Turbidity Meters

浊度计

TME · Water Testing Equipment · 5 models

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 7027-1, ISO 7027-2, EPA 180.1

Standards referenced

  • ISO 7027-1
  • ISO 7027-2
  • EPA 180.1
  • Standard Methods 2130 B
  • ISO/IEC 17025

What are Turbidity Meters?

Turbidity meters measure the cloudiness of water from the light scattered by suspended particles. The subcategory covers portable and benchtop nephelometers, ratio and backscatter instruments and online analyzers used for drinking water compliance and wastewater and process control.

5 models of Turbidity Meters

The 5 models below are current configurations; specifications are confirmed on quotation.

Portable Nephelometric Turbidity Meter

便携式散射浊度计

  • TME-0001
  • Turbidity Meters
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • ISO 7027 design compliance (to be confirmed)
Method compliance:
ISO 7027 or EPA 180.1, model specific
Range:
0–1000 NTU
Resolution:
0.01 NTU below 10 NTU, 1 NTU above
Accuracy:
±2 percent of reading plus 0.01 NTU
Light source:
LED, 860 nm or tungsten
Detector:
Silicon photodiode at 90 degrees

A portable nephelometric turbidity meter measures 90-degree light scatter in a battery-powered handheld or field case format. It brings compliant turbidity readings directly to rivers, wells, treatment works and remote sampling points.

Request a quote
View details

Benchtop Turbidity Meter for Drinking Water

饮用水台式浊度计

  • TME-0002
  • Turbidity Meters
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • ISO 7027 design compliance (to be confirmed)
Range:
0–1000 NTU
Low-range resolution:
0.001 NTU or 0.01 NTU
Accuracy:
±2 percent of reading plus 0.01 NTU
Measurement modes:
Nephelometric and ratio
Light source:
LED 860 nm, ISO 7027 design
Detector geometry:
90 degrees plus ratio detectors

A benchtop turbidity meter measures low-level turbidity in drinking water with stable optics and controlled temperature. It delivers the repeatability, low detection limits and documentation required for regulatory drinking water compliance testing.

Request a quote
View details

Ratio Turbidity Meter with Dual Detectors

双检测器比值式浊度计

  • TME-0003
  • Turbidity Meters
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Detectors:
90 degree plus forward scatter
Range:
0–10,000 NTU in ratio mode
Resolution:
0.01 NTU below 10 NTU
Accuracy:
±2 percent of reading plus 0.01 NTU
Light source:
LED 860 nm or tungsten
Modes:
Nephelometric and ratio

A ratio turbidity meter uses two or more detectors at different angles and divides their signals to compensate for colour and lamp drift. It measures coloured, absorbing and moderately turbid water more reliably than single-detector nephelometers.

Request a quote
View details

Online Turbidity Analyzer for Water Treatment

水处理在线浊度分析仪

  • TME-0004
  • Turbidity Meters
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Range:
0–100 or 0–4000 NTU, model specific
Resolution:
0.001 NTU at low range
Accuracy:
±2 percent of reading or better
Measurement mode:
Flow-through or immersion
Cleaning:
Air blast, wiper or ultrasonic
Output signals:
4–20 mA, Modbus, Ethernet

An online turbidity analyzer continuously measures turbidity in a flowing water stream and transmits the result to plant control. It supports coagulation, filtration and backwash control in drinking water and wastewater plants.

Request a quote
View details

Backscatter Turbidity Meter for High-Range Samples

高量程背散射浊度计

  • TME-0005
  • Turbidity Meters
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Detection angle:
135–180 degrees backscatter
Range:
0–200 g/L suspended solids
Resolution:
1 mg/L at low range
Light source:
Near-infrared LED
Calibration:
NTU and suspended solids units
Cleaning:
Wiper or air blast

A backscatter turbidity meter measures light returned at angles greater than 90 degrees, allowing measurement of raw wastewater, sludge and concentrated slurries. It extends the useful measuring range far beyond that of conventional nephelometric instruments.

Request a quote
View details

Compare Turbidity Meters models

ModelRangeResolutionAccuracyLight sourceCalibration
Portable Nephelometric Turbidity MeterTME-00010–1000 NTU0.01 NTU below 10 NTU, 1 NTU above±2 percent of reading plus 0.01 NTULED, 860 nm or tungstenUp to 4 points, sealed standards
Benchtop Turbidity Meter for Drinking WaterTME-00020–1000 NTU—±2 percent of reading plus 0.01 NTULED 860 nm, ISO 7027 design—
Ratio Turbidity Meter with Dual DetectorsTME-00030–10,000 NTU in ratio mode0.01 NTU below 10 NTU±2 percent of reading plus 0.01 NTULED 860 nm or tungstenUp to 6 points with standards
Online Turbidity Analyzer for Water TreatmentTME-00040–100 or 0–4000 NTU, model specific0.001 NTU at low range±2 percent of reading or better——
Backscatter Turbidity Meter for High-Range SamplesTME-00050–200 g/L suspended solids1 mg/L at low range—Near-infrared LEDNTU and suspended solids units

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do Turbidity Meters work?

Nephelometric turbidity measurement shines a light beam into the sample and measures the light scattered at 90 degrees by suspended particles, since scattering increases with particle number, size and refractive index. ISO 7027 specifies the optical design, including wavelength and detector geometry, while EPA 180.1 specifies a tungsten lamp and a slightly different geometry, so instruments are usually labelled to one method. Ratio turbidimeters add a second or third detector at other angles and divide the signals, which compensates for colour and lamp ageing and extends the useful range. Backscatter instruments measure light scattered at angles greater than 90 degrees and suit high-turbidity samples beyond the range of nephelometry. Turbidity is formally a ratio of scattered to transmitted light and is reported in nephelometric turbidity units (NTU).

Which Turbidity Meters variants are available?

  • Portable Nephelometric Turbidity Meter — A portable nephelometric turbidity meter measures 90-degree light scatter in a battery-powered handheld or field case format.
  • Benchtop Turbidity Meter for Drinking Water — A benchtop turbidity meter measures low-level turbidity in drinking water with stable optics and controlled temperature.
  • Ratio Turbidity Meter with Dual Detectors — A ratio turbidity meter uses two or more detectors at different angles and divides their signals to compensate for colour and lamp drift.
  • Online Turbidity Analyzer for Water Treatment — An online turbidity analyzer continuously measures turbidity in a flowing water stream and transmits the result to plant control.
  • Backscatter Turbidity Meter for High-Range Samples — A backscatter turbidity meter measures light returned at angles greater than 90 degrees, allowing measurement of raw wastewater, sludge and concentrated slurries.

How do I choose the right variant?

Start from the method named in your regulation, because ISO 7027 and EPA 180.1 instruments are not interchangeable for compliance reporting. Portable meters suit field checks, river surveys and emergency sampling, while benchtop instruments give better repeatability and temperature control for laboratory compliance work. Ratio turbidimeters handle coloured or strongly absorbing samples better and reduce the effect of lamp drift. Choose a backscatter instrument when samples exceed the nephelometric range, as in sludge and raw wastewater. Online analyzers provide continuous data for filtration and coagulation control and are typically calibrated against the laboratory meter. Confirm the calibration standards, the range required and whether low-level resolution near 0.02 NTU is needed.

Where are Turbidity Meters used?

Turbidity Meters are specified in drinking water turbidity compliance testing, filter performance and backwash control, raw water and river quality monitoring, wastewater effluent and sludge measurement, beverage and pharmaceutical water quality checks and coagulation and settling process optimisation.

Which standards and certifications apply?

Work with Turbidity Meters is commonly governed by ISO 7027-1, ISO 7027-2, EPA 180.1, Standard Methods 2130 B and ISO/IEC 17025. Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

Turbidity is sensitive to handling, so sample bottles should be clean and free of scratches, and measurements should be made promptly because particles settle and temperature changes. Dilution changes the particle population and is generally avoided. Formazin is the primary standard but is toxic and unstable, so stabilised formazin or polymer standards are used routinely and replaced before expiry. Low-level instruments need careful zeroing with ultrapure water and checks for stray light and bubbles, which cause positive bias. Online instruments require scheduled cleaning of the optical windows and verification against grab samples. Keep calibration records, and note the method and instrument model on every report, since results from different optical designs are not directly comparable.

Frequently asked questions about Turbidity Meters

NTU stands for nephelometric turbidity unit, the scale used to report turbidity measured by light scattering at 90 degrees. It is defined against formazin standards, and instruments calibrated to different optical geometries may report different values for the same sample.