Walk-In Stability Chamber
步入式稳定性试验箱
- SKU STC-0003
- Stability Chambers
- CE (to be confirmed)
- IEC 61010-1 compliance (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Temperature range | 15–40 °C |
|---|---|
| Temperature stability | ±1 °C |
| Humidity range | 40–90 percent RH |
| Humidity stability | ±5 percent RH |
| Usable volume | 5–50 m3 |
| Zones | 1–4 independently controlled |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ICH Q1A(R2), ICH Q1B, ICH Q1C
What is the Walk-In Stability Chamber?
A walk-in stability chamber is a room-sized environmental space that holds very large sample sets or several studies at once. It is chosen when stability programmes outgrow cabinets and sample volumes are measured in pallets.
What is the Walk-In Stability Chamber?
A walk-in stability chamber is a room-sized environmental space that holds very large sample sets or several studies at once. It is chosen when stability programmes outgrow cabinets and sample volumes are measured in pallets.
Overview
A walk-in stability chamber is built as a room with insulated panels, its own refrigeration and humidification plant, and shelving or pallet racking. It can hold many product batches for one ICH condition, or be divided into zones that run different conditions simultaneously. Air distribution is engineered using ducts, baffles and multiple sensors so temperature and humidity remain uniform across a large volume, which makes mapping more complex than for a cabinet. Personnel can enter to load, inspect and retrieve samples, so safety features such as an internal release, emergency lighting and a door alarm are essential. Installation requires a dedicated space, substantial power, and coordination with building services for drainage and ventilation of the condensing unit.
How does it work?
A stability chamber controls the environment around stored samples. Compressor or Peltier cooling removes heat, resistive or steam humidification adds moisture, and heaters raise temperature when needed, all regulated by sensors and controllers. Forced-air circulation distributes conditioned air through the chamber so temperature and humidity are uniform around every shelf position. ICH guidance defines the conditions: 25 °C and 60 percent relative humidity, or 30 °C and 65 percent relative humidity, for long-term studies, and 40 °C and 75 percent relative humidity for accelerated studies, with photostability testing under defined illumination. Continuous monitoring with alarms and chart or electronic records proves that conditions stayed within limits, and some chambers can run different zones at different conditions simultaneously.
What are the key features?
- Room-sized insulated space with racking
- Dedicated refrigeration and humidification plant
- Engineered air distribution for large volumes
- Multiple zones for different ICH conditions
- Internal release, emergency lighting and door alarm
- Sensors at many positions for mapping
What are the technical specifications?
A typical walk-in stability chamber configuration offers temperature range of 15–40 °C, temperature stability of ±1 °C, humidity range of 40–90 percent RH, humidity stability of ±5 percent RH, usable volume of 5–50 m3 and zones of 1–4 independently controlled. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Walk-In Stability Chamber is used in large-scale stability programmes, parallel studies at different conditions, multi-product storage and contract stability testing. Across the wider Stability Chambers class, laboratories also deploy it for ICH long-term stability studies, accelerated stability testing and photostability testing.
Which standards and certifications apply?
Relevant standards and methods include ICH Q1A(R2), ICH Q1B, ICH Q1C, IEC 61010-1, IEC 61010-2-010 and ISO 17025. Certification candidates for this model are CE, IEC 61010-1 compliance and ISO 13485 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the chamber where ambient conditions are stable and within the manufacturer's limits, with clearance for airflow around the condensing unit. Connect a water supply or drain if humidification requires it, and prepare an emergency power plan so a failure does not destroy a long study. Map temperature and humidity at empty, partial and full load before use and after any major service, and repeat the mapping periodically. Set alarms for deviation, power loss and door-open events, and keep continuous records. Maintain the humidifier, filters and refrigeration system on schedule, and retain all monitoring data for the study period plus the required retention time.
How do I select the right Walk-In Stability Chamber?
Specify a walk-in chamber when sample volumes exceed cabinet capacity or several ICH conditions must run in parallel. Confirm zone count, usable volume, air distribution design, safety features and the requirements for power, drainage and building works. Insist on a full mapping report at empty, partial and full load.
How does it compare with other Stability Chambers variants?
Select a stability chamber from the ICH conditions you must support, the number of sample positions and the study duration. Benchtop units suit development and small batches; reach-in cabinets handle routine stability programmes; walk-in rooms are used when very large sample sets or many studies run in parallel. Photostability chambers add controlled illumination to the option list. Compare temperature and humidity range and stability, uniformity across shelves, recovery after door opening, alarm and monitoring systems, and whether the chamber supports multiple independent zones. Check the power, water and drainage requirements, and confirm that qualification documentation and mapping reports are provided, because regulators expect them.
Full specifications
| Temperature range | 15–40 °C |
|---|---|
| Temperature stability | ±1 °C |
| Humidity range | 40–90 percent RH |
| Humidity stability | ±5 percent RH |
| Usable volume | 5–50 m3 |
| Zones | 1–4 independently controlled |
| Monitoring | Distributed sensors and central logger |
| Power supply | 380 V, 50 Hz, about 10–40 kW |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Large-scale stability programmes
- Parallel studies at different conditions
- Multi-product storage
- Contract stability testing
Key features
- Room-sized insulated space with racking
- Dedicated refrigeration and humidification plant
- Engineered air distribution for large volumes
- Multiple zones for different ICH conditions
- Internal release, emergency lighting and door alarm
- Sensors at many positions for mapping
Frequently asked questions about Walk-In Stability Chamber
With engineered air distribution, temperature is usually held within about ±1 °C and humidity within a few percent across the qualified volume. Uniformity depends on loading, racking layout and door use, so mapping must reflect realistic operating conditions.
Yes, if the room is built with independently controlled zones separated by insulated partitions and their own air handling. Each zone needs separate mapping, monitoring and alarms, and moving between zones should not disturb conditions.
Substantial electrical supply for refrigeration and humidification, drainage for condensate and humidifier water, ventilation or heat rejection for the condensing unit, and a suitably insulated and sealed space. Early coordination with facilities and the supplier avoids later rework.
General case long-term conditions are 25 °C and 60 percent relative humidity, or 30 °C and 65 percent relative humidity, for at least 12 months. Accelerated storage is 40 °C and 75 percent relative humidity for six months, with intermediate conditions where needed.
Temperature and humidity mapping is normally done after installation, then periodically, for example annually, and again after any major repair or relocation. Mapping is performed empty, at partial load and at full load so that the usable working volume and uniformity are demonstrated.
Conditions deviate and the event must be recorded and assessed for impact on the study. A backup generator or power supply, alarm notification and documented recovery procedure limit losses, and samples exposed to out-of-specification conditions may need to be re-tested or replaced.