Isothermal Amplification Fluorescence Detector — product photo

Isothermal Amplification Fluorescence Detector

等温扩增荧光检测仪

  • SKU MOA-0005
  • Molecular Analysis
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Sample capacity8–48 tubes
Temperature range35–70 °C
Temperature stability±0.2 °C
Reaction volume10–25 μL
Fluorescence channels1–2 (FAM/SYBR-type)
Time to result15–40 min (LAMP)
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-010, IEC 61010-2-101

What is the Isothermal Amplification Fluorescence Detector?

An isothermal amplification fluorescence detector holds reactions at a constant temperature, typically 60 to 65 °C for LAMP, while monitoring fluorescence in real time. It offers simple, fast nucleic acid detection without thermal cycling, suited to field screening, low-resource laboratories and rapid assay development.

What is the Isothermal Amplification Fluorescence Detector?

An isothermal amplification fluorescence detector holds reactions at a constant temperature, typically 60 to 65 °C for LAMP, while monitoring fluorescence in real time. It offers simple, fast nucleic acid detection without thermal cycling, suited to field screening, low-resource laboratories and rapid assay development.

Overview

Isothermal amplification methods such as loop-mediated isothermal amplification (LAMP) and recombinase polymerase amplification (RPA) use strand-displacing polymerases or recombinase systems to amplify targets at constant temperature, removing the need for rapid thermal cycling. The detector comprises a precisely controlled heating block, typically 35 to 70 °C, and an optical module that reads fluorescent intercalating dyes or quenched probes, often in one to two channels. Time to positive, expressed in minutes, replaces Cq, and most LAMP assays give results in 15 to 40 minutes. Simple instrument construction keeps cost low and enables battery operation. Because LAMP uses four to six primers and produces large amounts of amplicon, carryover contamination risk is high, so closed-tube detection and strict workflow separation are essential.

How does it work?

Molecular analysis instruments amplify a nucleic acid target and monitor the reaction through fluorescence. In real-time PCR, a thermal block cycles between denaturation, annealing and extension, and optics read intercalating dyes such as SYBR Green or hydrolysis probes such as TaqMan at each cycle. The cycle at which fluorescence crosses a threshold, the quantification cycle (Cq), is inversely related to starting copy number, and a standard curve or comparative method gives relative or absolute quantity. Digital PCR partitions the reaction into thousands of nanoliter droplets or wells, amplifies each independently, and counts positive partitions; Poisson statistics then yield absolute copy number without calibration curves. Isothermal methods such as LAMP amplify at a constant temperature and detect fluorescence or turbidity. Melt-curve analysis verifies product specificity.

What are the key features?

  • Constant-temperature block from about 35 to 70 °C suits LAMP and RPA.
  • Real-time fluorescence reading reports time to positive in minutes.
  • Simple mechanics allow compact, low-power and battery-capable designs.
  • Typical LAMP results appear in 15 to 40 minutes.
  • Closed-tube detection limits amplicon carryover contamination.
  • Multiple independent heating positions allow different temperatures per tube.

What are the technical specifications?

A typical isothermal amplification fluorescence detector configuration offers sample capacity of 8–48 tubes, temperature range of 35–70 °C, temperature stability of ±0.2 °C, reaction volume of 10–25 μL, fluorescence channels of 1–2 (FAM/SYBR-type) and time to result of 15–40 min (LAMP). Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Isothermal Amplification Fluorescence Detector is used in LAMP-based pathogen screening, food and GMO rapid screening, plant and animal disease detection and isothermal assay development. Across the wider Molecular Analysis class, laboratories also deploy it for gene expression analysis, pathogen detection assay development and viral vector and residual DNA quantification.

Which standards and certifications apply?

Relevant standards and methods include IEC 61010-1, IEC 61010-2-010, IEC 61010-2-101, IEC 61326-2-6, ISO 20395, ISO 22174 and MIQE guidelines. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Molecular instruments require careful contamination control: separate pre- and post-amplification areas, use filter tips and include no-template controls. Thermal block temperature accuracy and uniformity should be verified periodically with a calibrated temperature probe, and optical calibration with dye plates should be performed after installation and at intervals recommended by the manufacturer. Keep the instrument on a stable bench with adequate ventilation, and protect lamps or LEDs from unnecessary exposure. Follow MIQE guidance when reporting qPCR data, and keep raw fluorescence data archived. Regulated laboratories should confirm software access control and audit trail.

How do I select the right Isothermal Amplification Fluorescence Detector?

Choose an isothermal detector for rapid, simple screening with LAMP or RPA assays, or for settings where thermal cyclers are impractical. Specify temperature range, channels, tube capacity and power options. For quantification with broad assay menus, a real-time PCR system offers better precision and multiplexing.

How does it compare with other Molecular Analysis variants?

Decide first between relative quantification, for which real-time PCR is usually sufficient, and absolute quantification of rare targets or small fold changes, for which digital PCR offers better precision. Match well format to throughput: 96-well suits routine work, and 384-well suits screening. Count optical channels against multiplex needs, since four to six channels are common for multiplex panels. Consider ramp rate and run time, block uniformity and lid heating for reproducibility. For field or point-of-need testing, portable analyzers with battery operation and lyophilized reagents are appropriate. Check reagent openness, software features for analysis and export, and whether the instrument can support the validation documents that regulated workflows require.

Full specifications

Full specifications
Sample capacity8–48 tubes
Temperature range35–70 °C
Temperature stability±0.2 °C
Reaction volume10–25 μL
Fluorescence channels1–2 (FAM/SYBR-type)
Time to result15–40 min (LAMP)
Read interval15–60 s
Heating position controlIndependent per position (optional)
PowerUSB-C or 12 V, optional battery
ConnectivityUSB, Wi-Fi

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • LAMP-based pathogen screening
  • Food and GMO rapid screening
  • Plant and animal disease detection
  • Isothermal assay development

Key features

  • Constant-temperature block from about 35 to 70 °C suits LAMP and RPA.
  • Real-time fluorescence reading reports time to positive in minutes.
  • Simple mechanics allow compact, low-power and battery-capable designs.
  • Typical LAMP results appear in 15 to 40 minutes.
  • Closed-tube detection limits amplicon carryover contamination.
  • Multiple independent heating positions allow different temperatures per tube.

Frequently asked questions about Isothermal Amplification Fluorescence Detector

LAMP amplifies DNA at a constant temperature, around 60 to 65 °C, using a strand-displacing polymerase and four to six primers, and is often complete in under 40 minutes. PCR cycles temperature and uses two primers, offering better multiplexing and established quantification methods.