Melt Flow Analysis

塑料熔体流动分析仪

MFA · Plastic Analysis Equipment · 6 models

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 1133-1, ASTM D1238, ASTM D3364

Standards referenced

  • ISO 1133-1
  • ASTM D1238
  • ASTM D3364
  • GB/T 3682.1
  • GB/T 3682.2
  • IEC 61010-1

What are Melt Flow Analysis?

Melt flow analysis determines how a molten thermoplastic flows through a standard die under a specified load, expressed as melt mass-flow rate, melt volume-flow rate or melt density. The result indexes processability, lot-to-lot consistency and the effect of fillers or recycling on a plastic grade.

6 models of Melt Flow Analysis

The 6 models below are current configurations; specifications are confirmed on quotation.

Gravimetric Melt Flow Rate Analyzer

重量法熔体流动速率分析仪

  • MFA-0001
  • Melt Flow Analysis
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Temperature range:
50–400 °C
Temperature accuracy:
±0.2 °C
Load weights:
0.325 / 1.2 / 2.16 / 5 / 10 / 21.6 kg
Die dimensions:
Ø 2.095 mm × 8.000 mm
Barrel bore:
9.55 mm
Cut interval:
10–60 s, operator controlled

A gravimetric analyzer cuts extrudate at timed intervals and weighs it to obtain the melt mass-flow rate directly, exactly as the reference method prescribes. It is the most straightforward way to demonstrate compliance with ISO 1133 or ASTM D1238.

Request a quote
View details

Automated Melt Index Analyzer with Robotic Sample Handling

带机器人取样的自动熔融指数分析仪

  • MFA-0002
  • Melt Flow Analysis
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety compliance (to be confirmed)
Measurement barrels:
1 or 2
Temperature range:
50–400 °C
Temperature accuracy:
±0.2 °C
Tray capacity:
20–60 sample positions
Cycle time per sample:
15–30 min including preheat
Load weights:
1.2 / 2.16 / 5 / 10 / 21.6 kg

A robotic melt index analyzer loads weighed sample portions, starts the preheat cycle, cuts and transfers extrudate to a balance without operator involvement. It is used where large sample numbers and traceable automated records are required.

Request a quote
View details

Multi-Position Melt Flow Analyzer

多工位熔体流动分析仪

  • MFA-0003
  • Melt Flow Analysis
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Number of positions:
2–6
Temperature range:
50–400 °C per position
Temperature accuracy:
±0.2 °C
Die dimensions:
Ø 2.095 mm × 8.0 mm per position
Load weights:
1.2 / 2.16 / 5 / 10 / 21.6 kg
Preheat timer:
0–9999 s per position

A multi-position melt flow analyzer contains several independently heated barrels that measure different samples, grades or conditions in parallel. It is chosen when a laboratory must compare many plastic lots within one shift.

Request a quote
View details

Melt Density Analyzer for Thermoplastics

热塑性塑料熔体密度测定仪

  • MFA-0004
  • Melt Flow Analysis
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Melt density range:
0.6–1.5 g/cm³ typical
Displacement resolution:
0.01 mm
Temperature range:
50–400 °C
Temperature accuracy:
±0.2 °C
Balance resolution:
0.1 mg
Load weights:
2.16 / 5 / 10 / 21.6 kg

A melt density analyzer determines the density of a polymer melt at the test temperature from the ratio of mass-flow rate to volume-flow rate. It is used to control filler loading and to explain flow-rate differences between lots.

Request a quote
View details

Melt Flow Analyzer for Filled and Reinforced Plastics

填充与增强塑料熔体流动分析仪

  • MFA-0005
  • Melt Flow Analysis
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Die material:
Hardened tool steel or tungsten carbide
Temperature range:
50–400 °C
Load weights:
2.16 / 5 / 10 / 21.6 kg
Die options:
Ø 2.095 mm standard, larger on request
Barrel liner:
Wear-resistant alloy, replaceable
Temperature accuracy:
±0.2 °C

An analyzer configured for filled and reinforced plastics uses abrasion-resistant dies and barrels and a temperature range suited to stiff, highly loaded compounds. It measures flow behaviour of materials that would damage standard hardware or block a die.

Request a quote
View details

High-Load Melt Flow Analyzer for High-Viscosity Plastics

高黏度塑料用高负荷熔体流动分析仪

  • MFA-0006
  • Melt Flow Analysis
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Available loads:
10 / 21.6 kg standard, higher on request
Temperature range:
50–400 °C
Temperature accuracy:
±0.2 °C
Temperature stability:
±0.1 °C over 30 min
Die dimensions:
Ø 2.095 mm × 8.0 mm
Frame load capacity:
Designed for continuous 21.6 kg load

A high-load analyzer applies weights up to 21.6 kg and above to move very stiff melts, such as pipe grades, ultra-high-molecular-weight polyethylene and highly filled compounds. It is specified when standard loads produce no measurable flow within the allowed time.

Request a quote
View details

Compare Melt Flow Analysis models

ModelTemperature rangeTemperature accuracyLoad weightsDie dimensionsSample mass per test
Gravimetric Melt Flow Rate AnalyzerMFA-000150–400 °C±0.2 °C0.325 / 1.2 / 2.16 / 5 / 10 / 21.6 kgØ 2.095 mm × 8.000 mm3–8 g
Automated Melt Index Analyzer with Robotic Sample HandlingMFA-000250–400 °C±0.2 °C1.2 / 2.16 / 5 / 10 / 21.6 kg——
Multi-Position Melt Flow AnalyzerMFA-000350–400 °C per position±0.2 °C1.2 / 2.16 / 5 / 10 / 21.6 kgØ 2.095 mm × 8.0 mm per position—
Melt Density Analyzer for ThermoplasticsMFA-000450–400 °C±0.2 °C2.16 / 5 / 10 / 21.6 kgØ 2.095 mm × 8.0 mm—
Melt Flow Analyzer for Filled and Reinforced PlasticsMFA-000550–400 °C±0.2 °C2.16 / 5 / 10 / 21.6 kg—4–10 g
High-Load Melt Flow Analyzer for High-Viscosity PlasticsMFA-000650–400 °C±0.2 °C—Ø 2.095 mm × 8.0 mm5–12 g

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do Melt Flow Analysis work?

The method heats a plastic sample in a barrel of defined bore, compacts it with a piston and extrudes it through a die of defined diameter and length under a controlled load. Mass-flow rate is obtained by weighing extrudate cut over a known time, and volume-flow rate by recording piston displacement with an encoder. Dividing mass flow by volume flow gives melt density at the test temperature, which is a useful check on filler loading and on batch consistency. Temperature, load, die geometry and preheat time are fixed by the standard condition applicable to the plastic, so results from different laboratories are comparable only when the same condition letter is used. Comparative testing, where a reference material is run on the same instrument, is often the most practical way to confirm instrument condition.

Which Melt Flow Analysis variants are available?

  • Gravimetric Melt Flow Rate Analyzer — A gravimetric analyzer cuts extrudate at timed intervals and weighs it to obtain the melt mass-flow rate directly, exactly as the reference method prescribes.
  • Automated Melt Index Analyzer with Robotic Sample Handling — A robotic melt index analyzer loads weighed sample portions, starts the preheat cycle, cuts and transfers extrudate to a balance without operator involvement.
  • Multi-Position Melt Flow Analyzer — A multi-position melt flow analyzer contains several independently heated barrels that measure different samples, grades or conditions in parallel.
  • Melt Density Analyzer for Thermoplastics — A melt density analyzer determines the density of a polymer melt at the test temperature from the ratio of mass-flow rate to volume-flow rate.
  • Melt Flow Analyzer for Filled and Reinforced Plastics — An analyzer configured for filled and reinforced plastics uses abrasion-resistant dies and barrels and a temperature range suited to stiff, highly loaded compounds.
  • High-Load Melt Flow Analyzer for High-Viscosity Plastics — A high-load analyzer applies weights up to 21.6 kg and above to move very stiff melts, such as pipe grades, ultra-high-molecular-weight polyethylene and highly filled compounds.

How do I choose the right variant?

Define the output you need first. For routine lot release, a gravimetric instrument that weighs timed cuts is adequate and easiest to defend against the standard. When results must be traceable in a digital system or the material is difficult to cut, an instrument with piston displacement measurement is preferable. Where throughput dominates, choose a multi-position analyzer or a robotic loading configuration. Add a melt density capability when filler content or batch-to-batch density variation is a quality concern. For filled, reinforced or very high molecular weight plastics, specify the load set and a corrosion- or abrasion-resistant barrel and die, because standard hardware may not reach the required condition or may wear quickly.

Where are Melt Flow Analysis used?

Melt Flow Analysis are specified in lot release of polyethylene and polypropylene grades, verification of recycled plastic melt flow consistency, effect of filler and reinforcement on flow behaviour, incoming inspection at extrusion and moulding plants, melt density checks for filler loading control and comparison of suppliers for the same nominal grade.

Which standards and certifications apply?

Work with Melt Flow Analysis is commonly governed by ISO 1133-1, ASTM D1238, ASTM D3364, GB/T 3682.1, GB/T 3682.2 and IEC 61010-1. Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

Level the instrument and allow full thermal equilibration before the first measurement, then verify barrel temperature with an external probe. Check die bore and length against the standard tolerance and replace worn dies, because an enlarged bore lowers the measured value. Use only dried material for hygroscopic plastics stated in the method, and discard any extrudate containing bubbles or voids. Clean the barrel between materials with purging compound, not with metal tools. Keep weights traceable and record the standard condition, sample mass, preheat time and any melt density value with every result so that a reviewer can reconstruct the test.

Frequently asked questions about Melt Flow Analysis

It indicates how easily the grade flows at the test condition, which correlates with processability: a high value suits thin-wall or complex mouldings, a low value suits extrusion of thick sections and gives better melt strength. Because it is sensitive to molecular weight and filler content, it also serves as a lot-to-lot consistency check.