LC-Triple Quadrupole MS/MS System
液相色谱三重四极杆串联质谱仪(LC-MS/MS)
- SKU LCM-0002
- LC-MS
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IEC 61010-1 safety (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Mass range | m/z 5–2000 |
|---|---|
| Scan speed | up to 20000 Da/s |
| Minimum MRM dwell time | 1–2 ms |
| Polarity switching time | ≤ 20 ms |
| Sensitivity (reserpine, 1 pg on column, ESI+ MRM 609>195) | S/N ≥ 10000:1 (typical, RMS) |
| Mass resolution | Adjustable 0.4–2.0 u FWHM |
By Lab Manufacturers China Technical TeamLast reviewed Standards: EPA Method 1633, EPA Method 537.1, EPA Method 533
What is the LC-Triple Quadrupole MS/MS System?
An LC-MS/MS triple quadrupole system uses multiple reaction monitoring to quantify known target compounds at picogram-per-milliliter levels in complex biological and environmental matrices. It is the standard platform for regulated, high-throughput bioanalysis, clinical assays, PFAS, pesticide and veterinary drug residue testing.
What is the LC-Triple Quadrupole MS/MS System?
An LC-MS/MS triple quadrupole system uses multiple reaction monitoring to quantify known target compounds at picogram-per-milliliter levels in complex biological and environmental matrices. It is the standard platform for regulated, high-throughput bioanalysis, clinical assays, PFAS, pesticide and veterinary drug residue testing.
Overview
The LC-MS/MS triple quadrupole has a first quadrupole (Q1) that selects a precursor ion, a collision cell (q2) that fragments it with argon or nitrogen, and a third quadrupole (Q3) that transmits a characteristic product ion. The MRM transition gives high selectivity even when matrix components co-elute. Modern instruments achieve dwell times near 1 to 3 ms, polarity switching in under 20 ms, and scheduled MRM with more than 500 transitions per run. A heated ESI source with nebulizer and drying gas handles flows from 0.1 to 1 mL per minute. Sensitivity is commonly described by reserpine or another standard injected on column, with typical limits of quantitation in the low pg/mL range for small molecules in plasma. Linear dynamic range of four to five orders of magnitude supports regulated quantitation, but the system provides only unit-resolution data.
How does it work?
In LC-MS, a high-pressure pump delivers a mobile phase through a column, typically C18, where analytes separate by their affinity for the stationary phase. The eluent, usually at 0.2 to 1 mL per minute, enters an atmospheric-pressure ion source. Electrospray ionization applies 3 to 5 kV to a nebulized stream so that charged droplets shrink and release gas-phase ions, while atmospheric-pressure chemical ionization uses a corona discharge for less polar compounds. Ions pass through a skimmer or capillary and ion guides into progressively lower-pressure regions, then into the mass analyzer. Quadrupole, ion trap, time-of-flight or hybrid analyzers then measure m/z. Mobile phases must be volatile, such as formic acid, acetic acid or ammonium formate, because non-volatile buffers foul the source.
What are the key features?
- Scheduled MRM supporting 500 or more transitions with dwell times as short as 1 ms
- Polarity switching in under 20 ms for mixed positive and negative panels
- Heated ESI source with high-flow capability and resistance to matrix contamination
- Collision cell with fast fragmentation and low crosstalk at high scan rates
- Regulated-lab software with audit trail, e-signatures and batch-level acceptance criteria
- Optional APCI source and ion mobility-free design for robust routine operation
What are the technical specifications?
A typical lc-triple quadrupole ms/ms system configuration offers mass range of m/z 5–2000, scan speed of up to 20000 Da/s, minimum MRM dwell time of 1–2 ms, polarity switching time of ≤ 20 ms, sensitivity (reserpine, 1 pg on column, ESI+ MRM 609>195) of S/N ≥ 10000:1 (typical, RMS) and mass resolution of Adjustable 0.4–2.0 u FWHM. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The LC-Triple Quadrupole MS/MS System is used in regulated bioanalysis of drugs and metabolites, clinical steroid, vitamin D and immunosuppressant assays, PFAS quantitation in water and food, multi-residue pesticide and veterinary drug screening and mycotoxin and toxin analysis. Across the wider LC-MS class, laboratories also deploy it for drug impurity profiling and metabolite identification, bioanalysis of drugs in plasma and urine and pesticide and veterinary drug residue testing.
Which standards and certifications apply?
Relevant standards and methods include EPA Method 1633, EPA Method 537.1, EPA Method 533, USP <621> Chromatography, FDA Bioanalytical Method Validation Guidance, ICH M10 Bioanalytical Method Validation, EN 15662, CLSI C62-A, ISO/IEC 17025 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Provide a nitrogen supply of at least 99.5 percent purity, either from a generator delivering about 20 to 35 L per minute or from liquid supply, plus a fume extraction line for source exhaust. Use LC-MS grade solvents and additives, since impurities raise background and suppress ionization. Calibrate the mass scale regularly with the manufacturer's calibrant solution, and run system suitability injections before each batch. Clean the spray shield, capillary and ion transfer optics when sensitivity drops, and replace rotary pump oil on schedule. Monitor for ion suppression through post-column infusion during method development. Regulated laboratories need software with audit trails and electronic signatures compatible with 21 CFR Part 11, and instrument qualification to IQ, OQ and PQ protocols.
How do I select the right LC-Triple Quadrupole MS/MS System?
Select LC-MS/MS triple quadrupole for targeted quantitation requiring low limits of quantitation, wide linear range and compliance with bioanalytical or environmental methods. Choose Q-TOF for unknown identification. In an RFQ, specify MRM capacity, dwell time, reserpine sensitivity, source type, collision gas, software compliance features and throughput with your UHPLC.
How does it compare with other LC-MS variants?
The decisive choice is the mass analyzer. Single quadrupole LC-MS confirms molecular weight and performs simple quantitation at a modest cost. Triple quadrupole instruments deliver the best sensitivity for targeted quantitation in bioanalysis, residues and clinical assays. Q-TOF systems provide accurate mass and MS/MS of unknowns, suited to impurity profiling, metabolite identification and screening. Ion traps offer multi-stage fragmentation for structural work. Mass-directed purification systems add fraction collection. Then check the ion source options such as ESI, APCI and APPI, scan speed for UHPLC peaks below 3 seconds wide, polarity switching speed, and the robustness of the source with dirty matrices. Confirm compatibility with your LC pumps, available software for regulated work, and nitrogen consumption for sheath and drying gases.
Full specifications
| Mass range | m/z 5–2000 |
|---|---|
| Scan speed | up to 20000 Da/s |
| Minimum MRM dwell time | 1–2 ms |
| Polarity switching time | ≤ 20 ms |
| Sensitivity (reserpine, 1 pg on column, ESI+ MRM 609>195) | S/N ≥ 10000:1 (typical, RMS) |
| Mass resolution | Adjustable 0.4–2.0 u FWHM |
| Linear dynamic range | ≥ 10^5 |
| Collision gas | Argon (nitrogen optional), 99.999% |
| Ion sources | Heated ESI, APCI (optional) |
| Flow rate compatibility | 0.05–2.0 mL/min |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Regulated bioanalysis of drugs and metabolites
- Clinical steroid, vitamin D and immunosuppressant assays
- PFAS quantitation in water and food
- Multi-residue pesticide and veterinary drug screening
- Mycotoxin and toxin analysis
Key features
- Scheduled MRM supporting 500 or more transitions with dwell times as short as 1 ms
- Polarity switching in under 20 ms for mixed positive and negative panels
- Heated ESI source with high-flow capability and resistance to matrix contamination
- Collision cell with fast fragmentation and low crosstalk at high scan rates
- Regulated-lab software with audit trail, e-signatures and batch-level acceptance criteria
- Optional APCI source and ion mobility-free design for robust routine operation
Frequently asked questions about LC-Triple Quadrupole MS/MS System
Multiple reaction monitoring is a tandem MS mode in which Q1 selects a specific precursor ion, the collision cell fragments it, and Q3 monitors a chosen product ion. Only compounds producing that precursor-to-product transition are detected, which gives high selectivity and low background.
Two transitions per compound are standard for confirmatory work: a quantifier for measurement and a qualifier whose ion ratio to the quantifier confirms identity. Guidelines such as those for residue analysis set ion ratio tolerances, often within 20 to 30 percent relative.
Limits depend on the analyte, matrix and sample preparation. Small molecules in plasma commonly reach 0.05 to 1 ng/mL, and PFAS in water can reach low ng/L with solid-phase extraction. Values must be established experimentally through method validation, not assumed from the specifications.
Electrospray ionization is the most common and suits polar and ionizable compounds from small molecules to proteins. APCI suits less polar, thermally stable analytes below about 1500 Da. APPI handles nonpolar compounds such as PAHs. Many sources allow switching or dual-mode operation.
Ion suppression is a reduction in analyte signal caused by co-eluting matrix components that compete for charge or disrupt droplet formation. It affects accuracy and sensitivity. It is managed with better sample cleanup, chromatographic separation, dilution and isotopically labeled internal standards.
Use volatile additives such as formic acid, acetic acid, ammonium formate, ammonium acetate and ammonium hydroxide, generally at 0.1 percent or 2 to 10 mM. Avoid non-volatile phosphate, borate and high concentrations of ion-pairing reagents, which contaminate the source and suppress ionization.