Triple Quadrupole LC-MS/MS System for Food Safety and Residue Analysis — product photo

Triple Quadrupole LC-MS/MS System for Food Safety and Residue Analysis

用于食品安全和残留分析的三重四极杆液相色谱串联质谱系统

  • SKU TQM-0005
  • Triple Quadrupole MS
  • CE (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Mass rangem/z 5–1500
Scan speedup to 15,000 Da/s
Minimum dwell time≥ 2 ms
Polarity switching time≤ 15 ms
MRM transitions per run600+ (scheduled)
Typical LOQ (pesticides)1–10 µg/kg in QuEChERS extract
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ICH M10, FDA Bioanalytical Method Validation Guidance, EU Commission Decision 2002/657/EC

What is the Triple Quadrupole LC-MS/MS System for Food Safety and Residue Analysis?

A triple quadrupole LC-MS/MS configured for food safety and residue testing, with large scheduled MRM libraries, matrix-robust source design and confirmation workflows. It supports multiresidue pesticide, veterinary drug, mycotoxin and contaminant screening to regulatory limits.

What is the Triple Quadrupole LC-MS/MS System for Food Safety and Residue Analysis?

A triple quadrupole LC-MS/MS configured for food safety and residue testing, with large scheduled MRM libraries, matrix-robust source design and confirmation workflows. It supports multiresidue pesticide, veterinary drug, mycotoxin and contaminant screening to regulatory limits.

Overview

This variant is tuned for high-throughput laboratories that test hundreds of samples a week against maximum residue limits. The source tolerates repeated injections of QuEChERS extracts, and the software holds compound databases with pre-optimized MRM transitions and retention times for several hundred pesticides, veterinary drugs and mycotoxins. Two transitions per analyte plus ion-ratio tolerance support confirmation according to European and Codex guidance. Fast polarity switching lets positive and negative ionization compounds run in the same injection. Typical limits of quantitation are 1 to 10 micrograms per kilogram, well below most regulatory limits. Matrix effects are managed with matrix-matched calibration or isotope-labeled internal standards. Automated batch reporting flags samples above limits and ion-ratio failures, reducing manual data review.

How does it work?

A triple quadrupole has three sections in series. The first quadrupole (Q1) transmits only ions of a chosen mass-to-charge ratio. The second section (q2) is a collision cell filled with nitrogen or argon at low pressure, where the selected precursor ions are accelerated and fragmented by collision-induced dissociation. The third quadrupole (Q3) then transmits only chosen product ions to the detector, usually an electron multiplier. Operating Q1 and Q3 at fixed masses gives multiple reaction monitoring (MRM), which filters out most chemical noise and gives very selective quantitation. Other scan modes include product-ion scan, precursor-ion scan and neutral-loss scan. The instrument is normally coupled to a liquid chromatograph through an electrospray or APCI source, or to a gas chromatograph through an electron-ionization source. Ion guides, a vacuum system with turbomolecular pumps and a data system for scheduled MRM complete the design.

What are the key features?

  • Pre-optimized MRM libraries covering several hundred pesticides, veterinary drugs and mycotoxins
  • Matrix-robust source and curtain-gas design to tolerate repeated QuEChERS extract injections
  • Two-transition confirmation with automatic ion-ratio tolerance checks per analyte
  • Fast polarity switching to run positive and negative compounds in one injection
  • Batch reporting with limit exceedance flags and retention-time verification
  • Optional dilute-and-shoot workflow and online cleanup interfaces for higher throughput

What are the technical specifications?

A typical triple quadrupole lc-ms/ms system for food safety and residue analysis configuration offers mass range of m/z 5–1500, scan speed of up to 15,000 Da/s, minimum dwell time of ≥ 2 ms, polarity switching time of ≤ 15 ms, MRM transitions per run of 600+ (scheduled) and typical LOQ (pesticides) of 1–10 µg/kg in QuEChERS extract. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Triple Quadrupole LC-MS/MS System for Food Safety and Residue Analysis is used in multiresidue pesticide screening, veterinary drug residues in meat and milk, mycotoxin quantitation in grain, natural toxins and plant growth regulators and import and export inspection laboratories. Across the wider Triple Quadrupole MS class, laboratories also deploy it for clinical and therapeutic drug monitoring, pharmacokinetic and bioanalytical studies and pesticide and veterinary drug residue testing.

Which standards and certifications apply?

Relevant standards and methods include ICH M10, FDA Bioanalytical Method Validation Guidance, EU Commission Decision 2002/657/EC, SANTE/11312/2021, ISO 17025 and CLSI C62. Certification candidates for this model are CE, IEC 61010-1 safety and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install the system in a temperature-stable room with clean, stable power and adequate floor loading for the instrument and its rotary or dry backing pumps. Supply nitrogen of sufficient purity and flow for the source and collision gas, and high-purity argon where required. Exhaust from the source and pumps must be vented safely. Perform mass calibration and tuning on a routine schedule, and run system suitability injections before each batch. Source cleaning, ion-guide maintenance and pump-oil or seal changes are the main preventive tasks. Laboratories working under regulated frameworks should plan installation, operational and performance qualification, audit-trail review and method validation according to ICH M10 or equivalent guidance.

How do I select the right Triple Quadrupole LC-MS/MS System for Food Safety and Residue Analysis?

Choose this variant for accredited food and feed laboratories running multiresidue methods at high throughput. A clinical benchtop or bioanalytical system can work if the compound list is small, but a large MRM library and matrix-robust source reduce maintenance. In an RFQ specify target commodities, analyte count, required LOQs against local MRLs, libraries needed and sample throughput.

How does it compare with other Triple Quadrupole MS variants?

Start with the sample introduction technique, because it decides the source and the chromatograph: LC-MS/MS for polar, non-volatile or thermally labile analytes, GC-MS/MS for volatile and semi-volatile compounds, and ICP-MS/MS for elemental analysis. Next define the required limit of quantitation in the final matrix, not the instrument sensitivity on a neat standard, and the number of MRM transitions per run, since a fast scheduled method needs dwell times of a few milliseconds and rapid polarity switching. Consider the dynamic range needed, typically four to six orders of magnitude, and the robustness of the source and ion optics under dirty matrices. Check the vendor's regulated-data software features if the laboratory works under GLP, GMP or 21 CFR Part 11 expectations. Finally compare the total cost of ownership, including vacuum pumps, nitrogen generator demand, service and column consumption.

Full specifications

Full specifications
Mass rangem/z 5–1500
Scan speedup to 15,000 Da/s
Minimum dwell time≥ 2 ms
Polarity switching time≤ 15 ms
MRM transitions per run600+ (scheduled)
Typical LOQ (pesticides)1–10 µg/kg in QuEChERS extract
Linear dynamic range4–5 orders of magnitude
Injection-to-injection cycle time10–15 min per sample
Ion sourceESI with APCI option
Compound library500+ pre-set transitions

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Multiresidue pesticide screening
  • Veterinary drug residues in meat and milk
  • Mycotoxin quantitation in grain
  • Natural toxins and plant growth regulators
  • Import and export inspection laboratories

Key features

  • Pre-optimized MRM libraries covering several hundred pesticides, veterinary drugs and mycotoxins
  • Matrix-robust source and curtain-gas design to tolerate repeated QuEChERS extract injections
  • Two-transition confirmation with automatic ion-ratio tolerance checks per analyte
  • Fast polarity switching to run positive and negative compounds in one injection
  • Batch reporting with limit exceedance flags and retention-time verification
  • Optional dilute-and-shoot workflow and online cleanup interfaces for higher throughput

Frequently asked questions about Triple Quadrupole LC-MS/MS System for Food Safety and Residue Analysis

With scheduled MRM and two transitions per compound, a single 12 to 15 minute method can cover roughly 300 to 500 pesticides and veterinary drugs, depending on dwell time and peak width. Very large lists are often split into two methods or two polarities.

Request a quotation for the Triple Quadrupole LC-MS/MS System for Food Safety and Residue Analysis