Skip to main content
Lab Manufacturers China
LC-Triple Quadrupole MS/MS System — product photo

LC-Triple Quadrupole MS/MS System

液相色谱三重四极杆串联质谱仪(LC-MS/MS)

  • SKU LCM-0002
  • LC-MS
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Mass rangem/z 5–2000
Scan speedup to 20000 Da/s
Minimum MRM dwell time1–2 ms
Polarity switching time≤ 20 ms
Sensitivity (reserpine, 1 pg on column, ESI+ MRM 609>195)S/N ≥ 10000:1 (typical, RMS)
Mass resolutionAdjustable 0.4–2.0 u FWHM
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: EPA Method 1633, EPA Method 537.1, EPA Method 533

What is the LC-Triple Quadrupole MS/MS System?

An LC-MS/MS triple quadrupole system uses multiple reaction monitoring to quantify known target compounds at picogram-per-milliliter levels in complex biological and environmental matrices. It is the standard platform for regulated, high-throughput bioanalysis, clinical assays, PFAS, pesticide and veterinary drug residue testing.

What is the LC-Triple Quadrupole MS/MS System?

An LC-MS/MS triple quadrupole system uses multiple reaction monitoring to quantify known target compounds at picogram-per-milliliter levels in complex biological and environmental matrices. It is the standard platform for regulated, high-throughput bioanalysis, clinical assays, PFAS, pesticide and veterinary drug residue testing.

Overview

The LC-MS/MS triple quadrupole has a first quadrupole (Q1) that selects a precursor ion, a collision cell (q2) that fragments it with argon or nitrogen, and a third quadrupole (Q3) that transmits a characteristic product ion. The MRM transition gives high selectivity even when matrix components co-elute. Modern instruments achieve dwell times near 1 to 3 ms, polarity switching in under 20 ms, and scheduled MRM with more than 500 transitions per run. A heated ESI source with nebulizer and drying gas handles flows from 0.1 to 1 mL per minute. Sensitivity is commonly described by reserpine or another standard injected on column, with typical limits of quantitation in the low pg/mL range for small molecules in plasma. Linear dynamic range of four to five orders of magnitude supports regulated quantitation, but the system provides only unit-resolution data.

How does it work?

In LC-MS, a high-pressure pump delivers a mobile phase through a column, typically C18, where analytes separate by their affinity for the stationary phase. The eluent, usually at 0.2 to 1 mL per minute, enters an atmospheric-pressure ion source. Electrospray ionization applies 3 to 5 kV to a nebulized stream so that charged droplets shrink and release gas-phase ions, while atmospheric-pressure chemical ionization uses a corona discharge for less polar compounds. Ions pass through a skimmer or capillary and ion guides into progressively lower-pressure regions, then into the mass analyzer. Quadrupole, ion trap, time-of-flight or hybrid analyzers then measure m/z. Mobile phases must be volatile, such as formic acid, acetic acid or ammonium formate, because non-volatile buffers foul the source.

What are the key features?

  • Scheduled MRM supporting 500 or more transitions with dwell times as short as 1 ms
  • Polarity switching in under 20 ms for mixed positive and negative panels
  • Heated ESI source with high-flow capability and resistance to matrix contamination
  • Collision cell with fast fragmentation and low crosstalk at high scan rates
  • Regulated-lab software with audit trail, e-signatures and batch-level acceptance criteria
  • Optional APCI source and ion mobility-free design for robust routine operation

What are the technical specifications?

A typical lc-triple quadrupole ms/ms system configuration offers mass range of m/z 5–2000, scan speed of up to 20000 Da/s, minimum MRM dwell time of 1–2 ms, polarity switching time of ≤ 20 ms, sensitivity (reserpine, 1 pg on column, ESI+ MRM 609>195) of S/N ≥ 10000:1 (typical, RMS) and mass resolution of Adjustable 0.4–2.0 u FWHM. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The LC-Triple Quadrupole MS/MS System is used in regulated bioanalysis of drugs and metabolites, clinical steroid, vitamin D and immunosuppressant assays, PFAS quantitation in water and food, multi-residue pesticide and veterinary drug screening and mycotoxin and toxin analysis. Across the wider LC-MS class, laboratories also deploy it for drug impurity profiling and metabolite identification, bioanalysis of drugs in plasma and urine and pesticide and veterinary drug residue testing.

Which standards and certifications apply?

Relevant standards and methods include EPA Method 1633, EPA Method 537.1, EPA Method 533, USP <621> Chromatography, FDA Bioanalytical Method Validation Guidance, ICH M10 Bioanalytical Method Validation, EN 15662, CLSI C62-A, ISO/IEC 17025 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Provide a nitrogen supply of at least 99.5 percent purity, either from a generator delivering about 20 to 35 L per minute or from liquid supply, plus a fume extraction line for source exhaust. Use LC-MS grade solvents and additives, since impurities raise background and suppress ionization. Calibrate the mass scale regularly with the manufacturer's calibrant solution, and run system suitability injections before each batch. Clean the spray shield, capillary and ion transfer optics when sensitivity drops, and replace rotary pump oil on schedule. Monitor for ion suppression through post-column infusion during method development. Regulated laboratories need software with audit trails and electronic signatures compatible with 21 CFR Part 11, and instrument qualification to IQ, OQ and PQ protocols.

How do I select the right LC-Triple Quadrupole MS/MS System?

Select LC-MS/MS triple quadrupole for targeted quantitation requiring low limits of quantitation, wide linear range and compliance with bioanalytical or environmental methods. Choose Q-TOF for unknown identification. In an RFQ, specify MRM capacity, dwell time, reserpine sensitivity, source type, collision gas, software compliance features and throughput with your UHPLC.

How does it compare with other LC-MS variants?

The decisive choice is the mass analyzer. Single quadrupole LC-MS confirms molecular weight and performs simple quantitation at a modest cost. Triple quadrupole instruments deliver the best sensitivity for targeted quantitation in bioanalysis, residues and clinical assays. Q-TOF systems provide accurate mass and MS/MS of unknowns, suited to impurity profiling, metabolite identification and screening. Ion traps offer multi-stage fragmentation for structural work. Mass-directed purification systems add fraction collection. Then check the ion source options such as ESI, APCI and APPI, scan speed for UHPLC peaks below 3 seconds wide, polarity switching speed, and the robustness of the source with dirty matrices. Confirm compatibility with your LC pumps, available software for regulated work, and nitrogen consumption for sheath and drying gases.

Full specifications

Full specifications
Mass rangem/z 5–2000
Scan speedup to 20000 Da/s
Minimum MRM dwell time1–2 ms
Polarity switching time≤ 20 ms
Sensitivity (reserpine, 1 pg on column, ESI+ MRM 609>195)S/N ≥ 10000:1 (typical, RMS)
Mass resolutionAdjustable 0.4–2.0 u FWHM
Linear dynamic range≥ 10^5
Collision gasArgon (nitrogen optional), 99.999%
Ion sourcesHeated ESI, APCI (optional)
Flow rate compatibility0.05–2.0 mL/min

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Regulated bioanalysis of drugs and metabolites
  • Clinical steroid, vitamin D and immunosuppressant assays
  • PFAS quantitation in water and food
  • Multi-residue pesticide and veterinary drug screening
  • Mycotoxin and toxin analysis

Key features

  • Scheduled MRM supporting 500 or more transitions with dwell times as short as 1 ms
  • Polarity switching in under 20 ms for mixed positive and negative panels
  • Heated ESI source with high-flow capability and resistance to matrix contamination
  • Collision cell with fast fragmentation and low crosstalk at high scan rates
  • Regulated-lab software with audit trail, e-signatures and batch-level acceptance criteria
  • Optional APCI source and ion mobility-free design for robust routine operation

Frequently asked questions about LC-Triple Quadrupole MS/MS System

Multiple reaction monitoring is a tandem MS mode in which Q1 selects a specific precursor ion, the collision cell fragments it, and Q3 monitors a chosen product ion. Only compounds producing that precursor-to-product transition are detected, which gives high selectivity and low background.

Related models

All LC-MS
LC-Ion Trap MS System — product photo

LC-Ion Trap MS System

液相色谱离子阱质谱仪(LC-Ion Trap MS)

  • CE (to be confirmed)
  • +2
Request a quote
GC-TOF MS System — product photo

GC-TOF MS System

气相色谱飞行时间质谱仪(GC-TOF MS)

  • CE (to be confirmed)
  • +2
Request a quote

Request a quotation for the LC-Triple Quadrupole MS/MS System

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote