Optical Chlorine Analyzer for Drinking Water Plants
饮用水厂光学余氯分析仪
- SKU CHM-0005
- Chlorine Meters
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Measurement principle | DPD colorimetry in a flow cell |
|---|---|
| Range | 0–2 mg/L or 0–5 mg/L |
| Detection limit | 0.01 mg/L |
| Wavelength | 515 nm |
| Cycle time | 2–5 min per measurement |
| Reagent consumption | 1–5 mL per measurement |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 7393-1, ISO 7393-2, ISO 7393-3
What is the Optical Chlorine Analyzer for Drinking Water Plants?
An optical chlorine analyzer performs a colorimetric reaction in a flow cell with automatic reagent dosing to measure residual chlorine continuously. It needs reagent replenishment but avoids sensor membrane maintenance and drift.
What is the Optical Chlorine Analyzer for Drinking Water Plants?
An optical chlorine analyzer performs a colorimetric reaction in a flow cell with automatic reagent dosing to measure residual chlorine continuously. It needs reagent replenishment but avoids sensor membrane maintenance and drift.
Overview
The analyzer mixes a small measured volume of sample with DPD reagent in a reaction coil or flow cell, waits for colour development and measures absorbance at about 515 nm. Free and total chlorine can be determined in separate channels or sequentially, and the result is transmitted to the plant control system. Because the measurement is based on a defined chemical reaction, it is traceable to the standard DPD method and less dependent on membrane condition, but reagent consumption requires regular replacement of containers and tubing, and the reaction cell needs cleaning. Typical ranges are 0 to 2 mg/L or 0 to 5 mg/L with detection limits near 0.01 mg/L, and cleaning cycles are scheduled according to the fouling rate of the sample stream. Calibration is verified with grab samples analysed by the reference method.
How does it work?
Chlorine measurement uses either a colorimetric or an electrochemical principle. In the DPD method, N,N-diethyl-p-phenylenediamine reacts with free chlorine to form a magenta colour whose intensity is proportional to concentration and is measured at about 515 nm; adding potassium iodide then reveals combined chlorine so total chlorine can be determined. Because the colour develops quickly and fades, timing and temperature must be controlled. Amperometric analyzers use a membrane-covered electrode where chlorine diffuses to a cathode and produces a current proportional to concentration, giving continuous measurement without reagents. Optical analyzers use a colorimetric reaction in a flow cell with automatic reagent addition. Results are reported in milligrams per litre as free chlorine, combined chlorine, total chlorine or, in pools, as total chlorine with cyanuric acid present.
What are the key features?
- Automatic reagent dosing with colorimetric detection
- Free and total chlorine channels or sequential measurement
- Traceable to the standard DPD colorimetric method
- No membrane or electrolyte to maintain
- Automatic cleaning of the reaction cell
- Outputs for dosing control and alarms
What are the technical specifications?
A typical optical chlorine analyzer for drinking water plants configuration offers measurement principle of DPD colorimetry in a flow cell, range of 0–2 mg/L or 0–5 mg/L, detection limit of 0.01 mg/L, wavelength of 515 nm, cycle time of 2–5 min per measurement and reagent consumption of 1–5 mL per measurement. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Optical Chlorine Analyzer for Drinking Water Plants is used in drinking water treatment residual control, distribution network chlorine monitoring, wastewater effluent chlorination verification and industrial water disinfection control. Across the wider Chlorine Meters class, laboratories also deploy it for drinking water disinfection monitoring, swimming pool and spa water testing and wastewater effluent chlorination control.
Which standards and certifications apply?
Relevant standards and methods include ISO 7393-1, ISO 7393-2, ISO 7393-3, EPA 330.5, Standard Methods 4500-Cl G and ISO/IEC 17025. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
DPD reagents and powder pillows have a limited shelf life and are sensitive to heat and moisture, so they must be stored correctly and replaced before expiry. Colour development depends on time and temperature, so sample temperature should be near 20 to 25 °C and readings taken within the specified period. High chlorine concentrations bleach the colour and need dilution, and samples with manganese, ozone or high turbidity can interfere. Membrane electrodes need electrolyte replacement, membrane care and regular calibration against a reference method, and the sample flow, pH and temperature must be within the specified limits. For pools, cyanuric acid affects the ratio of free to combined chlorine and should be known. Keep records of calibration, reagents and reference comparisons.
How do I select the right Optical Chlorine Analyzer for Drinking Water Plants?
Choose an optical analyzer when a continuous measurement traceable to the DPD method is preferred over membrane sensor maintenance. Confirm the measurement interval suits your dosing control loop, that reagent supply and disposal can be managed, and that the range covers your operating residual.
How does it compare with other Chlorine Meters variants?
Choose the measurement format from where and how often chlorine is measured. Pocket testers and portable colorimeters suit field checks, pool testing and distribution system sampling, where speed and portability matter. Benchtop colorimeters give better optics and repeatability for laboratories and for verifying portable meters. Online amperometric analyzers are needed wherever chlorine dosing must be continuous, as at treatment works, since they respond in seconds and can drive pumps and alarms directly. Consider the expected range, since disinfection residuals are usually 0.2 to 2 mg/L but pool and shock dosing levels are far higher, and confirm whether free, combined or total chlorine is the reported parameter. Check reagent or membrane availability and the calibration standards you will need.
Full specifications
| Measurement principle | DPD colorimetry in a flow cell |
|---|---|
| Range | 0–2 mg/L or 0–5 mg/L |
| Detection limit | 0.01 mg/L |
| Wavelength | 515 nm |
| Cycle time | 2–5 min per measurement |
| Reagent consumption | 1–5 mL per measurement |
| Sample flow | 0.1–0.5 L/min |
| Outputs | 4–20 mA, Modbus, Ethernet |
| Reagent container | 1–5 L, replaceable |
| Enclosure | IP65 |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Drinking water treatment residual control
- Distribution network chlorine monitoring
- Wastewater effluent chlorination verification
- Industrial water disinfection control
Key features
- Automatic reagent dosing with colorimetric detection
- Free and total chlorine channels or sequential measurement
- Traceable to the standard DPD colorimetric method
- No membrane or electrolyte to maintain
- Automatic cleaning of the reaction cell
- Outputs for dosing control and alarms
Frequently asked questions about Optical Chlorine Analyzer for Drinking Water Plants
Optical measurement is based on the standard DPD reaction, so results are directly comparable with grab sample analysis and are unaffected by membrane ageing. The trade-offs are reagent consumption, longer measurement intervals and reagent disposal.
Depends on the measurement interval and reagent volume per test. A five-minute cycle with 2 mL per measurement consumes about 0.6 L per day, so a 5 L container lasts roughly a week of continuous operation.
Reagent residues, scale and biofilm accumulate in the flow cell and bias absorbance readings or block flow. Automatic rinse cycles with water or cleaning solution keep the optical path clear and extend the interval between manual services.
Free chlorine is hypochlorous acid and hypochlorite ion, the active disinfecting forms. Combined chlorine is chlorine bound to ammonia as chloramines, which is a weaker disinfectant. Total chlorine is the sum of the two and is measured by adding iodide in the DPD method.
The magenta colour develops quickly, then slowly fades as the reaction proceeds and the dye oxidises further. Readings should be taken within one to two minutes of reagent addition, and sample temperature should be near 20 to 25 °C for consistent colour development.
Chlorine diffuses through a membrane to a cathode where it is reduced, producing a current proportional to concentration. The sensor is calibrated against a DPD or reference method and measures continuously, which suits dosing control and alarm functions.
Related models