Ratio Turbidity Meter with Dual Detectors

双检测器比值式浊度计

  • SKU TME-0003
  • Turbidity Meters
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Detectors90 degree plus forward scatter
Range0–10,000 NTU in ratio mode
Resolution0.01 NTU below 10 NTU
Accuracy±2 percent of reading plus 0.01 NTU
Light sourceLED 860 nm or tungsten
ModesNephelometric and ratio
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 7027-1, ISO 7027-2, EPA 180.1

What is the Ratio Turbidity Meter with Dual Detectors?

A ratio turbidity meter uses two or more detectors at different angles and divides their signals to compensate for colour and lamp drift. It measures coloured, absorbing and moderately turbid water more reliably than single-detector nephelometers.

What is the Ratio Turbidity Meter with Dual Detectors?

A ratio turbidity meter uses two or more detectors at different angles and divides their signals to compensate for colour and lamp drift. It measures coloured, absorbing and moderately turbid water more reliably than single-detector nephelometers.

Overview

In a single-detector nephelometer, coloured samples absorb both the incident and scattered light and cause negative bias, while lamp ageing changes the signal over time. A ratio instrument adds a forward-scatter or transmitted-light detector and divides the 90-degree signal by it, so common-mode changes cancel. The technique extends the linear range to higher turbidity and improves stability in samples such as treated wastewater, coloured surface water and beverages. Calibration uses multi-point standards and the ratio mode is validated against the specified method, since the ratio response differs from pure nephelometry. Instruments typically offer both nephelometric and ratio modes so that method-compliant readings and more stable routine readings can be obtained from the same instrument.

How does it work?

Nephelometric turbidity measurement shines a light beam into the sample and measures the light scattered at 90 degrees by suspended particles, since scattering increases with particle number, size and refractive index. ISO 7027 specifies the optical design, including wavelength and detector geometry, while EPA 180.1 specifies a tungsten lamp and a slightly different geometry, so instruments are usually labelled to one method. Ratio turbidimeters add a second or third detector at other angles and divide the signals, which compensates for colour and lamp ageing and extends the useful range. Backscatter instruments measure light scattered at angles greater than 90 degrees and suit high-turbidity samples beyond the range of nephelometry. Turbidity is formally a ratio of scattered to transmitted light and is reported in nephelometric turbidity units (NTU).

What are the key features?

  • 90-degree scatter plus forward or transmitted detector
  • Automatic ratio calculation to cancel common-mode drift
  • Dual nephelometric and ratio measurement modes
  • Extended linear range to higher turbidity
  • Multi-point calibration with sealed standards
  • Improved stability with coloured and absorbing samples

What are the technical specifications?

A typical ratio turbidity meter with dual detectors configuration offers detectors of 90 degree plus forward scatter, range of 0–10,000 NTU in ratio mode, resolution of 0.01 NTU below 10 NTU, accuracy of ±2 percent of reading plus 0.01 NTU, light source of LED 860 nm or tungsten and modes of Nephelometric and ratio. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Ratio Turbidity Meter with Dual Detectors is used in coloured surface water and effluent testing, treated wastewater compliance monitoring, beverage and syrup turbidity control and high-range process water measurement. Across the wider Turbidity Meters class, laboratories also deploy it for drinking water turbidity compliance testing, filter performance and backwash control and raw water and river quality monitoring.

Which standards and certifications apply?

Relevant standards and methods include ISO 7027-1, ISO 7027-2, EPA 180.1, Standard Methods 2130 B and ISO/IEC 17025. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Turbidity is sensitive to handling, so sample bottles should be clean and free of scratches, and measurements should be made promptly because particles settle and temperature changes. Dilution changes the particle population and is generally avoided. Formazin is the primary standard but is toxic and unstable, so stabilised formazin or polymer standards are used routinely and replaced before expiry. Low-level instruments need careful zeroing with ultrapure water and checks for stray light and bubbles, which cause positive bias. Online instruments require scheduled cleaning of the optical windows and verification against grab samples. Keep calibration records, and note the method and instrument model on every report, since results from different optical designs are not directly comparable.

How do I select the right Ratio Turbidity Meter with Dual Detectors?

Choose a ratio instrument when samples are coloured, strongly absorbing or moderately turbid, or when lamp drift is a concern over long runs. Confirm that the ratio mode is validated against your required method and that a pure nephelometric mode is available for compliance readings.

How does it compare with other Turbidity Meters variants?

Start from the method named in your regulation, because ISO 7027 and EPA 180.1 instruments are not interchangeable for compliance reporting. Portable meters suit field checks, river surveys and emergency sampling, while benchtop instruments give better repeatability and temperature control for laboratory compliance work. Ratio turbidimeters handle coloured or strongly absorbing samples better and reduce the effect of lamp drift. Choose a backscatter instrument when samples exceed the nephelometric range, as in sludge and raw wastewater. Online analyzers provide continuous data for filtration and coagulation control and are typically calibrated against the laboratory meter. Confirm the calibration standards, the range required and whether low-level resolution near 0.02 NTU is needed.

Full specifications

Full specifications
Detectors90 degree plus forward scatter
Range0–10,000 NTU in ratio mode
Resolution0.01 NTU below 10 NTU
Accuracy±2 percent of reading plus 0.01 NTU
Light sourceLED 860 nm or tungsten
ModesNephelometric and ratio
CalibrationUp to 6 points with standards
Colour compensationRatio based, automatic
Data storage1000+ readings with GLP data
InterfaceUSB, RS-232, LIMS export

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Coloured surface water and effluent testing
  • Treated wastewater compliance monitoring
  • Beverage and syrup turbidity control
  • High-range process water measurement

Key features

  • 90-degree scatter plus forward or transmitted detector
  • Automatic ratio calculation to cancel common-mode drift
  • Dual nephelometric and ratio measurement modes
  • Extended linear range to higher turbidity
  • Multi-point calibration with sealed standards
  • Improved stability with coloured and absorbing samples

Frequently asked questions about Ratio Turbidity Meter with Dual Detectors

Colour attenuates both the incident beam and the scattered light, so both detector signals fall together. Dividing one by the other cancels that common attenuation, leaving a value that better represents the suspended solids.