Cell Analysis

细胞分析仪器

CEA · Life Science Equipment · 5 models

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-101, IEC 61326-2-6

Standards referenced

  • IEC 61010-1
  • IEC 61010-2-101
  • IEC 61326-2-6
  • IEC 60825-1
  • ISO 13322-1
  • ISO 13319

What are Cell Analysis?

Cell analysis instruments count cells, measure viability and size, and characterize cell populations using image analysis, electrical impedance or laser-based detection. They are used in cell culture, cell therapy, biopharmaceutical bioprocessing, immunology and cancer research to standardize seeding density and monitor culture health.

5 models of Cell Analysis

The 5 models below are current configurations; specifications are confirmed on quotation.

Image-Based Automated Cell Counter

图像式自动细胞计数仪

  • CEA-0001
  • Cell Analysis
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Counting range:
1 × 10⁴–1 × 10⁷ cells/mL
Cell size range:
5–60 μm
Sample volume:
10 μL
Time per count:
10–30 s
Viability method:
Trypan blue exclusion
Camera:
5 MP CMOS

An image-based automated cell counter photographs a stained cell suspension in a disposable slide and uses software to count cells and classify viability by trypan blue exclusion. It suits routine culture laboratories needing results in under a minute from 10 μL of sample.

Request a quote
View details

Fluorescence Cell Counter and Viability Analyzer

荧光细胞计数与活率分析仪

  • CEA-0002
  • Cell Analysis
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Counting range:
5 × 10⁴–3 × 10⁷ cells/mL
Fluorescence channels:
2 (green, red)
Excitation sources:
Blue and green LEDs
Sample volume:
20 μL
Analysis time:
approx. 30 s
Viability stains:
AO/PI; trypan blue in brightfield

A fluorescence cell counter and viability analyzer uses acridine orange and propidium iodide staining with fluorescence imaging to count nucleated cells and determine viability. It is the better choice for primary cells, PBMCs and debris-rich samples where brightfield trypan blue methods are unreliable.

Request a quote
View details

Impedance-Based Cell Counter

阻抗式细胞计数仪

  • CEA-0003
  • Cell Analysis
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • ISO 13319 method support (to be confirmed)
Aperture diameter:
50, 100, 150, 200 μm options
Particle size range:
approx. 2–60 μm
Counting range:
up to 1 × 10⁵ particles/mL after dilution
Sample volume counted:
50–500 μL
Analysis time:
10–20 s
Count precision (CV):
below 3 % (typical)

An impedance-based cell counter applies the Coulter principle, sensing the electrical resistance change as each cell passes through a micro-aperture in electrolyte. It gives precise concentration and volume-based size distribution in seconds, and it suits large sample counts, yeast and mammalian cell lines.

Request a quote
View details

Benchtop Flow Cytometer

台式流式细胞仪

  • CEA-0004
  • Cell Analysis
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 60825-1 laser product classification (to be confirmed)
Lasers:
488 nm, optional 405 and 640 nm
Fluorescence channels:
2–8 colors
Scatter detection:
FSC, SSC
Acquisition rate:
up to 10,000–35,000 events/s
Sample flow rate:
10–120 μL/min
Fluorescence sensitivity:
FITC below 500 MESF (typical)

A benchtop flow cytometer analyzes individual cells as they pass lasers, measuring scatter and multiple fluorescence signals per cell. It is the right tool for immunophenotyping, apoptosis and cell cycle analysis in research laboratories needing two to eight colors without a large core-facility instrument.

Request a quote
View details

Bioprocess Cell Viability Analyzer

生物工艺细胞活率分析仪

  • CEA-0005
  • Cell Analysis
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • 21 CFR Part 11 software capability (to be confirmed)
Viable cell density range:
5 × 10⁴–2 × 10⁸ cells/mL
Automated dilution:
1:1 to 1:100
Sample volume:
100–500 μL
Throughput:
up to 40 samples per rack
Time per sample:
approx. 1–2 min
Viability method:
Trypan blue exclusion

A bioprocess cell viability analyzer automates sampling, dilution, trypan blue staining and image analysis for bioreactor cultures, reporting viable cell density and viability with minimal handling. It is intended for CHO, hybridoma and insect cell process development and manufacturing support laboratories.

Request a quote
View details

Compare Cell Analysis models

ModelCounting rangeCell size rangeSample volumeViability methodData export
Image-Based Automated Cell CounterCEA-00011 × 10⁴–1 × 10⁷ cells/mL5–60 μm10 μLTrypan blue exclusionUSB, Ethernet, CSV/PDF
Fluorescence Cell Counter and Viability AnalyzerCEA-00025 × 10⁴–3 × 10⁷ cells/mL4–60 μm20 μL—USB, LIMS-ready CSV
Impedance-Based Cell CounterCEA-0003up to 1 × 10⁵ particles/mL after dilution————
Benchtop Flow CytometerCEA-0004—————
Bioprocess Cell Viability AnalyzerCEA-0005——100–500 μLTrypan blue exclusion—

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do Cell Analysis work?

Cell analysis instruments use three main detection principles. Image-based counters photograph cells in a counting chamber, then software segments cells and classifies them as live or dead by dye exclusion, for example trypan blue, or by fluorescence with acridine orange and propidium iodide. Impedance counters, based on the Coulter principle, draw cells through a micro-aperture and record the electrical resistance pulse, whose amplitude is proportional to cell volume. Flow cytometers hydrodynamically focus cells into a single file past one or more lasers, detect forward and side scatter plus fluorescence through dichroic mirrors and bandpass filters, and convert photons to digital events with photomultiplier tubes or avalanche photodiodes. Software then gates populations and reports concentration, viability, size distribution and marker expression.

Which Cell Analysis variants are available?

  • Image-Based Automated Cell Counter — An image-based automated cell counter photographs a stained cell suspension in a disposable slide and uses software to count cells and classify viability by trypan blue exclusion.
  • Fluorescence Cell Counter and Viability Analyzer — A fluorescence cell counter and viability analyzer uses acridine orange and propidium iodide staining with fluorescence imaging to count nucleated cells and determine viability.
  • Impedance-Based Cell Counter — An impedance-based cell counter applies the Coulter principle, sensing the electrical resistance change as each cell passes through a micro-aperture in electrolyte.
  • Benchtop Flow Cytometer — A benchtop flow cytometer analyzes individual cells as they pass lasers, measuring scatter and multiple fluorescence signals per cell.
  • Bioprocess Cell Viability Analyzer — A bioprocess cell viability analyzer automates sampling, dilution, trypan blue staining and image analysis for bioreactor cultures, reporting viable cell density and viability with minimal handling.

How do I choose the right variant?

Start with the question you need answered. For concentration and viability only, an image-based counter or impedance counter is fast and inexpensive. For immunophenotyping, cell cycle or apoptosis, you need a flow cytometer with the right lasers and detector channels for your fluorochromes. Consider sample characteristics: clumping, debris, primary cells or platelets affect image segmentation, and small particles require an impedance aperture of suitable diameter. Check the counting range in cells per mL and the sample volume required, especially for scarce samples. Review consumable costs, since slides or cartridges often dominate running costs. Confirm software features for data export, user control and audit trail, and whether the instrument supports the sample types used in cell therapy or bioprocess workflows.

Where are Cell Analysis used?

Cell Analysis are specified in cell culture seeding and passaging, cell therapy product characterization, bioprocess viability monitoring, immunophenotyping and apoptosis studies and blood and immune cell research.

Which standards and certifications apply?

Work with Cell Analysis is commonly governed by IEC 61010-1, IEC 61010-2-101, IEC 61326-2-6, IEC 60825-1, ISO 13322-1 and ISO 13319. Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

Cell analyzers need regular optical and fluidic verification. Image counters should be checked with count-bead or latex standards, and impedance counters with calibration particles at the aperture size. Flow cytometers require daily quality control with fluorescent beads, fluidic cleaning after each session and periodic laser alignment checks. Install flow cytometers away from vibration and heat, with stable power and, if needed, a waste decontamination procedure for biohazardous samples. Use consumables from the validated lot, handle cell suspensions gently to avoid clumping, and standardize dye concentrations and incubation times. Regulated laboratories should verify software access control and audit trail.

Frequently asked questions about Cell Analysis

A cell analyzer measures how many cells are in a sample, what fraction are alive, their size distribution and, with fluorescence, which markers they express. Laboratories use it to standardize seeding density, monitor culture health, check cell therapy products and characterize immune populations.

Need help specifying Cell Analysis?