Capillary Electrophoresis Protein Analyzer

毛细管电泳蛋白分析仪

  • SKU PRA-0003
  • Protein Analysis
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • 21 CFR Part 11 software capability (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Separation modesCE-SDS, cIEF, CZE
Maximum voltage±30 kV
DetectionUV 200–280 nm; LIF optional
Capillary temperature control15–60 °C, ±0.1 °C
Sample capacity48–96 vials/wells
Sample volumeapprox. 10–50 μL
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-101, IEC 61326-2-6

What is the Capillary Electrophoresis Protein Analyzer?

A capillary electrophoresis protein analyzer separates proteins in fused-silica capillaries by size (CE-SDS), charge or isoelectric point (cIEF), with UV or fluorescence detection. It is used in biopharmaceutical laboratories for quantitative purity, fragment and charge variant analysis of monoclonal antibodies and recombinant proteins.

What is the Capillary Electrophoresis Protein Analyzer?

A capillary electrophoresis protein analyzer separates proteins in fused-silica capillaries by size (CE-SDS), charge or isoelectric point (cIEF), with UV or fluorescence detection. It is used in biopharmaceutical laboratories for quantitative purity, fragment and charge variant analysis of monoclonal antibodies and recombinant proteins.

Overview

A capillary electrophoresis analyzer includes a high-voltage power supply up to 30 kV, a capillary cartridge with temperature control, autosampler trays, and UV or laser-induced fluorescence detection. In CE-SDS, proteins are denatured with SDS and migrate through a sieving polymer, separating by molecular weight in 20 to 40 minutes. In cIEF, proteins focus in a pH gradient formed by carrier ampholytes and are detected at their isoelectric points, resolving charge variants such as deamidated or sialylated forms. Reproducibility is typically better than 1 percent RSD for migration times, and peak area precision of 1 to 2 percent supports quantitative purity. Automation allows overnight runs of 48 to 96 samples. Validated methods can support ICH Q6B release and stability testing. Consumables include capillaries, gels and ampholytes.

How does it work?

Protein analysis relies on several complementary physical principles. Microplate readers measure absorbance, fluorescence or luminescence from wells to quantify protein by colorimetric assays such as BCA and Bradford or to read ELISA signals, using monochromators or filters and photomultiplier tubes or photodiodes. Electrophoretic systems separate proteins by size, charge or isoelectric point; in capillary systems, SDS-coated proteins migrate through a sieving polymer under high voltage and are detected by UV absorbance or laser-induced fluorescence. Western blot imagers capture chemiluminescent or fluorescent signals from membranes using cooled CCD cameras with long exposure. Chromatography systems such as FPLC pump buffers through columns to bind and elute proteins by affinity, ion exchange or size exclusion, with UV, conductivity and pH monitors guiding fraction collection.

What are the key features?

  • High-voltage supply up to 30 kV with capillary temperature control.
  • Supports CE-SDS, cIEF and capillary zone electrophoresis modes.
  • UV absorbance with optional laser-induced fluorescence detection.
  • Autosampler for 48 to 96 samples supports overnight runs.
  • Migration time precision better than 1 percent RSD.
  • Audit-trail-capable software for regulated release testing.

What are the technical specifications?

A typical capillary electrophoresis protein analyzer configuration offers separation modes of CE-SDS, cIEF, CZE, maximum voltage of ±30 kV, detection of UV 200–280 nm; LIF optional, capillary temperature control of 15–60 °C, ±0.1 °C, sample capacity of 48–96 vials/wells and sample volume of approx. 10–50 μL. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Capillary Electrophoresis Protein Analyzer is used in monoclonal antibody purity by CE-SDS, charge variant profiling by cIEF, biosimilar comparability studies and process development and stability studies. Across the wider Protein Analysis class, laboratories also deploy it for ELISA and immunoassay readout, protein concentration determination and antibody purity and size variant analysis.

Which standards and certifications apply?

Relevant standards and methods include IEC 61010-1, IEC 61010-2-101, IEC 61326-2-6, USP <1053>, USP <1055>, Ph. Eur. 2.2.31 and ICH Q6B. Certification candidates for this model are CE, ISO 9001 manufacturing and 21 CFR Part 11 software capability; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Protein instruments depend on good sample handling: keep samples cold, use protease inhibitors and avoid repeated freeze-thaw cycles. Microplate readers need periodic verification of wavelength accuracy and absorbance linearity with reference filters or dye solutions. Capillary systems require clean buffers, filtered samples and replacement of cartridges on schedule. Imaging systems should be kept in a dust-free, temperature-stable location, and cameras need flat-field correction. FPLC columns must be stored in recommended solutions, and pump seals replaced regularly. Regulated laboratories should perform installation and operational qualification, and consider 21 CFR Part 11 compliant software.

How do I select the right Capillary Electrophoresis Protein Analyzer?

Choose a CE protein analyzer for quantitative purity and charge variant work in biopharma, where gels lack precision and automation. Specify modes, detectors, sample capacity, consumable cartridges and software compliance. For simple expression checks, conventional gels and Western blotting remain more economical.

How does it compare with other Protein Analysis variants?

Define the analytical goal first: quantification and ELISA point to microplate readers, purity and size variants to capillary electrophoresis, expression and semi-quantitative detection to Western blot imaging, and isolation of milligram quantities to chromatography systems. Check sensitivity and dynamic range against your lowest expected signal, for example pg/mL for ELISA or ng per band for blotting. Consider throughput and automation, such as 96-sample capillary runs or plate stackers. For purification, specify column pressure limits, flow rate range and detector options. Confirm compatibility with your assay formats and reagents, and evaluate software for data integrity, regulatory audit trail and export. Factor in consumable costs, such as capillary cartridges or detection reagents, and available training.

Full specifications

Full specifications
Separation modesCE-SDS, cIEF, CZE
Maximum voltage±30 kV
DetectionUV 200–280 nm; LIF optional
Capillary temperature control15–60 °C, ±0.1 °C
Sample capacity48–96 vials/wells
Sample volumeapprox. 10–50 μL
Migration time precisionbelow 1 % RSD
Peak area precision1–2 % RSD
Run time (CE-SDS)20–40 min
Power supply100–240 V, 50/60 Hz

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Monoclonal antibody purity by CE-SDS
  • Charge variant profiling by cIEF
  • Biosimilar comparability studies
  • Process development and stability studies

Key features

  • High-voltage supply up to 30 kV with capillary temperature control.
  • Supports CE-SDS, cIEF and capillary zone electrophoresis modes.
  • UV absorbance with optional laser-induced fluorescence detection.
  • Autosampler for 48 to 96 samples supports overnight runs.
  • Migration time precision better than 1 percent RSD.
  • Audit-trail-capable software for regulated release testing.

Frequently asked questions about Capillary Electrophoresis Protein Analyzer

CE-SDS provides quantitative, automated and reproducible results with on-capillary detection, avoiding staining variability of gels. It separates reduced and non-reduced antibody fragments with high resolution, which is why it is widely used for release and stability testing.

Related models

All Protein Analysis

Request a quotation for the Capillary Electrophoresis Protein Analyzer

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.