Pocket Chlorine Tester for Field Use
袖珍式现场余氯测试仪
- SKU CHM-0004
- Chlorine Meters
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Parameters | Free or total chlorine |
|---|---|
| Range | 0–5 mg/L |
| Resolution | 0.01 mg/L |
| Wavelength | 515 nm DPD |
| Accuracy | ±5 percent of reading |
| Sample volume | 10 mL |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 7393-1, ISO 7393-2, ISO 7393-3
What is the Pocket Chlorine Tester for Field Use?
A pocket chlorine tester is a compact, low-cost photometer for single readings of free or total chlorine. It suits pool operators, field staff and small facilities that need a quick disinfection check without a full laboratory method.
What is the Pocket Chlorine Tester for Field Use?
A pocket chlorine tester is a compact, low-cost photometer for single readings of free or total chlorine. It suits pool operators, field staff and small facilities that need a quick disinfection check without a full laboratory method.
Overview
The tester accepts a small vial or a pre-filled cuvette with reagent, and a single button performs zeroing and measurement at the DPD wavelength. Displays usually show 0 to 5 mg/L with 0.01 mg/L resolution, and some models store the last readings or have a simple log. Because optics are small and there is no temperature control, readings are less repeatable than with laboratory instruments, so the device is best used for frequent operational checks rather than compliance reporting. Reagents are supplied as tablets, powder pillows or pre-dosed cuvettes, and the instrument should be kept clean and dry with periodic verification against a benchtop colorimeter using the same reagent lot.
How does it work?
Chlorine measurement uses either a colorimetric or an electrochemical principle. In the DPD method, N,N-diethyl-p-phenylenediamine reacts with free chlorine to form a magenta colour whose intensity is proportional to concentration and is measured at about 515 nm; adding potassium iodide then reveals combined chlorine so total chlorine can be determined. Because the colour develops quickly and fades, timing and temperature must be controlled. Amperometric analyzers use a membrane-covered electrode where chlorine diffuses to a cathode and produces a current proportional to concentration, giving continuous measurement without reagents. Optical analyzers use a colorimetric reaction in a flow cell with automatic reagent addition. Results are reported in milligrams per litre as free chlorine, combined chlorine, total chlorine or, in pools, as total chlorine with cyanuric acid present.
What are the key features?
- Single-button zero and measure operation
- Compact pocket format with rechargeable or coin cell power
- Range 0–5 mg/L with 0.01 mg/L resolution
- Tablet, powder or pre-dosed cuvette reagents
- Simple reading log on selected models
- Low cost per test for frequent checks
What are the technical specifications?
A typical pocket chlorine tester for field use configuration offers parameters of Free or total chlorine, range of 0–5 mg/L, resolution of 0.01 mg/L, wavelength of 515 nm DPD, accuracy of ±5 percent of reading and sample volume of 10 mL. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Pocket Chlorine Tester for Field Use is used in swimming pool and spa routine checks, small water system disinfection monitoring, food service and catering water checks and field and emergency water treatment. Across the wider Chlorine Meters class, laboratories also deploy it for drinking water disinfection monitoring, swimming pool and spa water testing and wastewater effluent chlorination control.
Which standards and certifications apply?
Relevant standards and methods include ISO 7393-1, ISO 7393-2, ISO 7393-3, EPA 330.5, Standard Methods 4500-Cl G and ISO/IEC 17025. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
DPD reagents and powder pillows have a limited shelf life and are sensitive to heat and moisture, so they must be stored correctly and replaced before expiry. Colour development depends on time and temperature, so sample temperature should be near 20 to 25 °C and readings taken within the specified period. High chlorine concentrations bleach the colour and need dilution, and samples with manganese, ozone or high turbidity can interfere. Membrane electrodes need electrolyte replacement, membrane care and regular calibration against a reference method, and the sample flow, pH and temperature must be within the specified limits. For pools, cyanuric acid affects the ratio of free to combined chlorine and should be known. Keep records of calibration, reagents and reference comparisons.
How do I select the right Pocket Chlorine Tester for Field Use?
Choose a pocket tester for frequent, low-cost operational checks where a laboratory instrument is impractical. Accept that repeatability is lower, and verify the device periodically against a benchtop colorimeter using the same reagent lot if readings influence operational or regulatory decisions.
How does it compare with other Chlorine Meters variants?
Choose the measurement format from where and how often chlorine is measured. Pocket testers and portable colorimeters suit field checks, pool testing and distribution system sampling, where speed and portability matter. Benchtop colorimeters give better optics and repeatability for laboratories and for verifying portable meters. Online amperometric analyzers are needed wherever chlorine dosing must be continuous, as at treatment works, since they respond in seconds and can drive pumps and alarms directly. Consider the expected range, since disinfection residuals are usually 0.2 to 2 mg/L but pool and shock dosing levels are far higher, and confirm whether free, combined or total chlorine is the reported parameter. Check reagent or membrane availability and the calibration standards you will need.
Full specifications
| Parameters | Free or total chlorine |
|---|---|
| Range | 0–5 mg/L |
| Resolution | 0.01 mg/L |
| Wavelength | 515 nm DPD |
| Accuracy | ±5 percent of reading |
| Sample volume | 10 mL |
| Reagent formats | Tablet, powder pillow, pre-dosed cuvette |
| Data storage | Last 10–50 readings |
| Power | Coin cell or rechargeable battery |
| Protection | IP65 or better |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Swimming pool and spa routine checks
- Small water system disinfection monitoring
- Food service and catering water checks
- Field and emergency water treatment
Key features
- Single-button zero and measure operation
- Compact pocket format with rechargeable or coin cell power
- Range 0–5 mg/L with 0.01 mg/L resolution
- Tablet, powder or pre-dosed cuvette reagents
- Simple reading log on selected models
- Low cost per test for frequent checks
Frequently asked questions about Pocket Chlorine Tester for Field Use
Usually not. Its optics and temperature stability are limited, so results carry more uncertainty than a benchtop colorimeter or a laboratory method. It is best used for frequent operational checks, with formal results from a validated method.
Use the same reagent lot for a series of readings, let samples reach about 20 to 25 °C, fill vials to exactly the mark, wipe them with a lint-free cloth and read within the time stated in the instructions.
Replace or service the tester when verification against a benchtop instrument shows persistent bias, when the display or vials are damaged, or when the manufacturer's verification interval has passed without acceptable results.
Free chlorine is hypochlorous acid and hypochlorite ion, the active disinfecting forms. Combined chlorine is chlorine bound to ammonia as chloramines, which is a weaker disinfectant. Total chlorine is the sum of the two and is measured by adding iodide in the DPD method.
The magenta colour develops quickly, then slowly fades as the reaction proceeds and the dye oxidises further. Readings should be taken within one to two minutes of reagent addition, and sample temperature should be near 20 to 25 °C for consistent colour development.
Chlorine diffuses through a membrane to a cathode where it is reduced, producing a current proportional to concentration. The sensor is calibrated against a DPD or reference method and measures continuously, which suits dosing control and alarm functions.
Related models