What are LC-MS?

LC-MS couples a liquid chromatograph to a mass spectrometer, separating compounds in solution and detecting them by mass-to-charge ratio after atmospheric-pressure ionization. It analyzes polar, non-volatile and thermally labile molecules and is used in pharmaceutical, bioanalytical, clinical, food safety and environmental laboratories.

5 models of LC-MS

The 5 models below are current configurations; specifications are confirmed on quotation.

Single Quadrupole LC-MS System

单四极杆液质联用仪

  • LCM-0001
  • LC-MS
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
Mass range:
m/z 50–2000
Mass resolution:
Unit (0.7 u FWHM)
Scan speed:
up to 5000 Da/s
Polarity switching time:
≤ 25 ms
Ion sources:
ESI, APCI (APPI optional)
Sensitivity (reserpine, 1 pg on column, ESI+ SIM):
S/N ≥ 100:1 (typical)

A single quadrupole LC-MS adds a compact mass detector to an HPLC or UHPLC, confirming molecular weight and supporting routine quantitation. It is the economical option for synthetic chemistry, peak tracking, purity confirmation and methods where unit-resolution selectivity is sufficient.

Request a quote
View details

LC-Triple Quadrupole MS/MS System

液相色谱三重四极杆串联质谱仪(LC-MS/MS)

  • LCM-0002
  • LC-MS
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
Mass range:
m/z 5–2000
Scan speed:
up to 20000 Da/s
Minimum MRM dwell time:
1–2 ms
Polarity switching time:
≤ 20 ms
Sensitivity (reserpine, 1 pg on column, ESI+ MRM 609>195):
S/N ≥ 10000:1 (typical, RMS)
Mass resolution:
Adjustable 0.4–2.0 u FWHM

An LC-MS/MS triple quadrupole system uses multiple reaction monitoring to quantify known target compounds at picogram-per-milliliter levels in complex biological and environmental matrices. It is the standard platform for regulated, high-throughput bioanalysis, clinical assays, PFAS, pesticide and veterinary drug residue testing.

Request a quote
View details

LC-Q-TOF High-Resolution MS System

液相色谱四极杆飞行时间高分辨质谱仪(LC-Q-TOF)

  • LCM-0003
  • LC-MS
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
Mass range:
m/z 50–20000 (MS mode)
Mass resolution:
30000–60000 FWHM (m/z 922)
Mass accuracy:
< 2 ppm RMS (internal calibration)
Acquisition rate:
up to 100 spectra/s
In-spectrum dynamic range:
~10^4–10^5
Sensitivity (reserpine, 1 pg on column, ESI+ MS):
S/N ≥ 1000:1 (typical)

An LC-Q-TOF combines a quadrupole precursor filter with a time-of-flight analyzer to deliver accurate-mass MS and MS/MS spectra. It is used for identifying unknowns, impurities and metabolites, non-targeted screening and retrospective data mining where quantitation and identification must share one platform.

Request a quote
View details

LC-Ion Trap MS System

液相色谱离子阱质谱仪(LC-Ion Trap MS)

  • LCM-0004
  • LC-MS
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
Mass range:
m/z 50–2000 (extendable to 4000)
Mass resolution:
Unit; up to ~20000 in ultra-zoom
MS^n capability:
MS^2 to MS^10
Scan speed:
up to 33000 Da/s (normal scan)
Mass accuracy:
±0.1 u (±0.2 u in MS^n)
Sensitivity (reserpine, 1 pg on column, full scan):
S/N ≥ 500:1 (typical)

An LC-ion trap MS stores ions in an electrodynamic trap and fragments them repeatedly, providing MSn spectra for structural elucidation. It is selected for metabolite, natural product and peptide characterization where multi-stage fragmentation matters more than high-throughput targeted quantitation.

Request a quote
View details

Mass-Directed Purification LC-MS System

质量导向纯化液质联用系统

  • LCM-0005
  • LC-MS
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
Preparative flow rate:
5–100 mL/min
Maximum pressure:
400 bar (6000 psi)
Gradient accuracy:
±1%
MS mass range:
m/z 50–2000
MS resolution:
Unit (0.7 u FWHM)
Split ratio to MS:
~1:1000 to 1:10000 (adjustable)

A mass-directed purification LC-MS uses a preparative or semi-preparative LC, a flow splitter, a single quadrupole detector and a fraction collector triggered by target mass. It isolates synthetic compounds, natural products and impurities from mixtures in milligram to gram quantities without relying on UV alone.

Request a quote
View details

Compare LC-MS models

ModelMass rangeMass resolutionScan speedPolarity switching timeIon sources
Single Quadrupole LC-MS SystemLCM-0001m/z 50–2000Unit (0.7 u FWHM)up to 5000 Da/s≤ 25 msESI, APCI (APPI optional)
LC-Triple Quadrupole MS/MS SystemLCM-0002m/z 5–2000Adjustable 0.4–2.0 u FWHMup to 20000 Da/s≤ 20 msHeated ESI, APCI (optional)
LC-Q-TOF High-Resolution MS SystemLCM-0003m/z 50–20000 (MS mode)30000–60000 FWHM (m/z 922)——ESI, APCI, dual-spray reference
LC-Ion Trap MS SystemLCM-0004m/z 50–2000 (extendable to 4000)Unit; up to ~20000 in ultra-zoomup to 33000 Da/s (normal scan)—ESI, APCI (nanospray optional)
Mass-Directed Purification LC-MS SystemLCM-0005—————

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do LC-MS work?

In LC-MS, a high-pressure pump delivers a mobile phase through a column, typically C18, where analytes separate by their affinity for the stationary phase. The eluent, usually at 0.2 to 1 mL per minute, enters an atmospheric-pressure ion source. Electrospray ionization applies 3 to 5 kV to a nebulized stream so that charged droplets shrink and release gas-phase ions, while atmospheric-pressure chemical ionization uses a corona discharge for less polar compounds. Ions pass through a skimmer or capillary and ion guides into progressively lower-pressure regions, then into the mass analyzer. Quadrupole, ion trap, time-of-flight or hybrid analyzers then measure m/z. Mobile phases must be volatile, such as formic acid, acetic acid or ammonium formate, because non-volatile buffers foul the source.

Which LC-MS variants are available?

  • Single Quadrupole LC-MS System — A single quadrupole LC-MS adds a compact mass detector to an HPLC or UHPLC, confirming molecular weight and supporting routine quantitation.
  • LC-Triple Quadrupole MS/MS System — An LC-MS/MS triple quadrupole system uses multiple reaction monitoring to quantify known target compounds at picogram-per-milliliter levels in complex biological and environmental matrices.
  • LC-Q-TOF High-Resolution MS System — An LC-Q-TOF combines a quadrupole precursor filter with a time-of-flight analyzer to deliver accurate-mass MS and MS/MS spectra.
  • LC-Ion Trap MS System — An LC-ion trap MS stores ions in an electrodynamic trap and fragments them repeatedly, providing MSn spectra for structural elucidation.
  • Mass-Directed Purification LC-MS System — A mass-directed purification LC-MS uses a preparative or semi-preparative LC, a flow splitter, a single quadrupole detector and a fraction collector triggered by target mass.

How do I choose the right variant?

The decisive choice is the mass analyzer. Single quadrupole LC-MS confirms molecular weight and performs simple quantitation at a modest cost. Triple quadrupole instruments deliver the best sensitivity for targeted quantitation in bioanalysis, residues and clinical assays. Q-TOF systems provide accurate mass and MS/MS of unknowns, suited to impurity profiling, metabolite identification and screening. Ion traps offer multi-stage fragmentation for structural work. Mass-directed purification systems add fraction collection. Then check the ion source options such as ESI, APCI and APPI, scan speed for UHPLC peaks below 3 seconds wide, polarity switching speed, and the robustness of the source with dirty matrices. Confirm compatibility with your LC pumps, available software for regulated work, and nitrogen consumption for sheath and drying gases.

Where are LC-MS used?

LC-MS are specified in drug impurity profiling and metabolite identification, bioanalysis of drugs in plasma and urine, pesticide and veterinary drug residue testing, PFAS analysis in water and food, clinical steroid and vitamin D assays and peptide and protein characterization.

Which standards and certifications apply?

Work with LC-MS is commonly governed by EPA Method 1633, EPA Method 537.1, EPA Method 533, USP <621> Chromatography, FDA Bioanalytical Method Validation Guidance, ICH M10 Bioanalytical Method Validation, EN 15662, CLSI C62-A, ISO/IEC 17025 and IEC 61010-1. Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

Provide a nitrogen supply of at least 99.5 percent purity, either from a generator delivering about 20 to 35 L per minute or from liquid supply, plus a fume extraction line for source exhaust. Use LC-MS grade solvents and additives, since impurities raise background and suppress ionization. Calibrate the mass scale regularly with the manufacturer's calibrant solution, and run system suitability injections before each batch. Clean the spray shield, capillary and ion transfer optics when sensitivity drops, and replace rotary pump oil on schedule. Monitor for ion suppression through post-column infusion during method development. Regulated laboratories need software with audit trails and electronic signatures compatible with 21 CFR Part 11, and instrument qualification to IQ, OQ and PQ protocols.

Frequently asked questions about LC-MS

Electrospray ionization is the most common and suits polar and ionizable compounds from small molecules to proteins. APCI suits less polar, thermally stable analytes below about 1500 Da. APPI handles nonpolar compounds such as PAHs. Many sources allow switching or dual-mode operation.