USP Apparatus 1 Basket Dissolution System
USP 装置 1 篮法溶出系统
- SKU DIS-0001
- Dissolution Systems
- CE (to be confirmed)
- IEC 61010-1 compliance (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Apparatus type | USP Apparatus 1 basket |
|---|---|
| Vessel volume | 500–1000 mL |
| Temperature | 37 ±0.5 °C |
| Rotation speed | 50–150 rpm, ±4 percent |
| Basket mesh | 40 mesh typical |
| Vessel positions | 6 or 8 |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <711>, USP <724>, USP <1092>
What is the USP Apparatus 1 Basket Dissolution System?
A USP Apparatus 1 system rotates the dosage form inside a wire basket immersed in a vessel of medium. It is chosen for capsules and for products that tend to float or stick to the vessel wall.
What is the USP Apparatus 1 Basket Dissolution System?
A USP Apparatus 1 system rotates the dosage form inside a wire basket immersed in a vessel of medium. It is chosen for capsules and for products that tend to float or stick to the vessel wall.
Overview
Apparatus 1 uses a cylindrical basket of defined mesh, usually 40 mesh, attached to a rotating shaft and immersed in the dissolution vessel. The dosage form sits in the basket, so capsules and formulations that float or adhere to the vessel bottom are held in a controlled position where the medium flow is reproducible. Rotation speeds typically range from 50 to 150 rpm, with 100 rpm common for capsules. Basket mesh size, wire thickness and cleanliness affect results, and damaged or clogged baskets cause variability. Apparatus 1 is often preferred for capsules and for products with a tendency to float, but the basket can retain undissolved excipient and is harder to clean than a paddle. Comparison between basket and paddle results requires care because hydrodynamics differ.
How does it work?
A dissolution system holds a defined volume of dissolution medium at 37 °C and applies controlled agitation to a dosage form. Depending on the apparatus, a basket or paddle rotates in a vessel, a reciprocating cylinder moves the sample up and down between rows of tubes, a flow-through cell pumps medium past a fixed sample, or a holder oscillates in a small volume. Samples are withdrawn at set times by a manual syringe or an automated sampling station, filtered, and the dissolved amount is measured, usually by UV-Vis or HPLC. Results are expressed as percentage dissolved against labelled content, and a profile of several time points shows release behaviour. Temperature, agitation speed, medium composition, degassing and vessel geometry all affect the result, so equipment qualification and method control are critical.
What are the key features?
- Rotating cylindrical basket of defined mesh
- Holds floating or wall-adhering dosage forms
- Rotation speed typically 50–150 rpm
- Six or eight vessel configurations available
- Compatible with automated sampling
- Suitable for capsule release testing
What are the technical specifications?
A typical usp apparatus 1 basket dissolution system configuration offers apparatus type of USP Apparatus 1 basket, vessel volume of 500–1000 mL, temperature of 37 ±0.5 °C, rotation speed of 50–150 rpm, ±4 percent, basket mesh of 40 mesh typical and vessel positions of 6 or 8. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The USP Apparatus 1 Basket Dissolution System is used in capsule dissolution testing, floating dosage forms, immediate-release tablets and pharmacopoeial release testing. Across the wider Dissolution Systems class, laboratories also deploy it for immediate-release tablet release testing, modified-release dosage form profiling and bioequivalence support.
Which standards and certifications apply?
Relevant standards and methods include USP <711>, USP <724>, USP <1092>, ICH Q2(R2), IEC 61010-1 and ISO 17025. Certification candidates for this model are CE, IEC 61010-1 compliance and ISO 13485 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the system on a stable, level bench away from vibration and draughts, because vibration and air movement disturb flow patterns. Verify vessel temperature at multiple positions inside each vessel, and check rotation speed with a tachometer at defined intervals. Degas medium consistently, since dissolved air changes results, and prepare media accurately with volumetric glassware or calibrated dispensers. Keep vessels clean and free of scratches, use the correct paddle or basket height, and replace worn parts. Document qualification, calibration and every run, including medium composition, degassing method and sample times, because dissolution results are highly method-dependent and subject to regulatory scrutiny.
How do I select the right USP Apparatus 1 Basket Dissolution System?
Specify a basket apparatus when the monograph requires it, or when capsules or floating tablets behave poorly in a paddle. Confirm basket mesh and quality, rotation speed accuracy, vessel count and sampling arrangement. Plan for basket inspection and cleaning, since clogged or bent baskets are a common source of failed results.
How does it compare with other Dissolution Systems variants?
Choose the apparatus that the pharmacopoeial monograph or validated in-house method specifies. Paddles and baskets cover most immediate-release tablets and capsules. Reciprocating cylinders suit modified-release dosage forms and automatic media changes. Flow-through cells serve poorly soluble drugs that need large volumes and continuous fresh medium, and reciprocating holders suit transdermal systems, stents and small implants. Then decide on manual or automated sampling, and on UV-Vis or HPLC analysis of the samples. Compare vessel count, temperature control and uniformity, agitation speed accuracy, sampling precision and whether media preparation and cleaning are automated. Confirm qualification documents and software suitable for a GMP environment.
Full specifications
| Apparatus type | USP Apparatus 1 basket |
|---|---|
| Vessel volume | 500–1000 mL |
| Temperature | 37 ±0.5 °C |
| Rotation speed | 50–150 rpm, ±4 percent |
| Basket mesh | 40 mesh typical |
| Vessel positions | 6 or 8 |
| Sampling | Manual or automated |
| Power supply | 220 V, 50 Hz, about 1 kW |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Capsule dissolution testing
- Floating dosage forms
- Immediate-release tablets
- Pharmacopoeial release testing
Key features
- Rotating cylindrical basket of defined mesh
- Holds floating or wall-adhering dosage forms
- Rotation speed typically 50–150 rpm
- Six or eight vessel configurations available
- Compatible with automated sampling
- Suitable for capsule release testing
Frequently asked questions about USP Apparatus 1 Basket Dissolution System
Capsules often float or soften and adhere, which changes the flow around them in a paddle vessel. The basket keeps the capsule in a fixed, defined position so the medium flow and release rate are more reproducible between vessels and runs.
Finer mesh retains more undissolved material and can restrict medium exchange, while coarser mesh allows larger particles to escape. The monograph specifies the mesh, and any deviation changes release kinetics, so baskets should match the method and be checked for damage.
Yes. Excipient residues and dried medium collect in the mesh and around the shaft, and incomplete cleaning affects the next run. Baskets are usually soaked, brushed and rinsed, and inspected under magnification for bent wires or blocked openings.
The choice follows the monograph or validated method. Apparatus 1 baskets and Apparatus 2 paddles cover most immediate-release products, Apparatus 3 reciprocating cylinders suit modified-release forms, Apparatus 4 flow-through cells handle poorly soluble drugs, and Apparatus 7 holders suit transdermal and implantable devices.
Dissolved air forms bubbles that can change hydrodynamics and interfere with detection, and it also affects the measured concentration. Medium is therefore degassed by heating, vacuum, sonication or helium sparging, and the same method must be used every time.
Sink condition means the volume of medium is at least three times that needed to dissolve the labelled amount of drug, so the drug concentration stays well below saturation. It reduces the chance that dissolution slows because the medium is becoming saturated.
Related models