What are Western Blot Systems?

Western blot systems transfer proteins from a gel onto a membrane and process the membrane through blocking, antibody incubation and detection, allowing specific proteins to be identified and quantified. They are used in protein research, biopharmaceutical quality control and diagnostic laboratories.

5 models of Western Blot Systems

The 5 models below are current configurations; specifications are confirmed on quotation.

Automated Capillary Western Blot System

自动化毛细管 Western 印迹系统

  • WBS-0001
  • Western Blot Systems
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
Capillaries per cartridge:
12, 24, 48 or 96
Run time:
approx. 3–5 h
Sample volume:
0.5–5 µL per capillary
Protein concentration:
0.2–2 mg/mL total protein (typical)
Molecular weight range:
approx. 12–440 kDa
Separation:
Capillary electrophoresis in photoactivated matrix

An automated capillary western blot system separates proteins in a capillary and performs blocking, antibody incubation and detection inside the same capillary, quantifying results as peak areas. It replaces manual gels and membranes with a few hours of hands-off operation.

Request a quote
View details

Semi-Dry Western Blot Transfer System

半干转印系统

  • WBS-0002
  • Western Blot Systems
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
Gel capacity:
1–4 mini or midi gels
Transfer time:
approx. 15–60 min
Maximum current:
up to 400 mA (model dependent)
Maximum voltage:
up to 30 V
Electrode area:
approx. 150 x 150 mm
Buffer volume:
approx. 20–60 mL per transfer

A semi-dry transfer system places the gel and membrane between flat plate electrodes with only a few buffer-soaked filter pads, completing transfer in 15 to 60 minutes with minimal buffer. It suits routine blotting of mini and midi gels.

Request a quote
View details

Tank Transfer Blotting System

槽式转印系统

  • WBS-0003
  • Western Blot Systems
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
Gel formats:
Mini (8 x 10 cm), midi and large (16 x 20 cm)
Cassette capacity:
1–4 cassettes (model dependent)
Transfer time:
approx. 60–120 min at 100 V, or overnight at 30–40 V
Maximum voltage:
up to 200 V
Maximum current:
up to 2 A (model dependent)
Buffer volume:
approx. 500–3,000 mL

A tank transfer system immerses the gel and membrane cassette in buffer with plate electrodes on each side, giving high and reproducible transfer efficiency for proteins from 10 to over 200 kDa. It is the standard method for large gels and high molecular weight targets.

Request a quote
View details

Vacuum Transfer Blotting Apparatus

真空转印仪

  • WBS-0004
  • Western Blot Systems
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
Blot area:
approx. 100 x 100 to 200 x 200 mm
Transfer time:
approx. 30–60 min
Vacuum range:
approx. −10 to −50 kPa (adjustable)
Voltage assist:
up to 60 V
Buffer volume:
approx. 100–300 mL
Gel thickness:
0.5–3 mm

A vacuum transfer apparatus draws buffer through the gel and membrane using a vacuum manifold, transferring proteins in 30 to 60 minutes with even pressure across the blot. It is used for thick gels and for efficient elution of high molecular weight proteins.

Request a quote
View details

Automated Western Blot Incubation System

自动化 Western 印迹孵育系统

  • WBS-0005
  • Western Blot Systems
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
Membranes per run:
1–6 (model dependent)
Antibody volume:
1–5 mL per membrane
Incubation time range:
1 min to overnight
Temperature control:
ambient to 40 °C
Agitation:
Rocking or orbital, 5–60 rpm
Wash steps:
Programmable, up to 10 repetitions

An automated incubation system performs blocking, antibody incubation and washing on membranes in a programmable tray or cassette, replacing manual shaking trays, reducing antibody consumption and improving consistency between blots in routine laboratories.

Request a quote
View details

Compare Western Blot Systems models

ModelDimensions (W x D x H)Transfer timeMaximum currentMaximum voltageBuffer volume
Automated Capillary Western Blot SystemWBS-0001approx. 500 x 500 x 450 mm————
Semi-Dry Western Blot Transfer SystemWBS-0002approx. 250 x 200 x 100 mmapprox. 15–60 minup to 400 mA (model dependent)up to 30 Vapprox. 20–60 mL per transfer
Tank Transfer Blotting SystemWBS-0003approx. 200 x 200 x 200 mmapprox. 60–120 min at 100 V, or overnight at 30–40 Vup to 2 A (model dependent)up to 200 Vapprox. 500–3,000 mL
Vacuum Transfer Blotting ApparatusWBS-0004approx. 350 x 300 x 200 mmapprox. 30–60 min——approx. 100–300 mL
Automated Western Blot Incubation SystemWBS-0005approx. 400 x 350 x 250 mm————

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do Western Blot Systems work?

Western blotting starts with separation of proteins by SDS-PAGE or a capillary system. In conventional blotting, the gel is placed against a nitrocellulose or PVDF membrane in a transfer stack and an electric field drives the negatively charged proteins out of the gel onto the membrane, where they bind by hydrophobic and electrostatic interaction. The membrane is then blocked with protein or detergent to saturate remaining binding sites, incubated with a primary antibody against the target, washed, incubated with an enzyme- or fluorophore-labelled secondary antibody that recognises the primary antibody, and washed again. Bound enzyme is detected by adding a chemiluminescent or colorimetric substrate, and the signal is imaged and quantified against a standard or a loading control. Automated capillary systems perform the equivalent steps in a capillary with a separation matrix and immobilised reagents.

Which Western Blot Systems variants are available?

  • Automated Capillary Western Blot System — An automated capillary western blot system separates proteins in a capillary and performs blocking, antibody incubation and detection inside the same capillary, quantifying results as peak areas.
  • Semi-Dry Western Blot Transfer System — A semi-dry transfer system places the gel and membrane between flat plate electrodes with only a few buffer-soaked filter pads, completing transfer in 15 to 60 minutes with minimal buffer.
  • Tank Transfer Blotting System — A tank transfer system immerses the gel and membrane cassette in buffer with plate electrodes on each side, giving high and reproducible transfer efficiency for proteins from 10 to over 200 kDa.
  • Vacuum Transfer Blotting Apparatus — A vacuum transfer apparatus draws buffer through the gel and membrane using a vacuum manifold, transferring proteins in 30 to 60 minutes with even pressure across the blot.
  • Automated Western Blot Incubation System — An automated incubation system performs blocking, antibody incubation and washing on membranes in a programmable tray or cassette, replacing manual shaking trays, reducing antibody consumption and improving consistency between blots in routine laboratories.

How do I choose the right variant?

Choose first between conventional and automated blotting. Conventional tank or semi-dry transfer with manual antibody incubation costs less per sample and allows flexible antibody choices, but requires more hands-on time and gives semi-quantitative results. Automated capillary systems reduce run time to a few hours, use nanolitre sample volumes and produce quantitative peak areas, which suits regulated laboratories generating many comparable data sets. For conventional workflows, decide transfer format by gel size and protein molecular weight: tank transfer suits large gels and high molecular weight proteins, semi-dry transfer is faster and uses less buffer, and vacuum transfer is useful for thick gels. Check membrane and gel dimensions, electrode type, current and voltage range, cooling options and whether the system handles multiple gels at once.

Where are Western Blot Systems used?

Western Blot Systems are specified in specific protein detection in cell lysates, recombinant protein expression monitoring, biopharmaceutical purity and identity testing, phosphorylation and signalling pathway studies and antibody validation and quality control.

Which standards and certifications apply?

Work with Western Blot Systems is commonly governed by USP <1057>, Ph. Eur. 2.2.31, IEC 61010-1, ISO 17025, 21 CFR Part 11 and ISO 9001. Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

Transfer efficiency depends on current, time, buffer composition and the amount of methanol or SDS, so conditions should be established for each target protein and recorded in the method. Air bubbles trapped in the stack cause localised transfer gaps, and membranes must be handled with gloves and kept wet once activated. Blocking agent choice affects background and antibody binding, and milk-based blockers can interfere with phospho-specific antibodies. Wash volumes and times must be consistent to keep background low. Chemiluminescent substrates fade quickly, so images should be captured within the recommended window, and quantitative comparisons should include a loading control on the same membrane. Store antibodies in aliquots at the recommended temperature and record lot numbers, because antibody performance varies between lots.

Frequently asked questions about Western Blot Systems

An electric field drives negatively charged SDS-coated proteins out of the gel and onto a nitrocellulose or PVDF membrane placed against it. Proteins bind the membrane by hydrophobic and electrostatic interactions, after which antibodies detect the target.