What are 3-Part Analyzers?

3-part hematology analyzers are compact blood cell counters that group white cells into lymphocytes, monocytes with eosinophils, and granulocytes by impedance and size discrimination. They report a complete blood count with a three-part differential and suit clinics, small hospitals and outreach laboratories with low to moderate test volumes.

5 models of 3-Part Analyzers

The 5 models below are current configurations; specifications are confirmed on quotation.

Compact 3-Part Hematology Analyzer

紧凑型三分群血液分析仪

  • PAA-0001
  • 3-Part Analyzers
  • CE (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
  • NMPA class II registration (to be confirmed)
Throughput:
40–60 samples/h
Reportable parameters:
22 parameters including LYMPH%, MID%, GRAN%
Sample volume:
20 µL whole blood; 20 µL prediluted mode
WBC linear range:
0.3–99.9 ×10⁹/L
PLT linear range:
10–999 ×10⁹/L
Hemoglobin range:
0–250 g/L

A compact 3-part hematology analyzer is a bench-top blood cell counter that produces a complete blood count with a three-part white cell differential from about 20 microliters of whole blood. It is the right choice for clinics and small laboratories that need dependable routine counts within a small footprint and budget.

Request a quote
View details

Automated 3-Part Blood Cell Counter with Autoloader

带自动进样器的三分群血细胞分析仪

  • PAA-0002
  • 3-Part Analyzers
  • CE (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
  • NMPA class II registration (to be confirmed)
Throughput:
60–90 samples/h with 3-part differential
Autoloader capacity:
10 tubes per rack; up to 5 racks queued
Sample identification:
Barcode reader, code 128 and code 39
Aspiration mode:
Closed-tube cap piercing or open-tube
Reportable parameters:
22 parameters including three-part differential
Data storage:
50,000 patient records with QC history

An automated 3-part counter with an autoloader accepts racks of closed blood tubes and processes them without operator attendance, giving a three-part differential at moderate throughput. It suits clinics and small hospital laboratories that receive batches of fifty to one hundred samples in the morning peak.

Request a quote
View details

Semi-Automated 3-Part Blood Cell Counter

半自动三分群血细胞计数仪

  • PAA-0003
  • 3-Part Analyzers
  • CE (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
  • NMPA class II registration (to be confirmed)
Throughput:
20–40 samples/h
Reportable parameters:
18–22 parameters with three-part differential
Sample volume:
20 µL whole blood in 0.5 mL diluent
WBC linear range:
0.5–99.9 ×10⁹/L
Calibration:
Manual entry of calibrator values
Display:
LCD with alphanumeric keypad

A semi-automated 3-part blood cell counter requires the operator to present each diluted sample to the aspiration probe, then measures it automatically and prints a three-part count. It costs less than a fully automatic analyzer and is suited to very low workloads, mobile clinics and teaching laboratories.

Request a quote
View details

3-Part Hematology Analyzer with Integrated ESR Module

带集成血沉模块的三分群血液分析仪

  • PAA-0004
  • 3-Part Analyzers
  • CE (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
  • NMPA class II registration (to be confirmed)
Throughput:
50–60 blood counts/h; 20 ESR/h
ESR method:
Capillary photometry, 20–30 min accelerated
ESR measuring range:
0–120 mm/h
Sample type:
EDTA whole blood, one tube for both tests
Reportable parameters:
22 CBC parameters plus ESR
Temperature control:
37 °C ±0.5 °C for counting; 18–25 °C for ESR

This analyzer combines a 3-part blood count with an automated erythrocyte sedimentation rate module, so that one tube yields both results in a single run. It fits clinics that currently send ESR tests out or operate a separate manual Westergren stand.

Request a quote
View details

Veterinary 3-Part Hematology Analyzer

兽用三分群血液分析仪

  • PAA-0005
  • 3-Part Analyzers
  • CE (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
  • Veterinary device registration (to be confirmed)
Throughput:
40–60 samples/h
Species profiles:
Dog, cat, horse, cattle, small mammal presets
Sample volume:
20 µL standard; 10 µL small-mammal mode
Anticoagulant:
EDTA-K2 preferred; lithium heparin in some modes
Reportable parameters:
22 parameters plus three-part differential
Reference ranges:
Editable species-specific intervals

A veterinary 3-part analyzer is calibrated and software-configured for animal species such as dogs, cats and horses, giving a three-part differential with species-specific reference ranges. It suits veterinary clinics, animal hospitals and research facilities that process animal blood rather than human samples.

Request a quote
View details

Compare 3-Part Analyzers models

ModelThroughputReportable parametersSample volumeWBC linear rangeDisplay
Compact 3-Part Hematology AnalyzerPAA-000140–60 samples/h22 parameters including LYMPH%, MID%, GRAN%20 µL whole blood; 20 µL prediluted mode0.3–99.9 ×10⁹/L7-inch color LCD with touch operation
Automated 3-Part Blood Cell Counter with AutoloaderPAA-000260–90 samples/h with 3-part differential22 parameters including three-part differential———
Semi-Automated 3-Part Blood Cell CounterPAA-000320–40 samples/h18–22 parameters with three-part differential20 µL whole blood in 0.5 mL diluent0.5–99.9 ×10⁹/LLCD with alphanumeric keypad
3-Part Hematology Analyzer with Integrated ESR ModulePAA-000450–60 blood counts/h; 20 ESR/h22 CBC parameters plus ESR———
Veterinary 3-Part Hematology AnalyzerPAA-000540–60 samples/h22 parameters plus three-part differential20 µL standard; 10 µL small-mammal mode——

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do 3-Part Analyzers work?

A 3-part analyzer aspirates a small volume of anticoagulated whole blood, then splits it into separate channels for dilution and measurement. Red cells and platelets are counted in an isotonic diluent by the Coulter principle, in which each cell passing a small aperture displaces conductive electrolyte and creates a voltage pulse proportional to cell volume. White cells are counted in a second channel where a lysing reagent destroys red cell membranes while leaving white cells intact for sizing. The analyzer sorts white cells into three populations using two software thresholds on the size histogram: lymphocytes, a mixed population of monocytes, eosinophils and basophils, and granulocytes. Hemoglobin is released by lysis and measured photometrically at about 540 nm after conversion to a stable chromogen. Software computes indices such as MCV, MCH and MCHC, applies quality control rules, and stores or transmits the report.

Which 3-Part Analyzers variants are available?

  • Compact 3-Part Hematology Analyzer — A compact 3-part hematology analyzer is a bench-top blood cell counter that produces a complete blood count with a three-part white cell differential from about 20 microliters of whole blood.
  • Automated 3-Part Blood Cell Counter with Autoloader — An automated 3-part counter with an autoloader accepts racks of closed blood tubes and processes them without operator attendance, giving a three-part differential at moderate throughput.
  • Semi-Automated 3-Part Blood Cell Counter — A semi-automated 3-part blood cell counter requires the operator to present each diluted sample to the aspiration probe, then measures it automatically and prints a three-part count.
  • 3-Part Hematology Analyzer with Integrated ESR Module — This analyzer combines a 3-part blood count with an automated erythrocyte sedimentation rate module, so that one tube yields both results in a single run.
  • Veterinary 3-Part Hematology Analyzer — A veterinary 3-part analyzer is calibrated and software-configured for animal species such as dogs, cats and horses, giving a three-part differential with species-specific reference ranges.

How do I choose the right variant?

Choose a 3-part analyzer when the clinicians served mainly need total counts, hemoglobin and a basic differential, and when the daily workload is low enough that a 5-part flow cytometry channel would not be used. Compare variants by throughput in samples per hour, minimum aspiration volume for capillary sampling, whether the reagent system is open or proprietary, and the quality of the histogram display. Confirm autoloader capacity if more than fifty samples arrive in a batch, check barcode and LIS connectivity, and review the calibration and control materials offered. Ask about the expected life of the shear valve and pump tubing, because these parts dominate maintenance cost, and about local service response time for a clinic without an in-house engineer.

Where are 3-Part Analyzers used?

3-Part Analyzers are specified in routine complete blood counts in community clinics, anemia and infection screening, pre-operative and antenatal blood counts, monitoring during chronic disease follow-up and outreach and mobile health screening.

Which standards and certifications apply?

Work with 3-Part Analyzers is commonly governed by ISO 15189, CLSI H26-A2, CLSI H20-A2, CLSI EP05, IEC 61010-1 and IEC 61010-2-101. Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

Place the analyzer on a stable, level bench away from direct sunlight, strong vibration and large electrical motors, with a grounded outlet and a supply of clean, low-particulate water if the instrument needs it. Perform installation verification with the manufacturer or distributor, including background counts, precision, carryover and linearity checks with fresh or stabilized blood. Run two or three levels of quality control at the start of each working day and after reagent changes. Daily cleaning of the aspiration probe, weekly cleaning of the apertures and periodic replacement of pump tubing, seals and the peristaltic pump keep results stable. Treat all blood samples, waste and control material as potentially infectious and follow local biosafety rules for decontamination and disposal.

Frequently asked questions about 3-Part Analyzers

A three-part differential reports lymphocytes, a combined monocyte and eosinophil group usually labelled MID or mononuclear, and granulocytes, each as a percentage and absolute count. It gives total white cell count, red cell count, platelet count, hemoglobin, hematocrit and indices, which is sufficient for most routine screening.

Need help specifying 3-Part Analyzers?

Request a quote