Reach-In Stability Chamber

立式稳定性试验箱

  • SKU STC-0002
  • Stability Chambers
  • CE (to be confirmed)
  • IEC 61010-1 compliance (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Temperature range5–60 °C
Temperature stability±0.5 °C
Humidity range40–95 percent RH
Humidity stability±3 percent RH
Chamber volumeabout 400–1000 L
Shelves4–8 adjustable
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ICH Q1A(R2), ICH Q1B, ICH Q1C

What is the Reach-In Stability Chamber?

A reach-in stability chamber is a cabinet-sized unit that holds multiple shelves of samples at controlled temperature and humidity. It is the standard choice for routine ICH stability programmes in pharmaceutical quality control.

What is the Reach-In Stability Chamber?

A reach-in stability chamber is a cabinet-sized unit that holds multiple shelves of samples at controlled temperature and humidity. It is the standard choice for routine ICH stability programmes in pharmaceutical quality control.

Overview

The reach-in chamber is the workhorse of stability testing. Standing about two metres high, it provides several square metres of shelf area and enough volume for many product batches, with doors that open to allow loading by hand or from a trolley. Temperature and humidity are controlled by a refrigeration system and a humidifier, with forced-air circulation and a controlled defrost cycle. Most units include an internal light option for photostability and multiple access ports for external monitoring sensors. Conditions can usually be programmed as profiles, and redundant controllers or independent alarms protect long studies. The main advantages over a walk-in room are lower cost, simpler installation and easier control of a single condition, while capacity is limited compared with a dedicated room.

How does it work?

A stability chamber controls the environment around stored samples. Compressor or Peltier cooling removes heat, resistive or steam humidification adds moisture, and heaters raise temperature when needed, all regulated by sensors and controllers. Forced-air circulation distributes conditioned air through the chamber so temperature and humidity are uniform around every shelf position. ICH guidance defines the conditions: 25 °C and 60 percent relative humidity, or 30 °C and 65 percent relative humidity, for long-term studies, and 40 °C and 75 percent relative humidity for accelerated studies, with photostability testing under defined illumination. Continuous monitoring with alarms and chart or electronic records proves that conditions stayed within limits, and some chambers can run different zones at different conditions simultaneously.

What are the key features?

  • Cabinet-sized chamber with multiple shelves
  • Temperature and humidity control with defrost cycle
  • Forced-air circulation for shelf uniformity
  • Optional internal photostability lighting
  • Access ports for external monitoring sensors
  • Programmable profiles and redundant alarms

What are the technical specifications?

A typical reach-in stability chamber configuration offers temperature range of 5–60 °C, temperature stability of ±0.5 °C, humidity range of 40–95 percent RH, humidity stability of ±3 percent RH, chamber volume of about 400–1000 L and shelves of 4–8 adjustable. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Reach-In Stability Chamber is used in routine ICH stability studies, multiple product batches in one chamber, photostability testing and long-term reserve sample storage. Across the wider Stability Chambers class, laboratories also deploy it for ICH long-term stability studies, accelerated stability testing and photostability testing.

Which standards and certifications apply?

Relevant standards and methods include ICH Q1A(R2), ICH Q1B, ICH Q1C, IEC 61010-1, IEC 61010-2-010 and ISO 17025. Certification candidates for this model are CE, IEC 61010-1 compliance and ISO 13485 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install the chamber where ambient conditions are stable and within the manufacturer's limits, with clearance for airflow around the condensing unit. Connect a water supply or drain if humidification requires it, and prepare an emergency power plan so a failure does not destroy a long study. Map temperature and humidity at empty, partial and full load before use and after any major service, and repeat the mapping periodically. Set alarms for deviation, power loss and door-open events, and keep continuous records. Maintain the humidifier, filters and refrigeration system on schedule, and retain all monitoring data for the study period plus the required retention time.

How do I select the right Reach-In Stability Chamber?

Choose a reach-in chamber for routine stability programmes where several batches share the same condition. Confirm volume, shelf count and spacing for your sample formats, temperature and humidity stability, uniformity and defrost behaviour. Check power needs and the alarm and monitoring arrangement before installation.

How does it compare with other Stability Chambers variants?

Select a stability chamber from the ICH conditions you must support, the number of sample positions and the study duration. Benchtop units suit development and small batches; reach-in cabinets handle routine stability programmes; walk-in rooms are used when very large sample sets or many studies run in parallel. Photostability chambers add controlled illumination to the option list. Compare temperature and humidity range and stability, uniformity across shelves, recovery after door opening, alarm and monitoring systems, and whether the chamber supports multiple independent zones. Check the power, water and drainage requirements, and confirm that qualification documentation and mapping reports are provided, because regulators expect them.

Full specifications

Full specifications
Temperature range5–60 °C
Temperature stability±0.5 °C
Humidity range40–95 percent RH
Humidity stability±3 percent RH
Chamber volumeabout 400–1000 L
Shelves4–8 adjustable
MonitoringData logger, chart recorder, alarms
Power supply220 V, 50 Hz, about 2–4 kW

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Routine ICH stability studies
  • Multiple product batches in one chamber
  • Photostability testing
  • Long-term reserve sample storage

Key features

  • Cabinet-sized chamber with multiple shelves
  • Temperature and humidity control with defrost cycle
  • Forced-air circulation for shelf uniformity
  • Optional internal photostability lighting
  • Access ports for external monitoring sensors
  • Programmable profiles and redundant alarms

Frequently asked questions about Reach-In Stability Chamber

Typically four to eight adjustable shelves giving several square metres of usable area, enough for many sample bottles or blister packs. Spacing can be adjusted, but loading limits should be respected because dense loading affects air circulation and uniformity.