Multi-Position Melt Flow Analyzer
多工位熔体流动分析仪
- SKU MFA-0003
- Melt Flow Analysis
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Number of positions | 2–6 |
|---|---|
| Temperature range | 50–400 °C per position |
| Temperature accuracy | ±0.2 °C |
| Die dimensions | Ø 2.095 mm × 8.0 mm per position |
| Load weights | 1.2 / 2.16 / 5 / 10 / 21.6 kg |
| Preheat timer | 0–9999 s per position |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 1133-1, ASTM D1238, ASTM D3364
What is the Multi-Position Melt Flow Analyzer?
A multi-position melt flow analyzer contains several independently heated barrels that measure different samples, grades or conditions in parallel. It is chosen when a laboratory must compare many plastic lots within one shift.
What is the Multi-Position Melt Flow Analyzer?
A multi-position melt flow analyzer contains several independently heated barrels that measure different samples, grades or conditions in parallel. It is chosen when a laboratory must compare many plastic lots within one shift.
Overview
Each position has its own barrel, die, heater band and temperature loop, and may have its own piston and weight lifting mechanism, so materials at different test temperatures can be run simultaneously without thermal interference. A shared control interface configures all positions, and a common evaluation module applies the same calculation to each result. Throughput gains are substantial: four positions running in parallel complete four measurements in the time a single barrel completes one, ignoring preheat, which is exactly what batch release work needs. Heaters are insulated from each other and from the frame so that changing a setpoint on one position does not disturb another. Before acceptance, a reference polymer should be measured on each position to confirm that results agree within the expected repeatability.
How does it work?
The method heats a plastic sample in a barrel of defined bore, compacts it with a piston and extrudes it through a die of defined diameter and length under a controlled load. Mass-flow rate is obtained by weighing extrudate cut over a known time, and volume-flow rate by recording piston displacement with an encoder. Dividing mass flow by volume flow gives melt density at the test temperature, which is a useful check on filler loading and on batch consistency. Temperature, load, die geometry and preheat time are fixed by the standard condition applicable to the plastic, so results from different laboratories are comparable only when the same condition letter is used. Comparative testing, where a reference material is run on the same instrument, is often the most practical way to confirm instrument condition.
What are the key features?
- Two to six independently controlled positions
- Separate die and piston per position
- Shared interface with per-position programming
- Thermal insulation between positions
- Automatic or manual cutting per position
- Central result table comparing all positions
What are the technical specifications?
A typical multi-position melt flow analyzer configuration offers number of positions of 2–6, temperature range of 50–400 °C per position, temperature accuracy of ±0.2 °C, die dimensions of Ø 2.095 mm × 8.0 mm per position, load weights of 1.2 / 2.16 / 5 / 10 / 21.6 kg and preheat timer of 0–9999 s per position. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Multi-Position Melt Flow Analyzer is used in parallel comparison of production lots, multi-temperature testing in one run, bulk incoming inspection at converters and round-robin data collection for process control. Across the wider Melt Flow Analysis class, laboratories also deploy it for lot release of polyethylene and polypropylene grades, verification of recycled plastic melt flow consistency and effect of filler and reinforcement on flow behaviour.
Which standards and certifications apply?
Relevant standards and methods include ISO 1133-1, ASTM D1238, ASTM D3364, GB/T 3682.1, GB/T 3682.2 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Level the instrument and allow full thermal equilibration before the first measurement, then verify barrel temperature with an external probe. Check die bore and length against the standard tolerance and replace worn dies, because an enlarged bore lowers the measured value. Use only dried material for hygroscopic plastics stated in the method, and discard any extrudate containing bubbles or voids. Clean the barrel between materials with purging compound, not with metal tools. Keep weights traceable and record the standard condition, sample mass, preheat time and any melt density value with every result so that a reviewer can reconstruct the test.
How do I select the right Multi-Position Melt Flow Analyzer?
Specify a multi-position analyzer when the bottleneck is barrel availability rather than operator time, which typically happens above twenty measurements per shift. Choose the number of positions from the distinct test conditions you run, not simply from the sample count, and confirm each position has an independent temperature loop. Require a per-position reference-material check as part of acceptance testing.
How does it compare with other Melt Flow Analysis variants?
Define the output you need first. For routine lot release, a gravimetric instrument that weighs timed cuts is adequate and easiest to defend against the standard. When results must be traceable in a digital system or the material is difficult to cut, an instrument with piston displacement measurement is preferable. Where throughput dominates, choose a multi-position analyzer or a robotic loading configuration. Add a melt density capability when filler content or batch-to-batch density variation is a quality concern. For filled, reinforced or very high molecular weight plastics, specify the load set and a corrosion- or abrasion-resistant barrel and die, because standard hardware may not reach the required condition or may wear quickly.
Full specifications
| Number of positions | 2–6 |
|---|---|
| Temperature range | 50–400 °C per position |
| Temperature accuracy | ±0.2 °C |
| Die dimensions | Ø 2.095 mm × 8.0 mm per position |
| Load weights | 1.2 / 2.16 / 5 / 10 / 21.6 kg |
| Preheat timer | 0–9999 s per position |
| Throughput | Up to 6 samples per run |
| Data output | Per-position curves and summary table |
| Power | 2–6 kW |
| Weight | 100–250 kg |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Parallel comparison of production lots
- Multi-temperature testing in one run
- Bulk incoming inspection at converters
- Round-robin data collection for process control
Key features
- Two to six independently controlled positions
- Separate die and piston per position
- Shared interface with per-position programming
- Thermal insulation between positions
- Automatic or manual cutting per position
- Central result table comparing all positions
Frequently asked questions about Multi-Position Melt Flow Analyzer
Yes. Each barrel has its own heater, sensor and control loop, so temperature verification and a reference-material test are required per position. Many laboratories rotate which position is checked in detail and verify all positions at the annual calibration, but results should always be recorded per position.
That depends on the design. Positions with individual weight lifting and piston handling can run different loads simultaneously, while positions sharing a weight mechanism cannot. If your test matrix mixes loads, this should be specified at the time of purchase, since it is not always available as a retrofit.
There are simply more dies, heaters and sensors to maintain, and a single failed heater affects only one position, which can be overlooked if results are not reviewed per position. Cleaning takes longer because each barrel must be purged separately, and a blockage on one position should always be recorded in the maintenance log.
It indicates how easily the grade flows at the test condition, which correlates with processability: a high value suits thin-wall or complex mouldings, a low value suits extrusion of thick sections and gives better melt strength. Because it is sensitive to molecular weight and filler content, it also serves as a lot-to-lot consistency check.
Melt density is obtained by dividing the mass-flow rate by the volume-flow rate, both measured at the same condition. It changes if filler loading, polymer grade or additive content changes, so it provides an independent check that a flow-rate difference is caused by molecular structure rather than by a formulation change.
Grind or use a representative portion of the compound, dry it if the base resin requires it, and expect poorer repeatability because filler particles disturb flow and may block the die. Report the filler content with the result and consider abrasive-resistant dies, since fillers such as glass fibre wear the die land and change the geometry.