Chlorine Meters

余氯计

CHM · Water Testing Equipment · 5 models

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 7393-1, ISO 7393-2, ISO 7393-3

Standards referenced

  • ISO 7393-1
  • ISO 7393-2
  • ISO 7393-3
  • EPA 330.5
  • Standard Methods 4500-Cl G
  • ISO/IEC 17025

What are Chlorine Meters?

Chlorine meters measure free and total residual chlorine in drinking water, pools and industrial process water. The subcategory covers portable and benchtop DPD colorimeters, pocket testers and online amperometric or optical analyzers used for disinfection control and compliance.

5 models of Chlorine Meters

The 5 models below are current configurations; specifications are confirmed on quotation.

Portable DPD Chlorine Colorimeter

便携式 DPD 余氯比色仪

  • CHM-0001
  • Chlorine Meters
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Parameters:
Free, combined and total chlorine
Ranges:
0–6 mg/L and 0–200 mg/L (high range)
Resolution:
0.01 mg/L at low range
Wavelengths:
515 nm and 555 nm for high range
Accuracy:
±3 percent of reading
Sample volume:
10 mL

A portable DPD chlorine colorimeter measures free, combined and total chlorine in the field using tablet or powder reagents and a photometer. It brings reliable disinfection checks to treatment works, pools and distribution sampling points.

Request a quote
View details

Benchtop Chlorine Colorimeter

台式余氯比色仪

  • CHM-0002
  • Chlorine Meters
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Parameters:
Free, monochloramine, dichloramine, total chlorine
Ranges:
0–5 mg/L low, up to 0–200 mg/L high
Resolution:
0.01 mg/L
Wavelength accuracy:
±1 nm
Optical system:
Interference filters or monochromator
Sample cell:
10 mm or 20 mm cuvette

A benchtop chlorine colorimeter measures free, combined and total chlorine with stable optics and controlled wavelength selection. It provides the repeatability needed to verify portable field meters and to support routine laboratory reporting.

Request a quote
View details

Online Amperometric Residual Chlorine Analyzer

在线电流型余氯分析仪

  • CHM-0003
  • Chlorine Meters
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Measurement principle:
Amperometric with chlorine-permeable membrane
Range:
0–2 mg/L, 0–20 mg/L selectable
Resolution:
0.01 mg/L
Response time:
90 percent in under 60 s
pH range:
6.0–9.0 with compensation
Sample flow:
0.2–1 L/min

An online amperometric chlorine analyzer measures residual chlorine continuously with a membrane-covered electrode. It responds in seconds and drives chemical dosing pumps and alarm systems for drinking water and wastewater disinfection control.

Request a quote
View details

Pocket Chlorine Tester for Field Use

袖珍式现场余氯测试仪

  • CHM-0004
  • Chlorine Meters
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Parameters:
Free or total chlorine
Range:
0–5 mg/L
Resolution:
0.01 mg/L
Wavelength:
515 nm DPD
Accuracy:
±5 percent of reading
Sample volume:
10 mL

A pocket chlorine tester is a compact, low-cost photometer for single readings of free or total chlorine. It suits pool operators, field staff and small facilities that need a quick disinfection check without a full laboratory method.

Request a quote
View details

Optical Chlorine Analyzer for Drinking Water Plants

饮用水厂光学余氯分析仪

  • CHM-0005
  • Chlorine Meters
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Measurement principle:
DPD colorimetry in a flow cell
Range:
0–2 mg/L or 0–5 mg/L
Detection limit:
0.01 mg/L
Wavelength:
515 nm
Cycle time:
2–5 min per measurement
Reagent consumption:
1–5 mL per measurement

An optical chlorine analyzer performs a colorimetric reaction in a flow cell with automatic reagent dosing to measure residual chlorine continuously. It needs reagent replenishment but avoids sensor membrane maintenance and drift.

Request a quote
View details

Compare Chlorine Meters models

ModelParametersRangesResolutionAccuracySample volume
Portable DPD Chlorine ColorimeterCHM-0001Free, combined and total chlorine0–6 mg/L and 0–200 mg/L (high range)0.01 mg/L at low range±3 percent of reading10 mL
Benchtop Chlorine ColorimeterCHM-0002Free, monochloramine, dichloramine, total chlorine0–5 mg/L low, up to 0–200 mg/L high0.01 mg/L——
Online Amperometric Residual Chlorine AnalyzerCHM-0003——0.01 mg/L——
Pocket Chlorine Tester for Field UseCHM-0004Free or total chlorine—0.01 mg/L±5 percent of reading10 mL
Optical Chlorine Analyzer for Drinking Water PlantsCHM-0005—————

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do Chlorine Meters work?

Chlorine measurement uses either a colorimetric or an electrochemical principle. In the DPD method, N,N-diethyl-p-phenylenediamine reacts with free chlorine to form a magenta colour whose intensity is proportional to concentration and is measured at about 515 nm; adding potassium iodide then reveals combined chlorine so total chlorine can be determined. Because the colour develops quickly and fades, timing and temperature must be controlled. Amperometric analyzers use a membrane-covered electrode where chlorine diffuses to a cathode and produces a current proportional to concentration, giving continuous measurement without reagents. Optical analyzers use a colorimetric reaction in a flow cell with automatic reagent addition. Results are reported in milligrams per litre as free chlorine, combined chlorine, total chlorine or, in pools, as total chlorine with cyanuric acid present.

Which Chlorine Meters variants are available?

  • Portable DPD Chlorine Colorimeter — A portable DPD chlorine colorimeter measures free, combined and total chlorine in the field using tablet or powder reagents and a photometer.
  • Benchtop Chlorine Colorimeter — A benchtop chlorine colorimeter measures free, combined and total chlorine with stable optics and controlled wavelength selection.
  • Online Amperometric Residual Chlorine Analyzer — An online amperometric chlorine analyzer measures residual chlorine continuously with a membrane-covered electrode.
  • Pocket Chlorine Tester for Field Use — A pocket chlorine tester is a compact, low-cost photometer for single readings of free or total chlorine.
  • Optical Chlorine Analyzer for Drinking Water Plants — An optical chlorine analyzer performs a colorimetric reaction in a flow cell with automatic reagent dosing to measure residual chlorine continuously.

How do I choose the right variant?

Choose the measurement format from where and how often chlorine is measured. Pocket testers and portable colorimeters suit field checks, pool testing and distribution system sampling, where speed and portability matter. Benchtop colorimeters give better optics and repeatability for laboratories and for verifying portable meters. Online amperometric analyzers are needed wherever chlorine dosing must be continuous, as at treatment works, since they respond in seconds and can drive pumps and alarms directly. Consider the expected range, since disinfection residuals are usually 0.2 to 2 mg/L but pool and shock dosing levels are far higher, and confirm whether free, combined or total chlorine is the reported parameter. Check reagent or membrane availability and the calibration standards you will need.

Where are Chlorine Meters used?

Chlorine Meters are specified in drinking water disinfection monitoring, swimming pool and spa water testing, wastewater effluent chlorination control, food and beverage plant water hygiene, cooling water and industrial process control and distribution network residual chlorine surveys.

Which standards and certifications apply?

Work with Chlorine Meters is commonly governed by ISO 7393-1, ISO 7393-2, ISO 7393-3, EPA 330.5, Standard Methods 4500-Cl G and ISO/IEC 17025. Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

DPD reagents and powder pillows have a limited shelf life and are sensitive to heat and moisture, so they must be stored correctly and replaced before expiry. Colour development depends on time and temperature, so sample temperature should be near 20 to 25 °C and readings taken within the specified period. High chlorine concentrations bleach the colour and need dilution, and samples with manganese, ozone or high turbidity can interfere. Membrane electrodes need electrolyte replacement, membrane care and regular calibration against a reference method, and the sample flow, pH and temperature must be within the specified limits. For pools, cyanuric acid affects the ratio of free to combined chlorine and should be known. Keep records of calibration, reagents and reference comparisons.

Frequently asked questions about Chlorine Meters

Free chlorine is hypochlorous acid and hypochlorite ion, the active disinfecting forms. Combined chlorine is chlorine bound to ammonia as chloramines, which is a weaker disinfectant. Total chlorine is the sum of the two and is measured by adding iodide in the DPD method.

Need help specifying Chlorine Meters?

Request a quote