Tank Transfer Blotting System
槽式转印系统
- SKU WBS-0003
- Western Blot Systems
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IEC 61010-1 safety (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Gel formats | Mini (8 x 10 cm), midi and large (16 x 20 cm) |
|---|---|
| Cassette capacity | 1–4 cassettes (model dependent) |
| Transfer time | approx. 60–120 min at 100 V, or overnight at 30–40 V |
| Maximum voltage | up to 200 V |
| Maximum current | up to 2 A (model dependent) |
| Buffer volume | approx. 500–3,000 mL |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <1057>, Ph. Eur. 2.2.31, IEC 61010-1
What is the Tank Transfer Blotting System?
A tank transfer system immerses the gel and membrane cassette in buffer with plate electrodes on each side, giving high and reproducible transfer efficiency for proteins from 10 to over 200 kDa. It is the standard method for large gels and high molecular weight targets.
What is the Tank Transfer Blotting System?
A tank transfer system immerses the gel and membrane cassette in buffer with plate electrodes on each side, giving high and reproducible transfer efficiency for proteins from 10 to over 200 kDa. It is the standard method for large gels and high molecular weight targets.
Overview
In tank or wet transfer the assembled cassette is completely submerged in transfer buffer, and current flows from the cathode plate through the gel and membrane to the anode. Because the buffer volume is large, heat is dissipated more effectively and higher molecular weight proteins transfer more completely than in semi-dry systems. Typical conditions are 100 V for 60–120 minutes at room temperature or 30–40 V overnight with cooling. Methanol at 10–20% improves binding to nitrocellulose but can cause gel shrinkage and reduce transfer of large proteins, so SDS is sometimes added to improve their mobility. Tanks accept mini, midi and large format gels, and multi-cassette units process several blots at once with a magnetic stir bar or built-in cooling coil to keep buffer temperature uniform.
How does it work?
Western blotting starts with separation of proteins by SDS-PAGE or a capillary system. In conventional blotting, the gel is placed against a nitrocellulose or PVDF membrane in a transfer stack and an electric field drives the negatively charged proteins out of the gel onto the membrane, where they bind by hydrophobic and electrostatic interaction. The membrane is then blocked with protein or detergent to saturate remaining binding sites, incubated with a primary antibody against the target, washed, incubated with an enzyme- or fluorophore-labelled secondary antibody that recognises the primary antibody, and washed again. Bound enzyme is detected by adding a chemiluminescent or colorimetric substrate, and the signal is imaged and quantified against a standard or a loading control. Automated capillary systems perform the equivalent steps in a capillary with a separation matrix and immobilised reagents.
What are the key features?
- Fully submerged cassette with plate electrodes on both sides
- Accepts mini, midi and large format gels
- Multi-cassette options for several blots per run
- Built-in cooling coil or stir bar for temperature uniformity
- High transfer efficiency for proteins above 100 kDa
- Colour-coded electrode module to prevent reversed polarity
What are the technical specifications?
A typical tank transfer blotting system configuration offers gel formats of Mini (8 x 10 cm), midi and large (16 x 20 cm), cassette capacity of 1–4 cassettes (model dependent), transfer time of approx. 60–120 min at 100 V, or overnight at 30–40 V, maximum voltage of up to 200 V, maximum current of up to 2 A (model dependent) and buffer volume of approx. 500–3,000 mL. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Tank Transfer Blotting System is used in high molecular weight protein blotting, large format preparative blot transfer, membrane protein immunodetection and multi-sample comparative blotting. Across the wider Western Blot Systems class, laboratories also deploy it for specific protein detection in cell lysates, recombinant protein expression monitoring and biopharmaceutical purity and identity testing.
Which standards and certifications apply?
Relevant standards and methods include USP <1057>, Ph. Eur. 2.2.31, IEC 61010-1, ISO 17025, 21 CFR Part 11 and ISO 9001. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Transfer efficiency depends on current, time, buffer composition and the amount of methanol or SDS, so conditions should be established for each target protein and recorded in the method. Air bubbles trapped in the stack cause localised transfer gaps, and membranes must be handled with gloves and kept wet once activated. Blocking agent choice affects background and antibody binding, and milk-based blockers can interfere with phospho-specific antibodies. Wash volumes and times must be consistent to keep background low. Chemiluminescent substrates fade quickly, so images should be captured within the recommended window, and quantitative comparisons should include a loading control on the same membrane. Store antibodies in aliquots at the recommended temperature and record lot numbers, because antibody performance varies between lots.
How do I select the right Tank Transfer Blotting System?
Select a tank transfer system when high molecular weight proteins, large format gels or maximum transfer efficiency are priorities. Specify gel formats, cassette capacity, voltage and current limits, buffer volume and whether active cooling is required for overnight runs.
How does it compare with other Western Blot Systems variants?
Choose first between conventional and automated blotting. Conventional tank or semi-dry transfer with manual antibody incubation costs less per sample and allows flexible antibody choices, but requires more hands-on time and gives semi-quantitative results. Automated capillary systems reduce run time to a few hours, use nanolitre sample volumes and produce quantitative peak areas, which suits regulated laboratories generating many comparable data sets. For conventional workflows, decide transfer format by gel size and protein molecular weight: tank transfer suits large gels and high molecular weight proteins, semi-dry transfer is faster and uses less buffer, and vacuum transfer is useful for thick gels. Check membrane and gel dimensions, electrode type, current and voltage range, cooling options and whether the system handles multiple gels at once.
Full specifications
| Gel formats | Mini (8 x 10 cm), midi and large (16 x 20 cm) |
|---|---|
| Cassette capacity | 1–4 cassettes (model dependent) |
| Transfer time | approx. 60–120 min at 100 V, or overnight at 30–40 V |
| Maximum voltage | up to 200 V |
| Maximum current | up to 2 A (model dependent) |
| Buffer volume | approx. 500–3,000 mL |
| Cooling | Internal coil for cold water or recirculation |
| Electrode material | Platinum wire or platinum-coated titanium plate |
| Membrane types | Nitrocellulose and PVDF |
| Dimensions (W x D x H) | approx. 200 x 200 x 200 mm |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- High molecular weight protein blotting
- Large format preparative blot transfer
- Membrane protein immunodetection
- Multi-sample comparative blotting
Key features
- Fully submerged cassette with plate electrodes on both sides
- Accepts mini, midi and large format gels
- Multi-cassette options for several blots per run
- Built-in cooling coil or stir bar for temperature uniformity
- High transfer efficiency for proteins above 100 kDa
- Colour-coded electrode module to prevent reversed polarity
Frequently asked questions about Tank Transfer Blotting System
Commonly 60–120 minutes at 100 V at room temperature, or overnight at 30–40 V with cooling. Higher molecular weight targets and thicker gels favour longer runs at lower voltage to limit heating and gel distortion.
Methanol improves protein binding to nitrocellulose and prevents gel swelling, but it also strips SDS from proteins and can reduce transfer of large proteins. Protocols often lower methanol to 10% or add 0.02–0.1% SDS for high molecular weight targets.
Yes. Multi-cassette tanks hold two to four cassettes in parallel electrodes, with the same current flowing through each. All cassettes should use identical gel thickness and buffer composition so that transfer conditions stay comparable.
An electric field drives negatively charged SDS-coated proteins out of the gel and onto a nitrocellulose or PVDF membrane placed against it. Proteins bind the membrane by hydrophobic and electrostatic interactions, after which antibodies detect the target.
Nitrocellulose binds proteins well and gives low background for most chemiluminescent detection. PVDF has higher binding capacity and better mechanical strength, which helps with repeated stripping and reprobing and with low-abundance or small proteins.
Use a pre-stained molecular weight ladder on the gel, and stain the membrane with Ponceau S or a reversible protein stain to confirm that proteins have moved. Staining the gel after transfer shows how much protein remains behind.
Related models