Triple Quadrupole GC-MS/MS System

三重四极杆气相色谱串联质谱系统

  • SKU TQM-0003
  • Triple Quadrupole MS
  • CE (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Mass rangem/z 1.2–1200
Ionization modeEI (70 eV); CI optional
Source temperature150–350 °C
Transfer line temperatureup to 350 °C
Minimum dwell time≥ 1 ms
IDL (octafluoronaphthalene, m/z 272→222)≤ 10 fg on column
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ICH M10, FDA Bioanalytical Method Validation Guidance, EU Commission Decision 2002/657/EC

What is the Triple Quadrupole GC-MS/MS System?

A triple quadrupole GC-MS/MS system couples a capillary gas chromatograph with an electron-ionization source and MRM detection. It is the preferred tool for trace quantitation of volatile and semi-volatile compounds such as pesticides, PAHs, dioxins and PCBs in complex matrices.

What is the Triple Quadrupole GC-MS/MS System?

A triple quadrupole GC-MS/MS system couples a capillary gas chromatograph with an electron-ionization source and MRM detection. It is the preferred tool for trace quantitation of volatile and semi-volatile compounds such as pesticides, PAHs, dioxins and PCBs in complex matrices.

Overview

In this variant the front end is a gas chromatograph with split/splitless or programmable temperature vaporizing injection, feeding a heated transfer line into an electron-ionization source at 70 eV. Hard ionization produces reproducible fragments, which the first quadrupole filters as precursors before collision-induced dissociation with nitrogen and helium quench gas. MRM then removes most matrix background, so detection limits in food or soil extracts can be an order of magnitude lower than with single-quadrupole selected ion monitoring. Source temperature is typically 230 to 350 degrees Celsius, and modern systems use an inert or self-cleaning source to maintain response for active compounds. Timed MRM allows several hundred transitions per run, suitable for multiresidue pesticide screens. Helium supply or a hydrogen-compatible source should be considered during planning.

How does it work?

A triple quadrupole has three sections in series. The first quadrupole (Q1) transmits only ions of a chosen mass-to-charge ratio. The second section (q2) is a collision cell filled with nitrogen or argon at low pressure, where the selected precursor ions are accelerated and fragmented by collision-induced dissociation. The third quadrupole (Q3) then transmits only chosen product ions to the detector, usually an electron multiplier. Operating Q1 and Q3 at fixed masses gives multiple reaction monitoring (MRM), which filters out most chemical noise and gives very selective quantitation. Other scan modes include product-ion scan, precursor-ion scan and neutral-loss scan. The instrument is normally coupled to a liquid chromatograph through an electrospray or APCI source, or to a gas chromatograph through an electron-ionization source. Ion guides, a vacuum system with turbomolecular pumps and a data system for scheduled MRM complete the design.

What are the key features?

  • Electron-ionization source at 70 eV for library-searchable, reproducible fragmentation
  • Inert or self-cleaning ion source designed to sustain response for active compounds
  • Timed MRM with hundreds of transitions for multiresidue pesticide methods
  • Heated transfer line and programmable injector for semi-volatile analyte transfer
  • Full-scan and MRM acquisition in one run for screening plus targeted quantitation
  • Support for hydrogen carrier gas with a dedicated source configuration where applicable

What are the technical specifications?

A typical triple quadrupole gc-ms/ms system configuration offers mass range of m/z 1.2–1200, ionization mode of EI (70 eV); CI optional, source temperature of 150–350 °C, transfer line temperature of up to 350 °C, minimum dwell time of ≥ 1 ms and IDL (octafluoronaphthalene, m/z 272→222) of ≤ 10 fg on column. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Triple Quadrupole GC-MS/MS System is used in multiresidue pesticide analysis, dioxin and PCB quantitation, PAH analysis in environmental samples, flavor and fragrance contaminants and forensic and doping screening. Across the wider Triple Quadrupole MS class, laboratories also deploy it for clinical and therapeutic drug monitoring, pharmacokinetic and bioanalytical studies and pesticide and veterinary drug residue testing.

Which standards and certifications apply?

Relevant standards and methods include ICH M10, FDA Bioanalytical Method Validation Guidance, EU Commission Decision 2002/657/EC, SANTE/11312/2021, ISO 17025 and CLSI C62. Certification candidates for this model are CE, IEC 61010-1 safety and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install the system in a temperature-stable room with clean, stable power and adequate floor loading for the instrument and its rotary or dry backing pumps. Supply nitrogen of sufficient purity and flow for the source and collision gas, and high-purity argon where required. Exhaust from the source and pumps must be vented safely. Perform mass calibration and tuning on a routine schedule, and run system suitability injections before each batch. Source cleaning, ion-guide maintenance and pump-oil or seal changes are the main preventive tasks. Laboratories working under regulated frameworks should plan installation, operational and performance qualification, audit-trail review and method validation according to ICH M10 or equivalent guidance.

How do I select the right Triple Quadrupole GC-MS/MS System?

Choose GC-MS/MS when target analytes are volatile or derivatizable and the matrix produces interfering background in single-quadrupole SIM. If analytes are polar, thermally labile or non-volatile, LC-MS/MS is the better route. In an RFQ specify analyte classes, required IDL and LOQ, carrier gas plan, autosampler and injector type, and expected transitions per run.

How does it compare with other Triple Quadrupole MS variants?

Start with the sample introduction technique, because it decides the source and the chromatograph: LC-MS/MS for polar, non-volatile or thermally labile analytes, GC-MS/MS for volatile and semi-volatile compounds, and ICP-MS/MS for elemental analysis. Next define the required limit of quantitation in the final matrix, not the instrument sensitivity on a neat standard, and the number of MRM transitions per run, since a fast scheduled method needs dwell times of a few milliseconds and rapid polarity switching. Consider the dynamic range needed, typically four to six orders of magnitude, and the robustness of the source and ion optics under dirty matrices. Check the vendor's regulated-data software features if the laboratory works under GLP, GMP or 21 CFR Part 11 expectations. Finally compare the total cost of ownership, including vacuum pumps, nitrogen generator demand, service and column consumption.

Full specifications

Full specifications
Mass rangem/z 1.2–1200
Ionization modeEI (70 eV); CI optional
Source temperature150–350 °C
Transfer line temperatureup to 350 °C
Minimum dwell time≥ 1 ms
IDL (octafluoronaphthalene, m/z 272→222)≤ 10 fg on column
MRM transitions per run500+ (timed)
Collision gasNitrogen with helium quench
Scan speedup to 20,000 Da/s
Carrier gas optionsHelium; hydrogen with suitable source

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Multiresidue pesticide analysis
  • Dioxin and PCB quantitation
  • PAH analysis in environmental samples
  • Flavor and fragrance contaminants
  • Forensic and doping screening

Key features

  • Electron-ionization source at 70 eV for library-searchable, reproducible fragmentation
  • Inert or self-cleaning ion source designed to sustain response for active compounds
  • Timed MRM with hundreds of transitions for multiresidue pesticide methods
  • Heated transfer line and programmable injector for semi-volatile analyte transfer
  • Full-scan and MRM acquisition in one run for screening plus targeted quantitation
  • Support for hydrogen carrier gas with a dedicated source configuration where applicable

Frequently asked questions about Triple Quadrupole GC-MS/MS System

MRM filters both the precursor and a specific fragment, so matrix ions sharing the same nominal mass are largely rejected. This lowers the baseline and improves selectivity in food, soil or biological extracts, usually giving better quantitation at low levels than single-quadrupole SIM.

Request a quotation for the Triple Quadrupole GC-MS/MS System

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote