What are 5-Part Analyzers?

5-part hematology analyzers separate white cells into neutrophils, lymphocytes, monocytes, eosinophils and basophils using laser flow cytometry with fluorescence, and add flags for immature and abnormal cells. They serve hospital laboratories that need full differentials for oncology, pediatric, emergency and infectious disease patients.

5 models of 5-Part Analyzers

The 5 models below are current configurations; specifications are confirmed on quotation.

Five-Part Differential Hematology Analyzer

五分类血液分析仪

  • PAR-0001
  • 5-Part Analyzers
  • CE (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
  • NMPA class II registration (to be confirmed)
Throughput:
60–100 samples/h
Reportable parameters:
26 parameters including 5-part differential
Sample volume:
25 µL whole blood; 15 µL capillary mode
WBC linear range:
0.2–150 ×10⁹/L
PLT linear range:
10–1000 ×10⁹/L
Detection principle:
Impedance plus laser flow cytometry with fluorescence

A five-part differential hematology analyzer is a bench-top instrument that reports a complete blood count with neutrophils, lymphocytes, monocytes, eosinophils and basophils counted separately by laser flow cytometry. It is the standard choice for hospital laboratories that act on differential results.

Request a quote
View details

High-Throughput 5-Part Hematology Analyzer

高通量五分类血液分析仪

  • PAR-0002
  • 5-Part Analyzers
  • CE (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
  • NMPA class II registration (to be confirmed)
Throughput:
100–150 samples/h with 5-part differential
Autoloader capacity:
≥100 tubes with continuous loading
Reportable parameters:
28 parameters plus optional reticulocyte module
Sample volume:
25 µL whole blood
WBC linear range:
0.1–200 ×10⁹/L
Reagent capacity:
Onboard reagent for 500–800 tests

A high-throughput 5-part analyzer processes 100 to 150 samples per hour with continuous rack loading, which suits large hospital core laboratories and reference laboratories whose daily counts exceed several hundred samples. Sample review by a technologist, not instrument speed, becomes the limiting factor.

Request a quote
View details

5-Part Hematology Analyzer with Reticulocyte Count

带网织红细胞计数的五分类血液分析仪

  • PAR-0003
  • 5-Part Analyzers
  • CE (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
  • NMPA class II registration (to be confirmed)
Throughput:
60–80 samples/h with reticulocyte mode
Reticulocyte measuring range:
0.1–30 %
Reportable parameters:
Reticulocyte %, absolute count, IRF, NRBC
Sample volume:
25 µL whole blood
Detection principle:
Nucleic acid fluorescence plus impedance and scatter
Reticulocyte reagent stability:
60 days onboard at 20–25 °C protected from light

This analyzer adds a nucleic acid staining channel that quantifies reticulocytes and their maturity fractions alongside the five-part differential. It suits laboratories supporting hematology clinics, anemia workup and bone marrow transplant follow-up, where reticulocyte counts are requested daily.

Request a quote
View details

5-Part Hematology Analyzer with Autoloader and Barcode

带自动进样器和条码的五分类血液分析仪

  • PAR-0004
  • 5-Part Analyzers
  • CE (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
  • NMPA class II registration (to be confirmed)
Throughput:
80–100 samples/h with 5-part differential
Autoloader capacity:
10 racks of 10 tubes, continuous loading
Sample identification:
Barcode reader supporting code 128, code 39
Aspiration mode:
Closed-tube cap piercing, 25 µL
Reportable parameters:
26 parameters including 5-part differential
Mixer:
Automatic tube inversion before aspiration

This model pairs the five-part flow cytometry platform with a close-tube autoloader and full barcode identification, allowing batches to run unattended and results to match the worklist automatically. It suits hospital laboratories with peak batches and multiple wards sending tubes at the same time.

Request a quote
View details

Veterinary 5-Part Hematology Analyzer

兽用五分类血液分析仪

  • PAR-0005
  • 5-Part Analyzers
  • CE (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
  • Veterinary device registration (to be confirmed)
Throughput:
60–90 samples/h
Species profiles:
Dog, cat, horse, cattle, ferret, rodent presets
Reportable parameters:
26 parameters plus 5-part differential
Sample volume:
25 µL standard; 12 µL small-mammal mode
Anticoagulant:
EDTA-K2; heparin accepted in some modes
Platelet measurement:
Impedance and optical with species-specific thresholds

A veterinary 5-part analyzer applies species-specific calibration and reference intervals to a flow cytometry platform, giving five-part differentials for dogs, cats, horses and other animals. It is intended for veterinary referral hospitals and research facilities that need leukocyte detail for animal patients.

Request a quote
View details

Compare 5-Part Analyzers models

ModelThroughputReportable parametersSample volumeWBC linear rangeDetection principle
Five-Part Differential Hematology AnalyzerPAR-000160–100 samples/h26 parameters including 5-part differential25 µL whole blood; 15 µL capillary mode0.2–150 ×10⁹/LImpedance plus laser flow cytometry with fluorescence
High-Throughput 5-Part Hematology AnalyzerPAR-0002100–150 samples/h with 5-part differential28 parameters plus optional reticulocyte module25 µL whole blood0.1–200 ×10⁹/L—
5-Part Hematology Analyzer with Reticulocyte CountPAR-000360–80 samples/h with reticulocyte modeReticulocyte %, absolute count, IRF, NRBC25 µL whole blood—Nucleic acid fluorescence plus impedance and scatter
5-Part Hematology Analyzer with Autoloader and BarcodePAR-000480–100 samples/h with 5-part differential26 parameters including 5-part differential———
Veterinary 5-Part Hematology AnalyzerPAR-000560–90 samples/h26 parameters plus 5-part differential25 µL standard; 12 µL small-mammal mode——

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do 5-Part Analyzers work?

These analyzers combine impedance counting with a flow cytometry channel. A diluted and stained sample passes a sheath flow cell where hydrodynamic focusing aligns cells in single file. A laser beam strikes each cell, and three signals are recorded: forward scatter, which reflects cell size; side scatter, which reflects internal granularity and complexity; and fluorescence from a dye that stains nucleic acids and cell membranes. Clustering algorithms in the instrument software separate the signals into five leukocyte populations, and the same data support flags for band forms, blasts, atypical lymphocytes and nucleated red cells. Impedance channels measure red cells, platelets and a second white cell count for comparison. Hemoglobin is measured photometrically after lysis. Because the flow channel provides much more information than a size histogram, the analyzer can also report reticulocytes, immature platelet fraction and body fluid cell counts when the corresponding reagent and software options are installed.

Which 5-Part Analyzers variants are available?

  • Five-Part Differential Hematology Analyzer — A five-part differential hematology analyzer is a bench-top instrument that reports a complete blood count with neutrophils, lymphocytes, monocytes, eosinophils and basophils counted separately by laser flow cytometry.
  • High-Throughput 5-Part Hematology Analyzer — A high-throughput 5-part analyzer processes 100 to 150 samples per hour with continuous rack loading, which suits large hospital core laboratories and reference laboratories whose daily counts exceed several hundred samples.
  • 5-Part Hematology Analyzer with Reticulocyte Count — This analyzer adds a nucleic acid staining channel that quantifies reticulocytes and their maturity fractions alongside the five-part differential.
  • 5-Part Hematology Analyzer with Autoloader and Barcode — This model pairs the five-part flow cytometry platform with a close-tube autoloader and full barcode identification, allowing batches to run unattended and results to match the worklist automatically.
  • Veterinary 5-Part Hematology Analyzer — A veterinary 5-part analyzer applies species-specific calibration and reference intervals to a flow cytometry platform, giving five-part differentials for dogs, cats, horses and other animals.

How do I choose the right variant?

Specify a 5-part analyzer when clinicians act on the differential, for example to follow neutropenia during chemotherapy, to screen for leukemia, or to manage pediatric infections. Compare throughput, which ranges from about 60 to more than 120 samples per hour, and the first-result time for emergency work. Check which optional modes are included: reticulocyte count, nucleated red cell count, immature platelet fraction and body fluid analysis all require dedicated reagents and software licences. Confirm the minimum sample volume for pediatric samples and the linearity at low white cell counts. Ask about the flagging performance for blasts, the review rules the software applies, and whether a slide maker or digital morphology review is supported. Confirm LIS connectivity, reagent openness, calibration interval of the flow channel, and local service support.

Where are 5-Part Analyzers used?

5-Part Analyzers are specified in hospital routine and emergency blood counts, neutropenia and chemotherapy monitoring, leukemia and lymphoma screening, pediatric and neonatal blood counts and body fluid cell counts.

Which standards and certifications apply?

Work with 5-Part Analyzers is commonly governed by ISO 15189, CLSI H26-A2, CLSI H20-A2, CLSI EP05, CLSI H21, IEC 61010-1 and IEC 61010-2-101. Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

Install the analyzer on a stable bench with a dedicated grounded outlet, controlled room temperature of about 15 to 30 degrees Celsius and low dust. Verify performance at installation with precision, carryover, linearity and method comparison studies, including a specific check of the differential against manual microscopy on abnormal samples. Run three levels of control each day, join an external quality assessment scheme, and review flag rates regularly, because an excessive flag rate increases manual reviews and delays reporting. Clean the flow cell, probes and waste lines according to the maintenance plan, protect the laser and optics from vibration, and keep sheath fluid and cleaning reagents within their expiry dates. Handle all blood samples as potentially infectious.

Frequently asked questions about 5-Part Analyzers

A 5-part differential reports neutrophils, lymphocytes, monocytes, eosinophils and basophils separately rather than as grouped populations. This supports monitoring of neutropenia, allergic and parasitic conditions, and abnormal white cell patterns, and the underlying flow cytometry data also allow flags for immature cell populations.

Need help specifying 5-Part Analyzers?