Impedance-Based Cell Counter
阻抗式细胞计数仪
- SKU CEA-0003
- Cell Analysis
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- ISO 13319 method support (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Aperture diameter | 50, 100, 150, 200 μm options |
|---|---|
| Particle size range | approx. 2–60 μm |
| Counting range | up to 1 × 10⁵ particles/mL after dilution |
| Sample volume counted | 50–500 μL |
| Analysis time | 10–20 s |
| Count precision (CV) | below 3 % (typical) |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-101, IEC 61326-2-6
What is the Impedance-Based Cell Counter?
An impedance-based cell counter applies the Coulter principle, sensing the electrical resistance change as each cell passes through a micro-aperture in electrolyte. It gives precise concentration and volume-based size distribution in seconds, and it suits large sample counts, yeast and mammalian cell lines.
What is the Impedance-Based Cell Counter?
An impedance-based cell counter applies the Coulter principle, sensing the electrical resistance change as each cell passes through a micro-aperture in electrolyte. It gives precise concentration and volume-based size distribution in seconds, and it suits large sample counts, yeast and mammalian cell lines.
Overview
In an impedance counter, particles suspended in electrolyte are drawn through an aperture, typically 50 to 200 μm in diameter, between two electrodes. Each particle displaces electrolyte and produces a voltage pulse proportional to its volume. Pulse counting yields concentration, and pulse height analysis gives a size distribution from roughly 2 to 60 μm, depending on aperture. Because no dyes or optics are involved, results are independent of color and optical properties. Viability is not directly measured unless combined with dead-cell size gating or a parallel method. Apertures can clog with clumps or debris and need to be unblocked or replaced. Samples are diluted in isotonic electrolyte, typically 1:100 to 1:1,000, and accuracy relies on consistent dilution.
How does it work?
Cell analysis instruments use three main detection principles. Image-based counters photograph cells in a counting chamber, then software segments cells and classifies them as live or dead by dye exclusion, for example trypan blue, or by fluorescence with acridine orange and propidium iodide. Impedance counters, based on the Coulter principle, draw cells through a micro-aperture and record the electrical resistance pulse, whose amplitude is proportional to cell volume. Flow cytometers hydrodynamically focus cells into a single file past one or more lasers, detect forward and side scatter plus fluorescence through dichroic mirrors and bandpass filters, and convert photons to digital events with photomultiplier tubes or avalanche photodiodes. Software then gates populations and reports concentration, viability, size distribution and marker expression.
What are the key features?
- Coulter-principle sensing gives volume-based size distribution with each count.
- Interchangeable apertures from 50 to 200 μm cover bacteria to large cells.
- Results are independent of staining and optical properties.
- Count times of a few seconds per sample support high sample numbers.
- Automatic aperture unblocking and cleaning cycle.
- Histogram display with adjustable lower and upper size gates.
What are the technical specifications?
A typical impedance-based cell counter configuration offers aperture diameter of 50, 100, 150, 200 μm options, particle size range of approx. 2–60 μm, counting range of up to 1 × 10⁵ particles/mL after dilution, sample volume counted of 50–500 μL, analysis time of 10–20 s and count precision (CV) of below 3 % (typical). Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Impedance-Based Cell Counter is used in yeast and fermentation monitoring, mammalian cell line counting, cell size and volume distribution studies and microalgae and particle counting. Across the wider Cell Analysis class, laboratories also deploy it for cell culture seeding and passaging, cell therapy product characterization and bioprocess viability monitoring.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-101, IEC 61326-2-6, IEC 60825-1, ISO 13322-1 and ISO 13319. Certification candidates for this model are CE, ISO 9001 manufacturing and ISO 13319 method support; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Cell analyzers need regular optical and fluidic verification. Image counters should be checked with count-bead or latex standards, and impedance counters with calibration particles at the aperture size. Flow cytometers require daily quality control with fluorescent beads, fluidic cleaning after each session and periodic laser alignment checks. Install flow cytometers away from vibration and heat, with stable power and, if needed, a waste decontamination procedure for biohazardous samples. Use consumables from the validated lot, handle cell suspensions gently to avoid clumping, and standardize dye concentrations and incubation times. Regulated laboratories should verify software access control and audit trail.
How do I select the right Impedance-Based Cell Counter?
Choose an impedance counter for high sample counts, yeast and cell size distribution work, or where dyes must be avoided. Specify aperture sizes, size range, dilution method and need for viability reporting. For viability, primary cells or morphology review, image-based counters are the better fit.
How does it compare with other Cell Analysis variants?
Start with the question you need answered. For concentration and viability only, an image-based counter or impedance counter is fast and inexpensive. For immunophenotyping, cell cycle or apoptosis, you need a flow cytometer with the right lasers and detector channels for your fluorochromes. Consider sample characteristics: clumping, debris, primary cells or platelets affect image segmentation, and small particles require an impedance aperture of suitable diameter. Check the counting range in cells per mL and the sample volume required, especially for scarce samples. Review consumable costs, since slides or cartridges often dominate running costs. Confirm software features for data export, user control and audit trail, and whether the instrument supports the sample types used in cell therapy or bioprocess workflows.
Full specifications
| Aperture diameter | 50, 100, 150, 200 μm options |
|---|---|
| Particle size range | approx. 2–60 μm |
| Counting range | up to 1 × 10⁵ particles/mL after dilution |
| Sample volume counted | 50–500 μL |
| Analysis time | 10–20 s |
| Count precision (CV) | below 3 % (typical) |
| Size resolution | 256 channels |
| Electrolyte | Isotonic saline or PBS |
| Data output | Histogram, CSV, printer |
| Power supply | 100–240 V, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Yeast and fermentation monitoring
- Mammalian cell line counting
- Cell size and volume distribution studies
- Microalgae and particle counting
Key features
- Coulter-principle sensing gives volume-based size distribution with each count.
- Interchangeable apertures from 50 to 200 μm cover bacteria to large cells.
- Results are independent of staining and optical properties.
- Count times of a few seconds per sample support high sample numbers.
- Automatic aperture unblocking and cleaning cycle.
- Histogram display with adjustable lower and upper size gates.
Frequently asked questions about Impedance-Based Cell Counter
The Coulter principle states that a particle passing through an aperture in a conductive liquid causes a brief increase in electrical resistance proportional to the particle volume. Counting these pulses gives concentration, and measuring their heights gives a volume-based size distribution.
Not directly, because it does not use dyes. Some models infer dead cells from size shifts, for example shrunken or swollen cells, but this is indicative. Use a dye-based method in parallel when viability is a release criterion.
Filter or gently dissociate clumpy samples, use the aperture diameter at least ten times larger than the largest expected particle, and run cleaning cycles with the manufacturer solution. Replace the aperture if repeated blockage or pulse noise persists.
A cell analyzer measures how many cells are in a sample, what fraction are alive, their size distribution and, with fluorescence, which markers they express. Laboratories use it to standardize seeding density, monitor culture health, check cell therapy products and characterize immune populations.
Automated counters typically deliver lower operator variability, with coefficients of variation of about 5 to 10 percent versus 15 to 25 percent for manual counting, but accuracy depends on focus, cell morphology and dye handling. Comparing results with a reference method during installation is good practice.
Trypan blue is excluded by live cells and stains dead cells blue, suitable for brightfield imaging. AO/PI uses fluorescence: acridine orange labels all nucleated cells and propidium iodide labels dead cells. AO/PI works better for samples with debris or red blood cells and in low-concentration samples.