Lab Manufacturers China

ICP-MS

电感耦合等离子体质谱仪

IMS · Mass Spectrometry Instruments · 5 models

By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <233> Elemental Impurities Procedures, ICH Q3D Elemental Impurities, EPA Method 200.8

Standards referenced

  • USP <233> Elemental Impurities Procedures
  • ICH Q3D Elemental Impurities
  • EPA Method 200.8
  • EPA Method 6020B
  • ISO 17294-2
  • ASTM D5673
  • EN 15763
  • GB 5009.268
  • ISO/IEC 17025
  • IEC 61010-1

What are ICP-MS?

ICP-MS uses an argon inductively coupled plasma to atomize and ionize a sample, then separates the ions by mass-to-charge ratio to measure elements and isotopes at parts-per-trillion levels. It is used in environmental, pharmaceutical, food, clinical, geological and semiconductor laboratories for trace metal analysis.

5 models of ICP-MS

The 5 models below are current configurations; specifications are confirmed on quotation.

Quadrupole ICP-MS with Collision/Reaction Cell

带碰撞反应池的四极杆 ICP-MS

  • IMS-0001
  • ICP-MS
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
Mass range:
m/z 2–260
Sensitivity (Y 89, standard mode):
≥ 50 Mcps/ppm
Detection limit (Pb, Cd, As in He mode):
< 1 ppt (typical)
Background (m/z 220):
< 1 cps
Oxide ratio (CeO/Ce):
≤ 1.5%
Doubly charged ratio (Ce++/Ce):
≤ 2%

A quadrupole ICP-MS with a collision or reaction cell is the standard workhorse for multi-element trace analysis. Helium kinetic energy discrimination removes most polyatomic interferences, making it suitable for routine water, food, clinical and pharmaceutical testing at ppt to ppm concentrations.

Request a quote
View details

Triple Quadrupole ICP-MS (ICP-MS/MS)

三重四极杆电感耦合等离子体质谱仪(ICP-MS/MS)

  • IMS-0002
  • ICP-MS
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
Mass range:
m/z 2–260
Sensitivity (Y 89, no-gas mode):
≥ 50 Mcps/ppm
Abundance sensitivity:
≤ 1×10^-10 (at m/z 89, Q1 + Q2)
BEC, sulfur (32S16O, O2 mode):
≤ 100 ppt
BEC, phosphorus (31P16O):
≤ 50 ppt
Oxide ratio (CeO/Ce):
≤ 1.5%

An ICP-MS/MS places two quadrupole mass filters around a reaction cell, so only the selected precursor mass enters it. This controlled reaction chemistry removes interferences that helium mode cannot, which suits sulfur, phosphorus, silicon, selenium, arsenic, rare earth elements and high-purity semiconductor analysis.

Request a quote
View details

High-Resolution Sector Field ICP-MS

高分辨扇形磁场电感耦合等离子体质谱仪

  • IMS-0003
  • ICP-MS
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
Mass range:
m/z 2–250
Resolution settings:
~300 / 4000 / 10000 (10% valley)
Sensitivity (In 115, low resolution):
≥ 1×10^9 cps/ppm
Sensitivity (In 115, high resolution):
≥ 1×10^7 cps/ppm
Detection limit (Pb, U, low resolution):
< 0.05 ppt
Background:
< 0.2 cps

A sector field ICP-MS uses a magnetic and electrostatic sector to separate analyte ions from interferences by resolving power up to 10000. It gives the lowest backgrounds and ppq-level detection limits, and is used for ultra-trace semiconductor, geochemical, nuclear and isotope ratio work.

Request a quote
View details

ICP-TOF-MS System

电感耦合等离子体飞行时间质谱仪(ICP-TOF-MS)

  • IMS-0004
  • ICP-MS
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
Mass range:
m/z 14–275 (simultaneous)
Mass resolution:
~1000–6000 FWHM
Acquisition rate:
~20–30 kHz extraction
Sensitivity (In 115):
≥ 1×10^7 cps/ppm
Detection limit (typical elements):
0.1–10 ppt
Dynamic range:
5–6 orders of magnitude

An ICP-TOF-MS records the complete elemental mass spectrum simultaneously from each plasma pulse, without scanning. It suits fast transient signals from single nanoparticles, laser ablation imaging, chromatography and other applications that need many isotopes measured together within milliseconds.

Request a quote
View details

HPLC/IC-ICP-MS Speciation System

HPLC/IC-ICP-MS 形态分析系统

  • IMS-0005
  • ICP-MS
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
LC pump pressure range:
up to 400 bar (HPLC) or 210 bar (IC)
Flow rate:
0.1–2.0 mL/min
Transfer line dead volume:
< 5 µL
Detection limit, As species:
0.01–0.05 µg/L
Detection limit, Hg species:
0.01–0.05 µg/L
Injection volume:
5–100 µL

An HPLC or ion chromatography system coupled to ICP-MS separates chemical forms of an element before detection, so species such as As(III), As(V), methylmercury, Cr(VI) and selenoamino acids are quantified individually. It is used when toxicity or bioavailability depends on the chemical form.

Request a quote
View details

Compare ICP-MS models

ModelMass rangeOxide ratio (CeO/Ce)Detector dynamic rangeArgon consumptionAbundance sensitivity
Quadrupole ICP-MS with Collision/Reaction CellIMS-0001m/z 2–260≤ 1.5%9 orders of magnitude~15–18 L/min—
Triple Quadrupole ICP-MS (ICP-MS/MS)IMS-0002m/z 2–260≤ 1.5%10 orders of magnitude~15–18 L/min≤ 1×10^-10 (at m/z 89, Q1 + Q2)
High-Resolution Sector Field ICP-MSIMS-0003m/z 2–250—~9 orders of magnitude~16–18 L/min< 1×10^-6 (at low resolution)
ICP-TOF-MS SystemIMS-0004m/z 14–275 (simultaneous)——~15–18 L/min—
HPLC/IC-ICP-MS Speciation SystemIMS-0005—————

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do ICP-MS work?

In ICP-MS, a liquid sample is nebulized into a fine aerosol, passes through a spray chamber, and is carried by argon into a plasma torch. A radio-frequency coil at 27 or 40 MHz sustains a plasma at about 6000 to 10000 K, which desolvates, atomizes and ionizes the analytes, mostly as singly charged ions. Ions are extracted through sampler and skimmer cones into a high-vacuum region, focused by ion lenses, and separated by a mass analyzer, most commonly a quadrupole. A collision or reaction cell removes polyatomic interferences such as 40Ar16O on 56Fe, using helium kinetic energy discrimination or reactive gases. An electron multiplier in pulse and analog modes counts ions across up to nine orders of magnitude.

Which ICP-MS variants are available?

  • Quadrupole ICP-MS with Collision/Reaction Cell — A quadrupole ICP-MS with a collision or reaction cell is the standard workhorse for multi-element trace analysis.
  • Triple Quadrupole ICP-MS (ICP-MS/MS) — An ICP-MS/MS places two quadrupole mass filters around a reaction cell, so only the selected precursor mass enters it.
  • High-Resolution Sector Field ICP-MS — A sector field ICP-MS uses a magnetic and electrostatic sector to separate analyte ions from interferences by resolving power up to 10000.
  • ICP-TOF-MS System — An ICP-TOF-MS records the complete elemental mass spectrum simultaneously from each plasma pulse, without scanning.
  • HPLC/IC-ICP-MS Speciation System — An HPLC or ion chromatography system coupled to ICP-MS separates chemical forms of an element before detection, so species such as As(III), As(V), methylmercury, Cr(VI) and selenoamino acids are quantified individually.

How do I choose the right variant?

Choose the ICP-MS class by interference severity, detection limit and budget. A single quadrupole with a collision cell handles most water, food and clinical work at low cost. Triple quadrupole ICP-MS/MS adds mass-shift reaction chemistry for difficult interferences such as sulfur, phosphorus, arsenic in chloride and rare earth oxides. Sector-field instruments offer high resolution and the lowest background for semiconductor and geochemical work, and TOF systems capture the full mass spectrum for fast transient signals. Check matrix tolerance, for example total dissolved solids up to 0.2 percent or aerosol dilution options for higher levels, argon consumption, sample introduction kits, autosampler and software compliance features. Verify the detection limits and background equivalent concentrations in your own matrix rather than relying on deionized water values.

Where are ICP-MS used?

ICP-MS are specified in heavy metals in drinking water and wastewater, elemental impurities in pharmaceuticals, toxic elements in food and beverages, trace metals in semiconductor-grade chemicals, geochemical and isotope ratio analysis and clinical trace element measurements in blood and urine.

Which standards and certifications apply?

Work with ICP-MS is commonly governed by USP <233> Elemental Impurities Procedures, ICH Q3D Elemental Impurities, EPA Method 200.8, EPA Method 6020B, ISO 17294-2, ASTM D5673, EN 15763, GB 5009.268, ISO/IEC 17025 and IEC 61010-1. Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

ICP-MS requires high-purity argon, typically 99.996 percent or better, with consumption around 15 to 20 L per minute, plus cooling water or a recirculating chiller, dedicated exhaust ventilation and stable power. Use trace-metal-grade acids, low-blank labware such as PFA or FEP, and ultrapure water at 18.2 MΩ·cm. Tune daily for sensitivity, oxide ratio (CeO/Ce below 2 percent) and doubly charged ratio (Ce++/Ce below 3 percent). Clean or replace cones, torch and nebulizer according to matrix load, and check the peristaltic pump tubing regularly. Use internal standards to correct drift. For pharmaceutical and regulated work, require software with audit trails and follow USP <233> and ICH Q3D method validation.

Frequently asked questions about ICP-MS

ICP-MS typically reaches low parts-per-trillion (ng/L) detection limits for most elements in clean aqueous solutions, and sub-ppt for some heavy elements. Real-world limits are higher because of sample dilution, blank contamination and matrix effects, so they must be established by method validation.

Need help specifying ICP-MS?