Skip to main content
Lab Manufacturers China
Multimode Microplate Reader (Absorbance, Fluorescence, Luminescence) — product photo

Multimode Microplate Reader (Absorbance, Fluorescence, Luminescence)

多功能酶标仪(吸光度、荧光、发光)

  • SKU PRA-0002
  • Protein Analysis
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-2-101 test report (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Detection modesAbsorbance, FI, luminescence (options: FP, TRF)
Plate formats6- to 384-well (1536 optional)
Absorbance wavelength range230–1000 nm
Fluorescence excitation range250–800 nm
Bandwidth5–20 nm (selectable)
Fluorescein sensitivitybelow 1 pM (384-well, typical)
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-101, IEC 61326-2-6

What is the Multimode Microplate Reader (Absorbance, Fluorescence, Luminescence)?

A multimode microplate reader combines absorbance, fluorescence intensity and luminescence detection in one instrument, often with monochromator wavelength selection. It suits laboratories running varied assays, including protein quantification, reporter gene, cell viability and fluorescence-based binding studies on 96- to 384-well plates.

What is the Multimode Microplate Reader (Absorbance, Fluorescence, Luminescence)?

A multimode microplate reader combines absorbance, fluorescence intensity and luminescence detection in one instrument, often with monochromator wavelength selection. It suits laboratories running varied assays, including protein quantification, reporter gene, cell viability and fluorescence-based binding studies on 96- to 384-well plates.

Overview

A multimode reader contains separate optical paths for each detection mode. For absorbance, a xenon flash lamp and monochromator supply selectable wavelengths, usually 230 to 1000 nm with 1 to 5 nm bandwidth. Fluorescence intensity uses a separate excitation and emission monochromator or filter sets with top and bottom reading, and a photomultiplier tube detects the emission. Luminescence is read without excitation using a sensitive PMT in a light-tight chamber. Options frequently include fluorescence polarization, time-resolved fluorescence, injectors for flash luminescence assays, temperature control to 45 °C and gas control for live cells. Sensitivity specifications, such as fluorescein detection below 1 pM, distinguish models. Software supports kinetic and spectral scans, well-area scanning and preset protocols for common assays.

How does it work?

Protein analysis relies on several complementary physical principles. Microplate readers measure absorbance, fluorescence or luminescence from wells to quantify protein by colorimetric assays such as BCA and Bradford or to read ELISA signals, using monochromators or filters and photomultiplier tubes or photodiodes. Electrophoretic systems separate proteins by size, charge or isoelectric point; in capillary systems, SDS-coated proteins migrate through a sieving polymer under high voltage and are detected by UV absorbance or laser-induced fluorescence. Western blot imagers capture chemiluminescent or fluorescent signals from membranes using cooled CCD cameras with long exposure. Chromatography systems such as FPLC pump buffers through columns to bind and elute proteins by affinity, ion exchange or size exclusion, with UV, conductivity and pH monitors guiding fraction collection.

What are the key features?

  • Absorbance, fluorescence intensity and luminescence in one platform.
  • Monochromator selection from 230 to 1000 nm for flexible assay design.
  • Top and bottom fluorescence reading for cells and solutions.
  • Optional injectors, fluorescence polarization and time-resolved fluorescence.
  • Temperature control to 45 °C with optional gas control.
  • Well-scanning and kinetic modes with preset assay protocols.

What are the technical specifications?

A typical multimode microplate reader (absorbance, fluorescence, luminescence) configuration offers detection modes of Absorbance, FI, luminescence (options: FP, TRF), plate formats of 6- to 384-well (1536 optional), absorbance wavelength range of 230–1000 nm, fluorescence excitation range of 250–800 nm, bandwidth of 5–20 nm (selectable) and fluorescein sensitivity of below 1 pM (384-well, typical). Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Multimode Microplate Reader (Absorbance, Fluorescence, Luminescence) is used in luciferase reporter gene assays, cell viability and cytotoxicity assays, fluorescence binding and protein interaction studies and protein and nucleic acid quantification. Across the wider Protein Analysis class, laboratories also deploy it for ELISA and immunoassay readout, protein concentration determination and antibody purity and size variant analysis.

Which standards and certifications apply?

Relevant standards and methods include IEC 61010-1, IEC 61010-2-101, IEC 61326-2-6, USP <1053>, USP <1055>, Ph. Eur. 2.2.31 and ICH Q6B. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-2-101 test report; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Protein instruments depend on good sample handling: keep samples cold, use protease inhibitors and avoid repeated freeze-thaw cycles. Microplate readers need periodic verification of wavelength accuracy and absorbance linearity with reference filters or dye solutions. Capillary systems require clean buffers, filtered samples and replacement of cartridges on schedule. Imaging systems should be kept in a dust-free, temperature-stable location, and cameras need flat-field correction. FPLC columns must be stored in recommended solutions, and pump seals replaced regularly. Regulated laboratories should perform installation and operational qualification, and consider 21 CFR Part 11 compliant software.

How do I select the right Multimode Microplate Reader (Absorbance, Fluorescence, Luminescence)?

Select a multimode reader when one instrument must support varied assays across absorbance, fluorescence and luminescence. Specify wavelength selection type, sensitivity targets, injectors, temperature and gas control, and plate formats. An absorbance-only reader is adequate and cheaper for ELISA-only laboratories.

How does it compare with other Protein Analysis variants?

Define the analytical goal first: quantification and ELISA point to microplate readers, purity and size variants to capillary electrophoresis, expression and semi-quantitative detection to Western blot imaging, and isolation of milligram quantities to chromatography systems. Check sensitivity and dynamic range against your lowest expected signal, for example pg/mL for ELISA or ng per band for blotting. Consider throughput and automation, such as 96-sample capillary runs or plate stackers. For purification, specify column pressure limits, flow rate range and detector options. Confirm compatibility with your assay formats and reagents, and evaluate software for data integrity, regulatory audit trail and export. Factor in consumable costs, such as capillary cartridges or detection reagents, and available training.

Full specifications

Full specifications
Detection modesAbsorbance, FI, luminescence (options: FP, TRF)
Plate formats6- to 384-well (1536 optional)
Absorbance wavelength range230–1000 nm
Fluorescence excitation range250–800 nm
Bandwidth5–20 nm (selectable)
Fluorescein sensitivitybelow 1 pM (384-well, typical)
Luminescence dynamic rangeup to 8 decades
Temperature controlambient +4 to 45 °C
InjectorsUp to 2 (optional)
Power supply100–240 V, 50/60 Hz

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Luciferase reporter gene assays
  • Cell viability and cytotoxicity assays
  • Fluorescence binding and protein interaction studies
  • Protein and nucleic acid quantification

Key features

  • Absorbance, fluorescence intensity and luminescence in one platform.
  • Monochromator selection from 230 to 1000 nm for flexible assay design.
  • Top and bottom fluorescence reading for cells and solutions.
  • Optional injectors, fluorescence polarization and time-resolved fluorescence.
  • Temperature control to 45 °C with optional gas control.
  • Well-scanning and kinetic modes with preset assay protocols.

Frequently asked questions about Multimode Microplate Reader (Absorbance, Fluorescence, Luminescence)

Top reading excites and collects from above the well and suits solutions. Bottom reading uses optics beneath the plate and suits adherent cells, reducing interference from the medium. Bottom reading requires clear-bottom plates and typically black walls to limit crosstalk.

Related models

All Protein Analysis

Request a quotation for the Multimode Microplate Reader (Absorbance, Fluorescence, Luminescence)

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote