USP Apparatus 4 Flow-Through Cell Dissolution System

USP 装置 4 流通池溶出系统

  • SKU DIS-0004
  • Dissolution Systems
  • CE (to be confirmed)
  • IEC 61010-1 compliance (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Apparatus typeUSP Apparatus 4 flow-through cell
Cell diameter12 mm or 22.6 mm
Flow rate4–16 mL/min
Temperature37 ±0.5 °C
ModeOpen or closed
Cell positions1–8
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <711>, USP <724>, USP <1092>

What is the USP Apparatus 4 Flow-Through Cell Dissolution System?

A USP Apparatus 4 system pumps dissolution medium continuously through a cell holding the dosage form. It is chosen for poorly soluble drugs and for products that need large medium volumes in sink conditions.

What is the USP Apparatus 4 Flow-Through Cell Dissolution System?

A USP Apparatus 4 system pumps dissolution medium continuously through a cell holding the dosage form. It is chosen for poorly soluble drugs and for products that need large medium volumes in sink conditions.

Overview

Apparatus 4 places the dosage form in a small cell, often with glass beads or a bed to disperse the sample, and pumps pre-warmed medium through the cell at a controlled flow rate. Because fresh medium is continuously supplied, the drug concentration remains low, so sink conditions are maintained even for poorly soluble compounds that would need thousands of millilitres in a vessel. Cells come in several sizes, commonly 12 mm and 22.6 mm internal diameter, and can be used in open mode, where medium passes through once, or closed mode, where a fixed volume is recirculated. Flow rate is typically 4 to 16 mL per minute, and temperature must be held at 37 °C. The technique suits powders, granules, implants and poorly soluble drugs, and results depend strongly on cell geometry, flow rate and the sample bed.

How does it work?

A dissolution system holds a defined volume of dissolution medium at 37 °C and applies controlled agitation to a dosage form. Depending on the apparatus, a basket or paddle rotates in a vessel, a reciprocating cylinder moves the sample up and down between rows of tubes, a flow-through cell pumps medium past a fixed sample, or a holder oscillates in a small volume. Samples are withdrawn at set times by a manual syringe or an automated sampling station, filtered, and the dissolved amount is measured, usually by UV-Vis or HPLC. Results are expressed as percentage dissolved against labelled content, and a profile of several time points shows release behaviour. Temperature, agitation speed, medium composition, degassing and vessel geometry all affect the result, so equipment qualification and method control are critical.

What are the key features?

  • Continuous medium flow through a small cell
  • Open or closed circulation mode
  • Sink conditions for poorly soluble drugs
  • Interchangeable cell diameters
  • Flow rate programmable from about 4–16 mL/min
  • Suited to powders, granules and implants

What are the technical specifications?

A typical usp apparatus 4 flow-through cell dissolution system configuration offers apparatus type of USP Apparatus 4 flow-through cell, cell diameter of 12 mm or 22.6 mm, flow rate of 4–16 mL/min, temperature of 37 ±0.5 °C, mode of Open or closed and cell positions of 1–8. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The USP Apparatus 4 Flow-Through Cell Dissolution System is used in poorly soluble drug testing, powder and granule release testing, implant and stent release and sink condition methods. Across the wider Dissolution Systems class, laboratories also deploy it for immediate-release tablet release testing, modified-release dosage form profiling and bioequivalence support.

Which standards and certifications apply?

Relevant standards and methods include USP <711>, USP <724>, USP <1092>, ICH Q2(R2), IEC 61010-1 and ISO 17025. Certification candidates for this model are CE, IEC 61010-1 compliance and ISO 13485 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install the system on a stable, level bench away from vibration and draughts, because vibration and air movement disturb flow patterns. Verify vessel temperature at multiple positions inside each vessel, and check rotation speed with a tachometer at defined intervals. Degas medium consistently, since dissolved air changes results, and prepare media accurately with volumetric glassware or calibrated dispensers. Keep vessels clean and free of scratches, use the correct paddle or basket height, and replace worn parts. Document qualification, calibration and every run, including medium composition, degassing method and sample times, because dissolution results are highly method-dependent and subject to regulatory scrutiny.

How do I select the right USP Apparatus 4 Flow-Through Cell Dissolution System?

Specify Apparatus 4 for poorly soluble compounds or when the method needs continuous fresh medium and sink conditions. Confirm cell diameters, flow rate range and control, open and closed modes and temperature stability. Define the sample bed and cell packing precisely, because they strongly influence results.

How does it compare with other Dissolution Systems variants?

Choose the apparatus that the pharmacopoeial monograph or validated in-house method specifies. Paddles and baskets cover most immediate-release tablets and capsules. Reciprocating cylinders suit modified-release dosage forms and automatic media changes. Flow-through cells serve poorly soluble drugs that need large volumes and continuous fresh medium, and reciprocating holders suit transdermal systems, stents and small implants. Then decide on manual or automated sampling, and on UV-Vis or HPLC analysis of the samples. Compare vessel count, temperature control and uniformity, agitation speed accuracy, sampling precision and whether media preparation and cleaning are automated. Confirm qualification documents and software suitable for a GMP environment.

Full specifications

Full specifications
Apparatus typeUSP Apparatus 4 flow-through cell
Cell diameter12 mm or 22.6 mm
Flow rate4–16 mL/min
Temperature37 ±0.5 °C
ModeOpen or closed
Cell positions1–8
Media volumes availableup to several litres per run
Power supply220 V, 50 Hz, about 1 kW

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Poorly soluble drug testing
  • Powder and granule release testing
  • Implant and stent release
  • Sink condition methods

Key features

  • Continuous medium flow through a small cell
  • Open or closed circulation mode
  • Sink conditions for poorly soluble drugs
  • Interchangeable cell diameters
  • Flow rate programmable from about 4–16 mL/min
  • Suited to powders, granules and implants

Frequently asked questions about USP Apparatus 4 Flow-Through Cell Dissolution System

Because fresh medium flows continuously past the sample, the concentration stays low and sink conditions are maintained without needing very large vessel volumes. This makes it practical to test compounds that would otherwise require thousands of millilitres.