What are Dissolution Systems?

Dissolution systems measure how quickly a drug is released from a solid dosage form into a thermostatted medium, using the standard USP or pharmacopoeial apparatus. Pharmaceutical quality control and development laboratories use them for release testing, profile comparison and bioequivalence support.

5 models of Dissolution Systems

The 5 models below are current configurations; specifications are confirmed on quotation.

USP Apparatus 1 Basket Dissolution System

USP 装置 1 篮法溶出系统

  • DIS-0001
  • Dissolution Systems
  • CE (to be confirmed)
  • IEC 61010-1 compliance (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
Apparatus type:
USP Apparatus 1 basket
Vessel volume:
500–1000 mL
Temperature:
37 ±0.5 °C
Rotation speed:
50–150 rpm, ±4 percent
Basket mesh:
40 mesh typical
Vessel positions:
6 or 8

A USP Apparatus 1 system rotates the dosage form inside a wire basket immersed in a vessel of medium. It is chosen for capsules and for products that tend to float or stick to the vessel wall.

Request a quote
View details

USP Apparatus 2 Paddle Dissolution System

USP 装置 2 桨法溶出系统

  • DIS-0002
  • Dissolution Systems
  • CE (to be confirmed)
  • IEC 61010-1 compliance (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
Apparatus type:
USP Apparatus 2 paddle
Vessel volume:
500–2000 mL
Temperature:
37 ±0.5 °C
Rotation speed:
25–200 rpm, ±4 percent
Paddle height:
25 ±2 mm from vessel base
Vessel positions:
6 or 8

A USP Apparatus 2 system rotates a paddle above the dosage form in a vessel of medium, and is the most widely used dissolution method. It is chosen for immediate-release tablets and many capsules.

Request a quote
View details

USP Apparatus 3 Reciprocating Cylinder Dissolution System

USP 装置 3 往复筒溶出系统

  • DIS-0003
  • Dissolution Systems
  • CE (to be confirmed)
  • IEC 61010-1 compliance (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
Apparatus type:
USP Apparatus 3 reciprocating cylinder
Tube volume:
about 250 mL per tube
Temperature:
37 ±0.5 °C
Dip rate:
5–40 dips per minute
Stroke length:
about 20–40 mm
Screen mesh:
40 mesh typical

A USP Apparatus 3 system moves a sample in a reciprocating glass cylinder between rows of medium-filled tubes. It is chosen for modified-release dosage forms and for methods that need automatic pH changes.

Request a quote
View details

USP Apparatus 4 Flow-Through Cell Dissolution System

USP 装置 4 流通池溶出系统

  • DIS-0004
  • Dissolution Systems
  • CE (to be confirmed)
  • IEC 61010-1 compliance (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
Apparatus type:
USP Apparatus 4 flow-through cell
Cell diameter:
12 mm or 22.6 mm
Flow rate:
4–16 mL/min
Temperature:
37 ±0.5 °C
Mode:
Open or closed
Cell positions:
1–8

A USP Apparatus 4 system pumps dissolution medium continuously through a cell holding the dosage form. It is chosen for poorly soluble drugs and for products that need large medium volumes in sink conditions.

Request a quote
View details

USP Apparatus 7 Reciprocating Holder Dissolution System

USP 装置 7 往复架溶出系统

  • DIS-0005
  • Dissolution Systems
  • CE (to be confirmed)
  • IEC 61010-1 compliance (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
Apparatus type:
USP Apparatus 7 reciprocating holder
Medium volume:
10–200 mL
Temperature:
32 °C or 37 °C ±0.5 °C
Dip rate:
10–30 dips per minute
Stroke length:
about 20–30 mm
Holder options:
Patch, stent, implant, suppository

A USP Apparatus 7 system oscillates a sample holder in a small volume of medium, and is designed for transdermal patches, stents and small implants. It is chosen when conventional vessels cannot hold the dosage form.

Request a quote
View details

Compare Dissolution Systems models

ModelApparatus typeVessel volumeTemperatureRotation speedVessel positions
USP Apparatus 1 Basket Dissolution SystemDIS-0001USP Apparatus 1 basket500–1000 mL37 ±0.5 °C50–150 rpm, ±4 percent6 or 8
USP Apparatus 2 Paddle Dissolution SystemDIS-0002USP Apparatus 2 paddle500–2000 mL37 ±0.5 °C25–200 rpm, ±4 percent6 or 8
USP Apparatus 3 Reciprocating Cylinder Dissolution SystemDIS-0003USP Apparatus 3 reciprocating cylinder—37 ±0.5 °C——
USP Apparatus 4 Flow-Through Cell Dissolution SystemDIS-0004USP Apparatus 4 flow-through cell—37 ±0.5 °C——
USP Apparatus 7 Reciprocating Holder Dissolution SystemDIS-0005USP Apparatus 7 reciprocating holder—32 °C or 37 °C ±0.5 °C——

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do Dissolution Systems work?

A dissolution system holds a defined volume of dissolution medium at 37 °C and applies controlled agitation to a dosage form. Depending on the apparatus, a basket or paddle rotates in a vessel, a reciprocating cylinder moves the sample up and down between rows of tubes, a flow-through cell pumps medium past a fixed sample, or a holder oscillates in a small volume. Samples are withdrawn at set times by a manual syringe or an automated sampling station, filtered, and the dissolved amount is measured, usually by UV-Vis or HPLC. Results are expressed as percentage dissolved against labelled content, and a profile of several time points shows release behaviour. Temperature, agitation speed, medium composition, degassing and vessel geometry all affect the result, so equipment qualification and method control are critical.

Which Dissolution Systems variants are available?

  • USP Apparatus 1 Basket Dissolution System — A USP Apparatus 1 system rotates the dosage form inside a wire basket immersed in a vessel of medium.
  • USP Apparatus 2 Paddle Dissolution System — A USP Apparatus 2 system rotates a paddle above the dosage form in a vessel of medium, and is the most widely used dissolution method.
  • USP Apparatus 3 Reciprocating Cylinder Dissolution System — A USP Apparatus 3 system moves a sample in a reciprocating glass cylinder between rows of medium-filled tubes.
  • USP Apparatus 4 Flow-Through Cell Dissolution System — A USP Apparatus 4 system pumps dissolution medium continuously through a cell holding the dosage form.
  • USP Apparatus 7 Reciprocating Holder Dissolution System — A USP Apparatus 7 system oscillates a sample holder in a small volume of medium, and is designed for transdermal patches, stents and small implants.

How do I choose the right variant?

Choose the apparatus that the pharmacopoeial monograph or validated in-house method specifies. Paddles and baskets cover most immediate-release tablets and capsules. Reciprocating cylinders suit modified-release dosage forms and automatic media changes. Flow-through cells serve poorly soluble drugs that need large volumes and continuous fresh medium, and reciprocating holders suit transdermal systems, stents and small implants. Then decide on manual or automated sampling, and on UV-Vis or HPLC analysis of the samples. Compare vessel count, temperature control and uniformity, agitation speed accuracy, sampling precision and whether media preparation and cleaning are automated. Confirm qualification documents and software suitable for a GMP environment.

Where are Dissolution Systems used?

Dissolution Systems are specified in immediate-release tablet release testing, modified-release dosage form profiling, bioequivalence support, suspension and transdermal release testing and stability testing of solid dosage forms.

Which standards and certifications apply?

Work with Dissolution Systems is commonly governed by USP <711>, USP <724>, USP <1092>, ICH Q2(R2), IEC 61010-1 and ISO 17025. Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

Install the system on a stable, level bench away from vibration and draughts, because vibration and air movement disturb flow patterns. Verify vessel temperature at multiple positions inside each vessel, and check rotation speed with a tachometer at defined intervals. Degas medium consistently, since dissolved air changes results, and prepare media accurately with volumetric glassware or calibrated dispensers. Keep vessels clean and free of scratches, use the correct paddle or basket height, and replace worn parts. Document qualification, calibration and every run, including medium composition, degassing method and sample times, because dissolution results are highly method-dependent and subject to regulatory scrutiny.

Frequently asked questions about Dissolution Systems

The choice follows the monograph or validated method. Apparatus 1 baskets and Apparatus 2 paddles cover most immediate-release products, Apparatus 3 reciprocating cylinders suit modified-release forms, Apparatus 4 flow-through cells handle poorly soluble drugs, and Apparatus 7 holders suit transdermal and implantable devices.