope with larger samples and give robust results in routine polymer QC; power-compensation cells offer faster response and better resolution of weak transitions, which helps in research on blends and thin films. Then fix the temperature range: below-ambient capability needs a liquid nitrogen or mechanical cooling accessory, while engineering polymers need a cell rated to at least 600 °C. Sensitivity matters when a weak glass transition in a highly filled compound must be detected, and an autosampler matters above roughly twenty samples per day. Where decomposition begins close to a melting or curing event, choose a simultaneous DSC-TGA instrument so mass loss and heat flow are recorded on the same sample.

Full specifications

Full specifications
Temperature rangeAmbient to 1500 °C (optional 1600 °C)
Heating rate0.1–50 °C/min
Temperature accuracy±2 °C at 1000 °C
Calorimetric accuracy±3% for metal standards
Sensor typePlatinum or platinum-rhodium thermocouples
Sample holder materialAlumina, platinum or ceramic crucibles
Typical sample mass10–50 mg
Atmosphere controlArgon or nitrogen purge, oxygen option
Purge gas flow20–100 mL/min
CoolingForced air or water cooled furnace

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Polyimide and high-performance polymer transitions
  • Composite matrix cure and decomposition studies
  • Melting behaviour of inorganic fillers and fibres
  • Glass and ceramic filler verification
  • Thermal stability of heat-resistant coatings

Key features

  • Furnace rated to about 1500–1600 °C
  • Platinum or ceramic sample holders
  • Oxygen-excluding purge for high-temperature scans
  • Metal melting point calibration across the range
  • Supports composite and filled polymer analysis
  • Protective gas for sensor longevity

Frequently asked questions about High-Temperature DSC for Engineering Polymers

Metals and certified alloys with well-known melting points bracket the range: indium and tin at lower temperatures, then aluminium, silver, gold and nickel up to about 1454 °C. Laboratories should use at least two standards that bracket the working temperature and document the calibration curve, because sensitivity drifts across such a wide range.