Benchtop Turbidity Meter for Drinking Water
饮用水台式浊度计
- SKU TME-0002
- Turbidity Meters
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- ISO 7027 design compliance (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Range | 0–1000 NTU |
|---|---|
| Low-range resolution | 0.001 NTU or 0.01 NTU |
| Accuracy | ±2 percent of reading plus 0.01 NTU |
| Measurement modes | Nephelometric and ratio |
| Light source | LED 860 nm, ISO 7027 design |
| Detector geometry | 90 degrees plus ratio detectors |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 7027-1, ISO 7027-2, EPA 180.1
What is the Benchtop Turbidity Meter for Drinking Water?
A benchtop turbidity meter measures low-level turbidity in drinking water with stable optics and controlled temperature. It delivers the repeatability, low detection limits and documentation required for regulatory drinking water compliance testing.
What is the Benchtop Turbidity Meter for Drinking Water?
A benchtop turbidity meter measures low-level turbidity in drinking water with stable optics and controlled temperature. It delivers the repeatability, low detection limits and documentation required for regulatory drinking water compliance testing.
Overview
The instrument places a sample vial in a temperature-stabilised optical assembly and measures 90-degree scatter with a low-noise detector, giving resolution of 0.001 to 0.01 NTU and accuracy of ±2 percent of reading plus 0.01 NTU. Many models add a ratio mode that divides the 90-degree signal by signals from forward or back detectors, reducing sensitivity to colour, lamp ageing and vial variation. Calibration uses a multi-point series of formazin or polymer standards, and sealed primary standards are supplied for routine verification. For very low levels, the instrument provides a zero point with filtered water and reports stray light, which sets the practical lower limit. Data logging, GLP records and printed reports support the traceability regulators expect.
How does it work?
Nephelometric turbidity measurement shines a light beam into the sample and measures the light scattered at 90 degrees by suspended particles, since scattering increases with particle number, size and refractive index. ISO 7027 specifies the optical design, including wavelength and detector geometry, while EPA 180.1 specifies a tungsten lamp and a slightly different geometry, so instruments are usually labelled to one method. Ratio turbidimeters add a second or third detector at other angles and divide the signals, which compensates for colour and lamp ageing and extends the useful range. Backscatter instruments measure light scattered at angles greater than 90 degrees and suit high-turbidity samples beyond the range of nephelometry. Turbidity is formally a ratio of scattered to transmitted light and is reported in nephelometric turbidity units (NTU).
What are the key features?
- Resolution of 0.001–0.01 NTU for low-level measurement
- Ratio mode with additional detectors for colour compensation
- Temperature-stabilised optical assembly
- Multi-point calibration with sealed primary standards
- Stray light reporting and filtered-water zero point
- GLP data records and printed reports
What are the technical specifications?
A typical benchtop turbidity meter for drinking water configuration offers range of 0–1000 NTU, low-range resolution of 0.001 NTU or 0.01 NTU, accuracy of ±2 percent of reading plus 0.01 NTU, measurement modes of Nephelometric and ratio, light source of LED 860 nm, ISO 7027 design and detector geometry of 90 degrees plus ratio detectors. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Benchtop Turbidity Meter for Drinking Water is used in drinking water turbidity compliance testing, filter effluent monitoring at treatment works, beverage and pharmaceutical water control and calibration reference for online turbidimeters. Across the wider Turbidity Meters class, laboratories also deploy it for drinking water turbidity compliance testing, filter performance and backwash control and raw water and river quality monitoring.
Which standards and certifications apply?
Relevant standards and methods include ISO 7027-1, ISO 7027-2, EPA 180.1, Standard Methods 2130 B and ISO/IEC 17025. Certification candidates for this model are CE, ISO 9001 manufacturing and ISO 7027 design compliance; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Turbidity is sensitive to handling, so sample bottles should be clean and free of scratches, and measurements should be made promptly because particles settle and temperature changes. Dilution changes the particle population and is generally avoided. Formazin is the primary standard but is toxic and unstable, so stabilised formazin or polymer standards are used routinely and replaced before expiry. Low-level instruments need careful zeroing with ultrapure water and checks for stray light and bubbles, which cause positive bias. Online instruments require scheduled cleaning of the optical windows and verification against grab samples. Keep calibration records, and note the method and instrument model on every report, since results from different optical designs are not directly comparable.
How do I select the right Benchtop Turbidity Meter for Drinking Water?
Choose a benchtop instrument when low-level turbidity must be reported for compliance and you need the best repeatability available. Confirm the method design (ISO 7027 or EPA 180.1), the resolution near zero and whether ratio measurement is required for coloured samples.
How does it compare with other Turbidity Meters variants?
Start from the method named in your regulation, because ISO 7027 and EPA 180.1 instruments are not interchangeable for compliance reporting. Portable meters suit field checks, river surveys and emergency sampling, while benchtop instruments give better repeatability and temperature control for laboratory compliance work. Ratio turbidimeters handle coloured or strongly absorbing samples better and reduce the effect of lamp drift. Choose a backscatter instrument when samples exceed the nephelometric range, as in sludge and raw wastewater. Online analyzers provide continuous data for filtration and coagulation control and are typically calibrated against the laboratory meter. Confirm the calibration standards, the range required and whether low-level resolution near 0.02 NTU is needed.
Full specifications
| Range | 0–1000 NTU |
|---|---|
| Low-range resolution | 0.001 NTU or 0.01 NTU |
| Accuracy | ±2 percent of reading plus 0.01 NTU |
| Measurement modes | Nephelometric and ratio |
| Light source | LED 860 nm, ISO 7027 design |
| Detector geometry | 90 degrees plus ratio detectors |
| Calibration points | Up to 6 with sealed standards |
| Sample temperature | 0–50 °C compensated |
| Data storage | 1000+ GLP records |
| Interface | USB, RS-232, printer, LIMS export |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Drinking water turbidity compliance testing
- Filter effluent monitoring at treatment works
- Beverage and pharmaceutical water control
- Calibration reference for online turbidimeters
Key features
- Resolution of 0.001–0.01 NTU for low-level measurement
- Ratio mode with additional detectors for colour compensation
- Temperature-stabilised optical assembly
- Multi-point calibration with sealed primary standards
- Stray light reporting and filtered-water zero point
- GLP data records and printed reports
Frequently asked questions about Benchtop Turbidity Meter for Drinking Water
Ratio turbidimeters divide the 90-degree scatter signal by signals from additional detectors at other angles. This compensates for sample colour, lamp intensity changes and vial variability, so readings are more stable in coloured or turbid samples.
Stray light is the small signal recorded with a zero sample, arising from optics, electronics and vial imperfections. It sets the lowest turbidity that can be measured accurately, so instruments with low stray light are needed for values near 0.02 NTU.
Yes, with a low-stray-light benchtop instrument, filtered zero water, clean vials and careful degassing. Reported values at this level carry high relative uncertainty, so instrument limits and calibration status should be stated on the report.
NTU stands for nephelometric turbidity unit, the scale used to report turbidity measured by light scattering at 90 degrees. It is defined against formazin standards, and instruments calibrated to different optical geometries may report different values for the same sample.
ISO 7027 uses near-infrared light around 860 nm, while EPA 180.1 uses a tungsten lamp with a broadband visible spectrum. The designs respond differently to coloured samples, so the method named in the regulation determines which instrument to use.
Formazin is the primary reference because it forms reproducibly and gives a defined scatter, so the NTU scale is traceable to it. It is toxic and unstable, so laboratories use stabilised formazin or cross-calibrated polymer standards for routine work.