Gel Documentation Imaging System — product photo

Gel Documentation Imaging System

凝胶成像系统

  • SKU PRI-0003
  • Protein Imaging
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
IlluminationWhite transillumination, optional 254/302/365 nm UV
Camera resolutionapprox. 5–20 MP colour
Spatial resolutionapprox. 0.05–0.2 mm per pixel
Dynamic rangeapprox. 2–3 orders of magnitude
Imaging areaapprox. 200 x 250 mm
Exposure controlAutomatic and manual
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <1057>, Ph. Eur. 2.2.31, IEC 61010-1

What is the Gel Documentation Imaging System?

A gel documentation imaging system uses uniform white or ultraviolet illumination and a colour camera to record stained protein gels, providing digital images for purity assessment and laboratory records at low cost.

What is the Gel Documentation Imaging System?

A gel documentation imaging system uses uniform white or ultraviolet illumination and a colour camera to record stained protein gels, providing digital images for purity assessment and laboratory records at low cost.

Overview

The system places the gel on a transilluminator or white light pad inside a dark hood and captures an image with a fixed-focus or zoom camera. Coomassie-stained gels are imaged in white transmitted light, silver-stained gels usually on a white or clear background, and fluorescent stains such as SYPRO with appropriate excitation. Software provides automatic exposure, colour or grey-scale capture, background flattening and lane profiling, and reports band intensity as a percentage of total lane signal for purity estimation. Resolution is usually lower than in scientific-grade imaging systems, typically 0.05–0.2 mm per pixel, which is adequate for bands of moderate intensity but not for detecting faint impurity peaks. Ultraviolet models require interlocked safety shielding and should be used with UV-blocking face protection.

How does it work?

Imaging systems convert a signal on a membrane or gel surface into a calibrated digital image. In chemiluminescence imaging, no excitation light is needed: an enzyme such as horseradish peroxidase converts a substrate into an excited product that emits light, and a cooled CCD or CMOS sensor integrates that faint emission over minutes. Fluorescence imaging instead excites fluorophores with LEDs or lasers and collects emitted light through bandpass filters, which allows multiplexing with differently labelled antibodies. Colorimetric systems use white or coloured illumination and measure transmitted or reflected light to quantify stained bands such as Coomassie blue. Laser scanning instruments move a focused beam across the surface and record point by point, which gives high spatial resolution and a wide linear dynamic range. In all cases the software subtracts background, converts pixel intensities to optical density, and compares bands with a standard or loading control.

What are the key features?

  • White light transilluminator and ultraviolet option with interlock
  • Colour or grey-scale camera with automatic exposure
  • Software background flattening and lane profiling
  • Purity estimation as percentage of total lane intensity
  • Fixed hood with dark background for consistent lighting
  • Digital image archive with metadata recording

What are the technical specifications?

A typical gel documentation imaging system configuration offers illumination of White transillumination, optional 254/302/365 nm UV, camera resolution of approx. 5–20 MP colour, spatial resolution of approx. 0.05–0.2 mm per pixel, dynamic range of approx. 2–3 orders of magnitude, imaging area of approx. 200 x 250 mm and exposure control of Automatic and manual. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Gel Documentation Imaging System is used in purity assessment of stained gels, routine documentation of electrophoresis results, teaching laboratory gel imaging and comparison of purification fractions. Across the wider Protein Imaging class, laboratories also deploy it for western blot band quantification, protein purity assessment from stained gels and multiplexed fluorescence immunodetection.

Which standards and certifications apply?

Relevant standards and methods include USP <1057>, Ph. Eur. 2.2.31, IEC 61010-1, ISO 17025, 21 CFR Part 11 and ISO 9001. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Keep the imaging area clean and free of dust, because particles scatter light and appear as false bands. Avoid saturating the sensor, since saturated pixels cannot be used for quantification; most software flags them, and exposure series should be used to confirm the signal is in the linear range. Chemiluminescent substrates decay within minutes to an hour, so imaging should follow the supplier's timing recommendation and be consistent between samples. Fluorescent blots fade with repeated exposure, so images should be captured once where possible. Calibrate the instrument periodically with a step tablet or fluorescence standard and record the settings used, so that images from different sessions remain comparable. Archive raw files, not only processed figures, because quantitative results may need re-analysis.

How do I select the right Gel Documentation Imaging System?

Select a gel documentation system for routine, low-cost documentation of stained gels where approximate quantification is acceptable. Specify illumination type, camera resolution, imaging area, stain compatibility, UV safety features and the analysis functions of the software.

How does it compare with other Protein Imaging variants?

Choose the detector that matches your detection chemistry. Chemiluminescence needs a cooled sensor with low dark current and long integration times, and absolute sensitivity matters more than resolution. Fluorescence needs matched excitation sources and emission filters, and filter selection should cover the dyes you actually use, including near-infrared pairs for low-background multiplexing. Colorimetric and densitometry work needs uniform illumination and colour calibration to make Coomassie or silver staining quantitative. Laser scanning suits applications where a wide linear dynamic range and high resolution are essential, such as purity determination with small impurity peaks. Check the camera or scanner resolution in millimetres per pixel, dynamic range in orders of magnitude, cooling temperature, imaging area, light source lifetime and whether the software supports background subtraction, saturation warnings, lane profiling and export of numerical data.

Full specifications

Full specifications
IlluminationWhite transillumination, optional 254/302/365 nm UV
Camera resolutionapprox. 5–20 MP colour
Spatial resolutionapprox. 0.05–0.2 mm per pixel
Dynamic rangeapprox. 2–3 orders of magnitude
Imaging areaapprox. 200 x 250 mm
Exposure controlAutomatic and manual
Stain compatibilityCoomassie, silver, zinc and fluorescent stains
SoftwareLane profile, purity percentage, image export
UV safetyInterlocked hood for UV models
Dimensions (W x D x H)approx. 400 x 400 x 600 mm

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Purity assessment of stained gels
  • Routine documentation of electrophoresis results
  • Teaching laboratory gel imaging
  • Comparison of purification fractions

Key features

  • White light transilluminator and ultraviolet option with interlock
  • Colour or grey-scale camera with automatic exposure
  • Software background flattening and lane profiling
  • Purity estimation as percentage of total lane intensity
  • Fixed hood with dark background for consistent lighting
  • Digital image archive with metadata recording

Frequently asked questions about Gel Documentation Imaging System

It can report approximate purity percentages where the bands are well separated and the signal is in the linear range, but its narrower dynamic range limits detection of faint impurity bands. Regulated purity results are usually confirmed by capillary electrophoresis or chromatography.

Related models

All Protein Imaging

Request a quotation for the Gel Documentation Imaging System