Semi-Dry Western Blot Transfer System
半干转印系统
- SKU WBS-0002
- Western Blot Systems
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IEC 61010-1 safety (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Gel capacity | 1–4 mini or midi gels |
|---|---|
| Transfer time | approx. 15–60 min |
| Maximum current | up to 400 mA (model dependent) |
| Maximum voltage | up to 30 V |
| Electrode area | approx. 150 x 150 mm |
| Buffer volume | approx. 20–60 mL per transfer |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <1057>, Ph. Eur. 2.2.31, IEC 61010-1
What is the Semi-Dry Western Blot Transfer System?
A semi-dry transfer system places the gel and membrane between flat plate electrodes with only a few buffer-soaked filter pads, completing transfer in 15 to 60 minutes with minimal buffer. It suits routine blotting of mini and midi gels.
What is the Semi-Dry Western Blot Transfer System?
A semi-dry transfer system places the gel and membrane between flat plate electrodes with only a few buffer-soaked filter pads, completing transfer in 15 to 60 minutes with minimal buffer. It suits routine blotting of mini and midi gels.
Overview
In semi-dry transfer the gel and membrane are sandwiched between buffer-saturated filter papers and placed directly between a flat anode and cathode plate. Because there is little buffer volume, current densities are high, typically 1–3 mA per square centimetre, and transfer completes in 15–60 minutes. The method uses much less buffer than tank transfer and needs no cooling system for standard runs. Transfer efficiency for proteins above about 100 kDa is lower than with tank systems and can be improved with extended times, modified buffer composition or lower methanol content. Electrodes require regular cleaning to remove deposited salts and proteins, and filter papers must be saturated evenly to avoid dry spots that cause local heating and discontinuous transfer. The format is available for mini and midi gels and is easy to scale to several gels at once.
How does it work?
Western blotting starts with separation of proteins by SDS-PAGE or a capillary system. In conventional blotting, the gel is placed against a nitrocellulose or PVDF membrane in a transfer stack and an electric field drives the negatively charged proteins out of the gel onto the membrane, where they bind by hydrophobic and electrostatic interaction. The membrane is then blocked with protein or detergent to saturate remaining binding sites, incubated with a primary antibody against the target, washed, incubated with an enzyme- or fluorophore-labelled secondary antibody that recognises the primary antibody, and washed again. Bound enzyme is detected by adding a chemiluminescent or colorimetric substrate, and the signal is imaged and quantified against a standard or a loading control. Automated capillary systems perform the equivalent steps in a capillary with a separation matrix and immobilised reagents.
What are the key features?
- Flat plate electrodes with 15–60 minute transfer times
- Buffer consumption of only a few millilitres per transfer
- Accommodates one to four mini or midi gels per run
- Adjustable current or voltage with programmable time
- Stainless steel or platinum-coated plate electrodes
- No cooling system required for standard protocols
What are the technical specifications?
A typical semi-dry western blot transfer system configuration offers gel capacity of 1–4 mini or midi gels, transfer time of approx. 15–60 min, maximum current of up to 400 mA (model dependent), maximum voltage of up to 30 V, electrode area of approx. 150 x 150 mm and buffer volume of approx. 20–60 mL per transfer. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Semi-Dry Western Blot Transfer System is used in routine immunoblotting of mini gels, multiple membrane and antibody screening, phosphoprotein detection and teaching laboratory blotting exercises. Across the wider Western Blot Systems class, laboratories also deploy it for specific protein detection in cell lysates, recombinant protein expression monitoring and biopharmaceutical purity and identity testing.
Which standards and certifications apply?
Relevant standards and methods include USP <1057>, Ph. Eur. 2.2.31, IEC 61010-1, ISO 17025, 21 CFR Part 11 and ISO 9001. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Transfer efficiency depends on current, time, buffer composition and the amount of methanol or SDS, so conditions should be established for each target protein and recorded in the method. Air bubbles trapped in the stack cause localised transfer gaps, and membranes must be handled with gloves and kept wet once activated. Blocking agent choice affects background and antibody binding, and milk-based blockers can interfere with phospho-specific antibodies. Wash volumes and times must be consistent to keep background low. Chemiluminescent substrates fade quickly, so images should be captured within the recommended window, and quantitative comparisons should include a loading control on the same membrane. Store antibodies in aliquots at the recommended temperature and record lot numbers, because antibody performance varies between lots.
How do I select the right Semi-Dry Western Blot Transfer System?
Select a semi-dry system for routine blotting of mini and midi gels where speed and low buffer consumption matter more than maximum transfer efficiency for very large proteins. Specify gel capacity, electrode area, current and voltage limits and programmability.
How does it compare with other Western Blot Systems variants?
Choose first between conventional and automated blotting. Conventional tank or semi-dry transfer with manual antibody incubation costs less per sample and allows flexible antibody choices, but requires more hands-on time and gives semi-quantitative results. Automated capillary systems reduce run time to a few hours, use nanolitre sample volumes and produce quantitative peak areas, which suits regulated laboratories generating many comparable data sets. For conventional workflows, decide transfer format by gel size and protein molecular weight: tank transfer suits large gels and high molecular weight proteins, semi-dry transfer is faster and uses less buffer, and vacuum transfer is useful for thick gels. Check membrane and gel dimensions, electrode type, current and voltage range, cooling options and whether the system handles multiple gels at once.
Full specifications
| Gel capacity | 1–4 mini or midi gels |
|---|---|
| Transfer time | approx. 15–60 min |
| Maximum current | up to 400 mA (model dependent) |
| Maximum voltage | up to 30 V |
| Electrode area | approx. 150 x 150 mm |
| Buffer volume | approx. 20–60 mL per transfer |
| Cooling | Passive, ambient air |
| Electrode material | Stainless steel or platinum-coated titanium |
| Membrane types | Nitrocellulose and PVDF |
| Dimensions (W x D x H) | approx. 250 x 200 x 100 mm |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Routine immunoblotting of mini gels
- Multiple membrane and antibody screening
- Phosphoprotein detection
- Teaching laboratory blotting exercises
Key features
- Flat plate electrodes with 15–60 minute transfer times
- Buffer consumption of only a few millilitres per transfer
- Accommodates one to four mini or midi gels per run
- Adjustable current or voltage with programmable time
- Stainless steel or platinum-coated plate electrodes
- No cooling system required for standard protocols
Frequently asked questions about Semi-Dry Western Blot Transfer System
Most protocols run for 15–60 minutes at 1–3 mA per square centimetre. Transfer time increases for proteins above 100 kDa and can be shortened by raising current, but excessive current causes heating and drying of the stack.
It is less efficient than tank transfer for proteins above about 100 kDa. Longer transfer times, lower methanol or added SDS in the buffer, and PVDF membranes with 0.2 µm pores improve recovery of large proteins.
Dry spots occur when filter papers or membranes are not fully saturated or when current is too high, causing local heating and evaporation. Saturating all layers evenly and using the recommended current density prevents discontinuous transfer.
An electric field drives negatively charged SDS-coated proteins out of the gel and onto a nitrocellulose or PVDF membrane placed against it. Proteins bind the membrane by hydrophobic and electrostatic interactions, after which antibodies detect the target.
Nitrocellulose binds proteins well and gives low background for most chemiluminescent detection. PVDF has higher binding capacity and better mechanical strength, which helps with repeated stripping and reprobing and with low-abundance or small proteins.
Use a pre-stained molecular weight ladder on the gel, and stain the membrane with Ponceau S or a reversible protein stain to confirm that proteins have moved. Staining the gel after transfer shows how much protein remains behind.