Real-Time PCR System (96-Well)
实时荧光定量 PCR 系统(96 孔)
- SKU MOA-0001
- Molecular Analysis
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IEC 61010-2-010 test report (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Sample capacity | 96 × 0.2 mL wells |
|---|---|
| Reaction volume | 10–100 μL |
| Temperature range | 4–100 °C |
| Maximum ramp rate | up to 6 °C/s |
| Temperature uniformity | ±0.3 °C |
| Temperature accuracy | ±0.25 °C |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-010, IEC 61010-2-101
What is the Real-Time PCR System (96-Well)?
A 96-well real-time PCR system thermocycles up to 96 reactions while measuring fluorescence in each well every cycle, giving quantification, melt-curve and genotyping data. It is the standard choice for research laboratories running gene expression, pathogen detection and routine qPCR assays.
What is the Real-Time PCR System (96-Well)?
A 96-well real-time PCR system thermocycles up to 96 reactions while measuring fluorescence in each well every cycle, giving quantification, melt-curve and genotyping data. It is the standard choice for research laboratories running gene expression, pathogen detection and routine qPCR assays.
Overview
A 96-well real-time PCR system pairs a Peltier thermal block with an optical module containing LED or halogen excitation, filters and a CCD, CMOS or photodiode detector. Most configurations read four to six fluorescence channels, enabling multiplex assays with an internal control. Block ramp rates of 3 to 6 °C per second give runs of 40 cycles in roughly 40 to 90 minutes, and temperature uniformity of ±0.3 °C across the block supports reproducible Cq values. Software performs baseline correction, threshold setting, standard curve construction, relative quantification, melt-curve analysis, allelic discrimination and end-point genotyping. Gradient blocks are available on some models for annealing optimization. Standard 0.2 mL tubes, strips and plates are accepted, and heated lids prevent condensation.
How does it work?
Molecular analysis instruments amplify a nucleic acid target and monitor the reaction through fluorescence. In real-time PCR, a thermal block cycles between denaturation, annealing and extension, and optics read intercalating dyes such as SYBR Green or hydrolysis probes such as TaqMan at each cycle. The cycle at which fluorescence crosses a threshold, the quantification cycle (Cq), is inversely related to starting copy number, and a standard curve or comparative method gives relative or absolute quantity. Digital PCR partitions the reaction into thousands of nanoliter droplets or wells, amplifies each independently, and counts positive partitions; Poisson statistics then yield absolute copy number without calibration curves. Isothermal methods such as LAMP amplify at a constant temperature and detect fluorescence or turbidity. Melt-curve analysis verifies product specificity.
What are the key features?
- Four to six fluorescence channels support multiplexing with internal controls.
- Block uniformity of ±0.3 °C supports reproducible Cq values.
- Ramp rate of up to 6 °C/s shortens run time.
- Melt-curve, allelic discrimination and relative quantification software.
- Optional gradient block for annealing temperature optimization.
- Open platform accepts common dyes, probes and plastics.
What are the technical specifications?
A typical real-time pcr system (96-well) configuration offers sample capacity of 96 × 0.2 mL wells, reaction volume of 10–100 μL, temperature range of 4–100 °C, maximum ramp rate of up to 6 °C/s, temperature uniformity of ±0.3 °C and temperature accuracy of ±0.25 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Real-Time PCR System (96-Well) is used in gene expression profiling by qPCR, pathogen detection assay development, SNP genotyping and viral load research quantification. Across the wider Molecular Analysis class, laboratories also deploy it for gene expression analysis, pathogen detection assay development and viral vector and residual DNA quantification.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-010, IEC 61010-2-101, IEC 61326-2-6, ISO 20395, ISO 22174 and MIQE guidelines. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-2-010 test report; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Molecular instruments require careful contamination control: separate pre- and post-amplification areas, use filter tips and include no-template controls. Thermal block temperature accuracy and uniformity should be verified periodically with a calibrated temperature probe, and optical calibration with dye plates should be performed after installation and at intervals recommended by the manufacturer. Keep the instrument on a stable bench with adequate ventilation, and protect lamps or LEDs from unnecessary exposure. Follow MIQE guidance when reporting qPCR data, and keep raw fluorescence data archived. Regulated laboratories should confirm software access control and audit trail.
How do I select the right Real-Time PCR System (96-Well)?
Choose a 96-well system for routine qPCR with moderate throughput and multiplexing of up to four to six targets. Specify channels, ramp rate, uniformity, gradient capability, software features and reagent compatibility. Choose a 384-well system for screening volumes, or a digital PCR system for absolute rare-target quantification.
How does it compare with other Molecular Analysis variants?
Decide first between relative quantification, for which real-time PCR is usually sufficient, and absolute quantification of rare targets or small fold changes, for which digital PCR offers better precision. Match well format to throughput: 96-well suits routine work, and 384-well suits screening. Count optical channels against multiplex needs, since four to six channels are common for multiplex panels. Consider ramp rate and run time, block uniformity and lid heating for reproducibility. For field or point-of-need testing, portable analyzers with battery operation and lyophilized reagents are appropriate. Check reagent openness, software features for analysis and export, and whether the instrument can support the validation documents that regulated workflows require.
Full specifications
| Sample capacity | 96 × 0.2 mL wells |
|---|---|
| Reaction volume | 10–100 μL |
| Temperature range | 4–100 °C |
| Maximum ramp rate | up to 6 °C/s |
| Temperature uniformity | ±0.3 °C |
| Temperature accuracy | ±0.25 °C |
| Fluorescence channels | 4 or 6 |
| Excitation source | LED |
| Dynamic range | up to 10 logs |
| Power supply | 100–240 V, 50/60 Hz, approx. 800 W |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Gene expression profiling by qPCR
- Pathogen detection assay development
- SNP genotyping
- Viral load research quantification
Key features
- Four to six fluorescence channels support multiplexing with internal controls.
- Block uniformity of ±0.3 °C supports reproducible Cq values.
- Ramp rate of up to 6 °C/s shortens run time.
- Melt-curve, allelic discrimination and relative quantification software.
- Optional gradient block for annealing temperature optimization.
- Open platform accepts common dyes, probes and plastics.
Frequently asked questions about Real-Time PCR System (96-Well)
Acceptable efficiency is typically 90 to 110 percent, corresponding to a standard-curve slope between about −3.6 and −3.1, with R² above 0.98. Values outside this range suggest inhibition, poor primer design or pipetting problems and should be investigated.
SYBR Green is inexpensive and allows melt-curve analysis but detects any double-stranded DNA. Hydrolysis probes add specificity and enable multiplexing, but cost more and need separate assay design. Use probes for diagnostics-type assays and SYBR for gene expression screening.
Perform optical calibration (dye calibration) on installation and after lamp, LED or service events, and verify thermal accuracy annually or per quality system. Run a reference plate with known concentrations to track performance between calibrations.
It measures the amount of a specific DNA or RNA sequence in a sample by amplifying it and monitoring fluorescence. Results are reported as Cq values, relative expression, absolute copy number or presence/absence of a pathogen or genetic variant.
Use digital PCR when you need absolute copy number without standards, detection of rare variants below about 0.1 percent allele fraction, or small fold-change differences such as copy number variation. qPCR remains faster and cheaper for routine relative quantification and high-throughput screening.
The quantification cycle (Cq), also called Ct, is the PCR cycle at which fluorescence first rises above a set threshold. Lower Cq means more starting template, and each cycle difference corresponds to about a twofold change when amplification efficiency is near 100 percent.