Protein Imaging

蛋白质成像系统

PRI · Protein Analysis Equipment · 5 models

By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <1057>, Ph. Eur. 2.2.31, IEC 61010-1

Standards referenced

  • USP <1057>
  • Ph. Eur. 2.2.31
  • IEC 61010-1
  • ISO 17025
  • 21 CFR Part 11
  • ISO 9001

What are Protein Imaging?

Protein imaging systems detect and quantify chemiluminescent, fluorescent or colorimetric signals from western blots and stained protein gels, producing images for purity calculation and expression comparison. They are used in protein research, biopharmaceutical quality control and clinical protein laboratories.

5 models of Protein Imaging

The 5 models below are current configurations; specifications are confirmed on quotation.

Automated Chemiluminescence Imaging System

自动化学发光成像系统

  • PRI-0001
  • Protein Imaging
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
Sensor:
Cooled CCD or CMOS, approx. 4–16 MP
Cooling temperature:
approx. −25 to −60 °C
Dynamic range:
approx. 3–4 orders of magnitude
Detection limit:
low picogram range of protein per band
Exposure time:
0.1 s to 60 min, automatic or manual
Imaging area:
approx. 150 x 150 mm

An automated chemiluminescence imaging system uses a cooled CCD or CMOS sensor to capture the light emitted by enzyme-labelled blots without any excitation source, giving high sensitivity and low background for routine western blot quantification.

Request a quote
View details

Near-Infrared Fluorescence Imaging System

近红外荧光成像系统

  • PRI-0002
  • Protein Imaging
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
Excitation wavelengths:
approx. 685 and 785 nm
Emission filters:
approx. 720 and 820 nm
Dynamic range:
approx. 3–4 orders of magnitude
Detection limit:
low femtogram to picogram per band (antibody dependent)
Scan time:
approx. 2–10 min per membrane
Imaging area:
approx. 100 x 150 mm

A near-infrared fluorescence imaging system excites antibodies labelled with 700 and 800 nm fluorophores and detects the emission with matched filters, giving low background multiplexing and a wide linear range for quantitative western blotting.

Request a quote
View details

Gel Documentation Imaging System

凝胶成像系统

  • PRI-0003
  • Protein Imaging
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
Illumination:
White transillumination, optional 254/302/365 nm UV
Camera resolution:
approx. 5–20 MP colour
Spatial resolution:
approx. 0.05–0.2 mm per pixel
Dynamic range:
approx. 2–3 orders of magnitude
Imaging area:
approx. 200 x 250 mm
Exposure control:
Automatic and manual

A gel documentation imaging system uses uniform white or ultraviolet illumination and a colour camera to record stained protein gels, providing digital images for purity assessment and laboratory records at low cost.

Request a quote
View details

Laser Scanning Imaging System

激光扫描成像系统

  • PRI-0004
  • Protein Imaging
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
Resolution:
10–200 µm selectable
Dynamic range:
approx. 4–5 orders of magnitude
Excitation wavelengths:
488, 532, 635 and 685 nm options
Detection:
Photomultiplier tube with emission filters
Scan area:
approx. 250 x 250 mm
Scan time:
approx. 1–30 min depending on resolution

A laser scanning imaging system moves a focused beam point by point across a blot, gel or storage phosphor screen and records the signal with a photomultiplier, giving high spatial resolution and a very wide linear dynamic range for quantitative densitometry.

Request a quote
View details

Multispectral Fluorescence Imaging System

多光谱荧光成像系统

  • PRI-0005
  • Protein Imaging
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
Spectral channels:
8–32 narrow bands or continuous spectral scan
Wavelength range:
approx. 400–900 nm
Multiplex capacity:
5–7 targets per sample (dye dependent)
Excitation sources:
LED or laser lines, 4–8 selectable
Detector:
Cooled CCD or sCMOS
Unmixing:
Linear unmixing from single-colour reference spectra

A multispectral fluorescence imaging system captures the emission spectrum at each pixel and separates overlapping signals computationally, allowing five or more targets to be resolved on one blot or tissue section with reduced autofluorescence interference.

Request a quote
View details

Compare Protein Imaging models

ModelDynamic rangeDetection limitImaging areaResolutionIllumination
Automated Chemiluminescence Imaging SystemPRI-0001approx. 3–4 orders of magnitudelow picogram range of protein per bandapprox. 150 x 150 mmapprox. 0.02–0.1 mm per pixelWhite epi and transillumination for colour markers
Near-Infrared Fluorescence Imaging SystemPRI-0002approx. 3–4 orders of magnitudelow femtogram to picogram per band (antibody dependent)approx. 100 x 150 mmapprox. 0.02–0.2 mm per pixel—
Gel Documentation Imaging SystemPRI-0003approx. 2–3 orders of magnitude—approx. 200 x 250 mm—White transillumination, optional 254/302/365 nm UV
Laser Scanning Imaging SystemPRI-0004approx. 4–5 orders of magnitudelow femtomole to picomole per band (label dependent)—10–200 µm selectable—
Multispectral Fluorescence Imaging SystemPRI-0005——approx. 100 x 150 mmapprox. 0.02–0.1 mm per pixel—

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do Protein Imaging work?

Imaging systems convert a signal on a membrane or gel surface into a calibrated digital image. In chemiluminescence imaging, no excitation light is needed: an enzyme such as horseradish peroxidase converts a substrate into an excited product that emits light, and a cooled CCD or CMOS sensor integrates that faint emission over minutes. Fluorescence imaging instead excites fluorophores with LEDs or lasers and collects emitted light through bandpass filters, which allows multiplexing with differently labelled antibodies. Colorimetric systems use white or coloured illumination and measure transmitted or reflected light to quantify stained bands such as Coomassie blue. Laser scanning instruments move a focused beam across the surface and record point by point, which gives high spatial resolution and a wide linear dynamic range. In all cases the software subtracts background, converts pixel intensities to optical density, and compares bands with a standard or loading control.

Which Protein Imaging variants are available?

  • Automated Chemiluminescence Imaging System — An automated chemiluminescence imaging system uses a cooled CCD or CMOS sensor to capture the light emitted by enzyme-labelled blots without any excitation source, giving high sensitivity and low background for routine western blot quantification.
  • Near-Infrared Fluorescence Imaging System — A near-infrared fluorescence imaging system excites antibodies labelled with 700 and 800 nm fluorophores and detects the emission with matched filters, giving low background multiplexing and a wide linear range for quantitative western blotting.
  • Gel Documentation Imaging System — A gel documentation imaging system uses uniform white or ultraviolet illumination and a colour camera to record stained protein gels, providing digital images for purity assessment and laboratory records at low cost.
  • Laser Scanning Imaging System — A laser scanning imaging system moves a focused beam point by point across a blot, gel or storage phosphor screen and records the signal with a photomultiplier, giving high spatial resolution and a very wide linear dynamic range for quantitative densitometry.
  • Multispectral Fluorescence Imaging System — A multispectral fluorescence imaging system captures the emission spectrum at each pixel and separates overlapping signals computationally, allowing five or more targets to be resolved on one blot or tissue section with reduced autofluorescence interference.

How do I choose the right variant?

Choose the detector that matches your detection chemistry. Chemiluminescence needs a cooled sensor with low dark current and long integration times, and absolute sensitivity matters more than resolution. Fluorescence needs matched excitation sources and emission filters, and filter selection should cover the dyes you actually use, including near-infrared pairs for low-background multiplexing. Colorimetric and densitometry work needs uniform illumination and colour calibration to make Coomassie or silver staining quantitative. Laser scanning suits applications where a wide linear dynamic range and high resolution are essential, such as purity determination with small impurity peaks. Check the camera or scanner resolution in millimetres per pixel, dynamic range in orders of magnitude, cooling temperature, imaging area, light source lifetime and whether the software supports background subtraction, saturation warnings, lane profiling and export of numerical data.

Where are Protein Imaging used?

Protein Imaging are specified in western blot band quantification, protein purity assessment from stained gels, multiplexed fluorescence immunodetection, documentation of protein gels for reports and audits and phosphoprotein and signalling analysis.

Which standards and certifications apply?

Work with Protein Imaging is commonly governed by USP <1057>, Ph. Eur. 2.2.31, IEC 61010-1, ISO 17025, 21 CFR Part 11 and ISO 9001. Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

Keep the imaging area clean and free of dust, because particles scatter light and appear as false bands. Avoid saturating the sensor, since saturated pixels cannot be used for quantification; most software flags them, and exposure series should be used to confirm the signal is in the linear range. Chemiluminescent substrates decay within minutes to an hour, so imaging should follow the supplier's timing recommendation and be consistent between samples. Fluorescent blots fade with repeated exposure, so images should be captured once where possible. Calibrate the instrument periodically with a step tablet or fluorescence standard and record the settings used, so that images from different sessions remain comparable. Archive raw files, not only processed figures, because quantitative results may need re-analysis.

Frequently asked questions about Protein Imaging

Chemiluminescence needs no excitation light, so background is low and sensitivity high, but only one target can be detected at a time. Fluorescence excites labelled probes with LEDs or lasers, enabling multiplexing with different dyes, at the cost of higher autofluorescence and more careful filter selection.