Bioprocess Cell Viability Analyzer

生物工艺细胞活率分析仪

  • SKU CEA-0005
  • Cell Analysis
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • 21 CFR Part 11 software capability (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Viable cell density range5 × 10⁴–2 × 10⁸ cells/mL
Automated dilution1:1 to 1:100
Sample volume100–500 μL
Throughputup to 40 samples per rack
Time per sampleapprox. 1–2 min
Viability methodTrypan blue exclusion
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-101, IEC 61326-2-6

What is the Bioprocess Cell Viability Analyzer?

A bioprocess cell viability analyzer automates sampling, dilution, trypan blue staining and image analysis for bioreactor cultures, reporting viable cell density and viability with minimal handling. It is intended for CHO, hybridoma and insect cell process development and manufacturing support laboratories.

What is the Bioprocess Cell Viability Analyzer?

A bioprocess cell viability analyzer automates sampling, dilution, trypan blue staining and image analysis for bioreactor cultures, reporting viable cell density and viability with minimal handling. It is intended for CHO, hybridoma and insect cell process development and manufacturing support laboratories.

Overview

Bioprocess viability analyzers combine an autosampler, a dilution and staining module, a flow cell or cuvette, and image analysis software tailored to bioreactor samples. Cultures reach densities above 1 × 10⁷ cells/mL, so automated dilution is essential to keep cells within the counting range. The system mixes trypan blue with a diluted sample, images it in a flow cell, and reports viable cell density, viability percent, average diameter and aggregation. Some models accept tube racks for 10 to 40 samples, while others connect directly to bioreactors through sterile sampling ports. Data integration with process historians, LIMS or bioreactor control software via OPC or CSV is common. Reagent management and wash cycles limit carry-over between samples.

How does it work?

Cell analysis instruments use three main detection principles. Image-based counters photograph cells in a counting chamber, then software segments cells and classifies them as live or dead by dye exclusion, for example trypan blue, or by fluorescence with acridine orange and propidium iodide. Impedance counters, based on the Coulter principle, draw cells through a micro-aperture and record the electrical resistance pulse, whose amplitude is proportional to cell volume. Flow cytometers hydrodynamically focus cells into a single file past one or more lasers, detect forward and side scatter plus fluorescence through dichroic mirrors and bandpass filters, and convert photons to digital events with photomultiplier tubes or avalanche photodiodes. Software then gates populations and reports concentration, viability, size distribution and marker expression.

What are the key features?

  • Automated dilution handles cultures above 1 × 10⁷ cells/mL.
  • Autosampler for 10 to 40 tubes or bioreactor sampling connection.
  • Flow-cell imaging avoids manual slide loading and operator variability.
  • Reports viable cell density, viability, diameter and aggregation.
  • Data export through CSV, OPC or LIMS-compatible formats.
  • Audit trail, user levels and electronic records support regulated work.

What are the technical specifications?

A typical bioprocess cell viability analyzer configuration offers viable cell density range of 5 × 10⁴–2 × 10⁸ cells/mL, automated dilution of 1:1 to 1:100, sample volume of 100–500 μL, throughput of up to 40 samples per rack, time per sample of approx. 1–2 min and viability method of Trypan blue exclusion. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Bioprocess Cell Viability Analyzer is used in CHO and hybridoma bioreactor monitoring, fed-batch process development, cell line clone screening and manufacturing support laboratories. Across the wider Cell Analysis class, laboratories also deploy it for cell culture seeding and passaging, cell therapy product characterization and bioprocess viability monitoring.

Which standards and certifications apply?

Relevant standards and methods include IEC 61010-1, IEC 61010-2-101, IEC 61326-2-6, IEC 60825-1, ISO 13322-1 and ISO 13319. Certification candidates for this model are CE, ISO 9001 manufacturing and 21 CFR Part 11 software capability; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Cell analyzers need regular optical and fluidic verification. Image counters should be checked with count-bead or latex standards, and impedance counters with calibration particles at the aperture size. Flow cytometers require daily quality control with fluorescent beads, fluidic cleaning after each session and periodic laser alignment checks. Install flow cytometers away from vibration and heat, with stable power and, if needed, a waste decontamination procedure for biohazardous samples. Use consumables from the validated lot, handle cell suspensions gently to avoid clumping, and standardize dye concentrations and incubation times. Regulated laboratories should verify software access control and audit trail.

How do I select the right Bioprocess Cell Viability Analyzer?

Choose this analyzer for frequent bioreactor sampling at high density where manual dilution causes error and delay. Specify density range, sample volume, autosampler capacity, bioreactor interface, data integration and regulatory software needs. For occasional culture counting, a standard image-based counter is sufficient. Request demonstration data on your own samples before purchase.

How does it compare with other Cell Analysis variants?

Start with the question you need answered. For concentration and viability only, an image-based counter or impedance counter is fast and inexpensive. For immunophenotyping, cell cycle or apoptosis, you need a flow cytometer with the right lasers and detector channels for your fluorochromes. Consider sample characteristics: clumping, debris, primary cells or platelets affect image segmentation, and small particles require an impedance aperture of suitable diameter. Check the counting range in cells per mL and the sample volume required, especially for scarce samples. Review consumable costs, since slides or cartridges often dominate running costs. Confirm software features for data export, user control and audit trail, and whether the instrument supports the sample types used in cell therapy or bioprocess workflows.

Full specifications

Full specifications
Viable cell density range5 × 10⁴–2 × 10⁸ cells/mL
Automated dilution1:1 to 1:100
Sample volume100–500 μL
Throughputup to 40 samples per rack
Time per sampleapprox. 1–2 min
Viability methodTrypan blue exclusion
Cell diameter range5–50 μm
Precision (CV)below 5 % (typical)
Data interfaceCSV, OPC, LIMS
Power supply100–240 V, 50/60 Hz

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • CHO and hybridoma bioreactor monitoring
  • Fed-batch process development
  • Cell line clone screening
  • Manufacturing support laboratories

Key features

  • Automated dilution handles cultures above 1 × 10⁷ cells/mL.
  • Autosampler for 10 to 40 tubes or bioreactor sampling connection.
  • Flow-cell imaging avoids manual slide loading and operator variability.
  • Reports viable cell density, viability, diameter and aggregation.
  • Data export through CSV, OPC or LIMS-compatible formats.
  • Audit trail, user levels and electronic records support regulated work.

Frequently asked questions about Bioprocess Cell Viability Analyzer

Bioreactor cultures often exceed the optimal counting range, and manual serial dilution adds pipetting error. Automated dilution standardizes the ratio, reduces operator time and produces more reproducible viable cell density for feeding decisions and harvest timing.