What are Triple Quadrupole MS?

A triple quadrupole mass spectrometer uses two mass-filtering quadrupoles separated by a collision cell to isolate a precursor ion, fragment it and monitor selected product ions. It delivers selective, sensitive quantitation in complex matrices and is used in clinical, bioanalytical, food safety and environmental laboratories.

5 models of Triple Quadrupole MS

The 5 models below are current configurations; specifications are confirmed on quotation.

Benchtop Triple Quadrupole LC-MS/MS System for Clinical Quantitation

用于临床定量的台式三重四极杆液相色谱串联质谱系统

  • TQM-0001
  • Triple Quadrupole MS
  • CE (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
Mass range:
m/z 5–1250
Scan speed:
up to 10,000 Da/s
Minimum dwell time:
≥ 2 ms
Polarity switching time:
≤ 25 ms
Sensitivity (reserpine, m/z 609→195):
S/N > 1000:1 for 1 pg on column
Linear dynamic range:
4–5 orders of magnitude

A compact benchtop LC-MS/MS system built for routine clinical quantitation such as therapeutic drug monitoring, steroid hormones and vitamin D. It favors robustness, small footprint and simple operation over the ultimate sensitivity of larger research platforms.

Request a quote
View details

High-Sensitivity Triple Quadrupole LC-MS/MS for Bioanalysis

用于生物分析的高灵敏度三重四极杆液相色谱串联质谱仪

  • TQM-0002
  • Triple Quadrupole MS
  • CE (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Mass range:
m/z 2–2000
Scan speed:
up to 20,000 Da/s
Minimum dwell time:
≤ 1 ms
Polarity switching time:
≤ 5 ms
Sensitivity (reserpine, m/z 609→195):
S/N > 10,000:1 for 1 pg on column
MRM transitions per second:
up to 500

A high-sensitivity triple quadrupole LC-MS/MS system with enhanced ion transmission and fast MRM for regulated bioanalysis, pharmacokinetics and peptide or oligonucleotide quantitation. It targets sub-picogram limits in plasma, serum, urine and tissue extracts.

Request a quote
View details

Triple Quadrupole GC-MS/MS System

三重四极杆气相色谱串联质谱系统

  • TQM-0003
  • Triple Quadrupole MS
  • CE (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Mass range:
m/z 1.2–1200
Ionization mode:
EI (70 eV); CI optional
Source temperature:
150–350 °C
Transfer line temperature:
up to 350 °C
Minimum dwell time:
≥ 1 ms
IDL (octafluoronaphthalene, m/z 272→222):
≤ 10 fg on column

A triple quadrupole GC-MS/MS system couples a capillary gas chromatograph with an electron-ionization source and MRM detection. It is the preferred tool for trace quantitation of volatile and semi-volatile compounds such as pesticides, PAHs, dioxins and PCBs in complex matrices.

Request a quote
View details

Triple Quadrupole ICP-MS (ICP-MS/MS) System

三重四极杆电感耦合等离子体质谱(ICP-MS/MS)系统

  • TQM-0004
  • Triple Quadrupole MS
  • CE (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Mass range:
m/z 2–260
Detection limit (As, O2 mode):
< 1 ng/L
Background equivalent concentration (S, O2 mode):
< 100 ng/L
Abundance sensitivity:
< 1 × 10⁻¹⁰ at m/z ±1
Sensitivity (Y-89):
> 500 Mcps/ppm
Oxide ratio (CeO/Ce):
< 1.5%

A triple quadrupole ICP-MS, or ICP-MS/MS, places a mass-selecting quadrupole before the reaction cell so that only the target mass enters it. This gives controlled reaction chemistry and removes polyatomic and isobaric interferences for trace elements such as sulfur, phosphorus, arsenic and selenium.

Request a quote
View details

Triple Quadrupole LC-MS/MS System for Food Safety and Residue Analysis

用于食品安全和残留分析的三重四极杆液相色谱串联质谱系统

  • TQM-0005
  • Triple Quadrupole MS
  • CE (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Mass range:
m/z 5–1500
Scan speed:
up to 15,000 Da/s
Minimum dwell time:
≥ 2 ms
Polarity switching time:
≤ 15 ms
MRM transitions per run:
600+ (scheduled)
Typical LOQ (pesticides):
1–10 µg/kg in QuEChERS extract

A triple quadrupole LC-MS/MS configured for food safety and residue testing, with large scheduled MRM libraries, matrix-robust source design and confirmation workflows. It supports multiresidue pesticide, veterinary drug, mycotoxin and contaminant screening to regulatory limits.

Request a quote
View details

Compare Triple Quadrupole MS models

ModelMass rangeScan speedMinimum dwell timePolarity switching timeSensitivity (reserpine, m/z 609→195)
Benchtop Triple Quadrupole LC-MS/MS System for Clinical QuantitationTQM-0001m/z 5–1250up to 10,000 Da/s≥ 2 ms≤ 25 msS/N > 1000:1 for 1 pg on column
High-Sensitivity Triple Quadrupole LC-MS/MS for BioanalysisTQM-0002m/z 2–2000up to 20,000 Da/s≤ 1 ms≤ 5 msS/N > 10,000:1 for 1 pg on column
Triple Quadrupole GC-MS/MS SystemTQM-0003m/z 1.2–1200up to 20,000 Da/s≥ 1 ms——
Triple Quadrupole ICP-MS (ICP-MS/MS) SystemTQM-0004m/z 2–260————
Triple Quadrupole LC-MS/MS System for Food Safety and Residue AnalysisTQM-0005m/z 5–1500up to 15,000 Da/s≥ 2 ms≤ 15 ms—

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do Triple Quadrupole MS work?

A triple quadrupole has three sections in series. The first quadrupole (Q1) transmits only ions of a chosen mass-to-charge ratio. The second section (q2) is a collision cell filled with nitrogen or argon at low pressure, where the selected precursor ions are accelerated and fragmented by collision-induced dissociation. The third quadrupole (Q3) then transmits only chosen product ions to the detector, usually an electron multiplier. Operating Q1 and Q3 at fixed masses gives multiple reaction monitoring (MRM), which filters out most chemical noise and gives very selective quantitation. Other scan modes include product-ion scan, precursor-ion scan and neutral-loss scan. The instrument is normally coupled to a liquid chromatograph through an electrospray or APCI source, or to a gas chromatograph through an electron-ionization source. Ion guides, a vacuum system with turbomolecular pumps and a data system for scheduled MRM complete the design.

Which Triple Quadrupole MS variants are available?

  • Benchtop Triple Quadrupole LC-MS/MS System for Clinical Quantitation — A compact benchtop LC-MS/MS system built for routine clinical quantitation such as therapeutic drug monitoring, steroid hormones and vitamin D.
  • High-Sensitivity Triple Quadrupole LC-MS/MS for Bioanalysis — A high-sensitivity triple quadrupole LC-MS/MS system with enhanced ion transmission and fast MRM for regulated bioanalysis, pharmacokinetics and peptide or oligonucleotide quantitation.
  • Triple Quadrupole GC-MS/MS System — A triple quadrupole GC-MS/MS system couples a capillary gas chromatograph with an electron-ionization source and MRM detection.
  • Triple Quadrupole ICP-MS (ICP-MS/MS) System — A triple quadrupole ICP-MS, or ICP-MS/MS, places a mass-selecting quadrupole before the reaction cell so that only the target mass enters it.
  • Triple Quadrupole LC-MS/MS System for Food Safety and Residue Analysis — A triple quadrupole LC-MS/MS configured for food safety and residue testing, with large scheduled MRM libraries, matrix-robust source design and confirmation workflows.

How do I choose the right variant?

Start with the sample introduction technique, because it decides the source and the chromatograph: LC-MS/MS for polar, non-volatile or thermally labile analytes, GC-MS/MS for volatile and semi-volatile compounds, and ICP-MS/MS for elemental analysis. Next define the required limit of quantitation in the final matrix, not the instrument sensitivity on a neat standard, and the number of MRM transitions per run, since a fast scheduled method needs dwell times of a few milliseconds and rapid polarity switching. Consider the dynamic range needed, typically four to six orders of magnitude, and the robustness of the source and ion optics under dirty matrices. Check the vendor's regulated-data software features if the laboratory works under GLP, GMP or 21 CFR Part 11 expectations. Finally compare the total cost of ownership, including vacuum pumps, nitrogen generator demand, service and column consumption.

Where are Triple Quadrupole MS used?

Triple Quadrupole MS are specified in clinical and therapeutic drug monitoring, pharmacokinetic and bioanalytical studies, pesticide and veterinary drug residue testing, environmental trace contaminant analysis, forensic and toxicology screening and metabolomics targeted panels.

Which standards and certifications apply?

Work with Triple Quadrupole MS is commonly governed by ICH M10, FDA Bioanalytical Method Validation Guidance, EU Commission Decision 2002/657/EC, SANTE/11312/2021, ISO 17025 and CLSI C62. Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

Install the system in a temperature-stable room with clean, stable power and adequate floor loading for the instrument and its rotary or dry backing pumps. Supply nitrogen of sufficient purity and flow for the source and collision gas, and high-purity argon where required. Exhaust from the source and pumps must be vented safely. Perform mass calibration and tuning on a routine schedule, and run system suitability injections before each batch. Source cleaning, ion-guide maintenance and pump-oil or seal changes are the main preventive tasks. Laboratories working under regulated frameworks should plan installation, operational and performance qualification, audit-trail review and method validation according to ICH M10 or equivalent guidance.

Frequently asked questions about Triple Quadrupole MS

It measures selected precursor-to-product ion transitions, typically in multiple reaction monitoring mode. Because both the parent ion and a characteristic fragment must match, the instrument can quantify target compounds at trace levels in complex samples such as plasma, food extracts or soil with low interference.