Benchtop Stability Chamber
台式稳定性试验箱
- SKU STC-0001
- Stability Chambers
- CE (to be confirmed)
- IEC 61010-1 compliance (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Temperature range | 5–60 °C |
|---|---|
| Temperature stability | ±0.5 °C |
| Humidity range | 40–95 percent RH |
| Humidity stability | ±3 percent RH |
| Chamber volume | about 50–150 L |
| Shelves | 2–4 adjustable |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ICH Q1A(R2), ICH Q1B, ICH Q1C
What is the Benchtop Stability Chamber?
A benchtop stability chamber provides ICH temperature and humidity control in a compact unit for small sample sets. It is chosen for development work, early stability studies and laboratories with limited floor space and budget.
What is the Benchtop Stability Chamber?
A benchtop stability chamber provides ICH temperature and humidity control in a compact unit for small sample sets. It is chosen for development work, early stability studies and laboratories with limited floor space and budget.
Overview
The benchtop stability chamber fits on or under a laboratory bench and holds a modest number of sample positions, typically a few shelves of bottles or blisters. It controls temperature and relative humidity with a compressor or Peltier element and a humidification system, and circulates air to keep conditions uniform. Most units cover the general ICH long-term and accelerated conditions, and some add a photostability lamp option. Monitoring is usually built in, with alarms and a data logger or digital record, and a small access port allows cables for external sensors. Benchtop chambers are well suited to formulation development and to holding reserve samples, but capacity and uniformity mapping must be considered, since space near the walls and door is limited.
How does it work?
A stability chamber controls the environment around stored samples. Compressor or Peltier cooling removes heat, resistive or steam humidification adds moisture, and heaters raise temperature when needed, all regulated by sensors and controllers. Forced-air circulation distributes conditioned air through the chamber so temperature and humidity are uniform around every shelf position. ICH guidance defines the conditions: 25 °C and 60 percent relative humidity, or 30 °C and 65 percent relative humidity, for long-term studies, and 40 °C and 75 percent relative humidity for accelerated studies, with photostability testing under defined illumination. Continuous monitoring with alarms and chart or electronic records proves that conditions stayed within limits, and some chambers can run different zones at different conditions simultaneously.
What are the key features?
- Compact footprint for bench or under-bench use
- Temperature and humidity control for ICH conditions
- Forced-air circulation for uniformity
- Built-in alarms and data logging
- Optional photostability lamp
- Access port for external sensor cables
What are the technical specifications?
A typical benchtop stability chamber configuration offers temperature range of 5–60 °C, temperature stability of ±0.5 °C, humidity range of 40–95 percent RH, humidity stability of ±3 percent RH, chamber volume of about 50–150 L and shelves of 2–4 adjustable. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Benchtop Stability Chamber is used in formulation development, early-phase stability studies, reserve sample storage and small-scale photostability testing. Across the wider Stability Chambers class, laboratories also deploy it for ICH long-term stability studies, accelerated stability testing and photostability testing.
Which standards and certifications apply?
Relevant standards and methods include ICH Q1A(R2), ICH Q1B, ICH Q1C, IEC 61010-1, IEC 61010-2-010 and ISO 17025. Certification candidates for this model are CE, IEC 61010-1 compliance and ISO 13485 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the chamber where ambient conditions are stable and within the manufacturer's limits, with clearance for airflow around the condensing unit. Connect a water supply or drain if humidification requires it, and prepare an emergency power plan so a failure does not destroy a long study. Map temperature and humidity at empty, partial and full load before use and after any major service, and repeat the mapping periodically. Set alarms for deviation, power loss and door-open events, and keep continuous records. Maintain the humidifier, filters and refrigeration system on schedule, and retain all monitoring data for the study period plus the required retention time.
How do I select the right Benchtop Stability Chamber?
Choose a benchtop chamber for development and small stability studies where floor space is limited. Confirm the achievable temperature and humidity range against your ICH conditions, uniformity across the working area and monitoring capability. Remember that usable shelf space is smaller than the nominal volume.
How does it compare with other Stability Chambers variants?
Select a stability chamber from the ICH conditions you must support, the number of sample positions and the study duration. Benchtop units suit development and small batches; reach-in cabinets handle routine stability programmes; walk-in rooms are used when very large sample sets or many studies run in parallel. Photostability chambers add controlled illumination to the option list. Compare temperature and humidity range and stability, uniformity across shelves, recovery after door opening, alarm and monitoring systems, and whether the chamber supports multiple independent zones. Check the power, water and drainage requirements, and confirm that qualification documentation and mapping reports are provided, because regulators expect them.
Full specifications
| Temperature range | 5–60 °C |
|---|---|
| Temperature stability | ±0.5 °C |
| Humidity range | 40–95 percent RH |
| Humidity stability | ±3 percent RH |
| Chamber volume | about 50–150 L |
| Shelves | 2–4 adjustable |
| Monitoring | Data logger with alarm |
| Power supply | 220 V, 50 Hz, about 0.8 kW |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Formulation development
- Early-phase stability studies
- Reserve sample storage
- Small-scale photostability testing
Key features
- Compact footprint for bench or under-bench use
- Temperature and humidity control for ICH conditions
- Forced-air circulation for uniformity
- Built-in alarms and data logging
- Optional photostability lamp
- Access port for external sensor cables
Frequently asked questions about Benchtop Stability Chamber
Most can reach 40 °C and 75 percent relative humidity, which is the general accelerated condition. Verify the humidity range, because achieving high humidity at high temperature can be demanding and some compact units limit operation near the top of the range.
Usable space is smaller than the internal volume because air must circulate around samples and conditions near the walls and door may differ. Follow the manufacturer's recommended load limits and mapping results to place samples only in qualified positions.
An independent monitoring system is often required, with sensors placed at validated positions and a separate data logger, so that conditions are recorded even if the chamber controller fails. This supports data integrity and audit expectations.
General case long-term conditions are 25 °C and 60 percent relative humidity, or 30 °C and 65 percent relative humidity, for at least 12 months. Accelerated storage is 40 °C and 75 percent relative humidity for six months, with intermediate conditions where needed.
Temperature and humidity mapping is normally done after installation, then periodically, for example annually, and again after any major repair or relocation. Mapping is performed empty, at partial load and at full load so that the usable working volume and uniformity are demonstrated.
Conditions deviate and the event must be recorded and assessed for impact on the study. A backup generator or power supply, alarm notification and documented recovery procedure limit losses, and samples exposed to out-of-specification conditions may need to be re-tested or replaced.