Automated 3-Part Blood Cell Counter with Autoloader
带自动进样器的三分群血细胞分析仪
- SKU PAA-0002
- 3-Part Analyzers
- CE (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
- NMPA class II registration (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Throughput | 60–90 samples/h with 3-part differential |
|---|---|
| Autoloader capacity | 10 tubes per rack; up to 5 racks queued |
| Sample identification | Barcode reader, code 128 and code 39 |
| Aspiration mode | Closed-tube cap piercing or open-tube |
| Reportable parameters | 22 parameters including three-part differential |
| Data storage | 50,000 patient records with QC history |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 15189, CLSI H26-A2, CLSI H20-A2
What is the Automated 3-Part Blood Cell Counter with Autoloader?
An automated 3-part counter with an autoloader accepts racks of closed blood tubes and processes them without operator attendance, giving a three-part differential at moderate throughput. It suits clinics and small hospital laboratories that receive batches of fifty to one hundred samples in the morning peak.
What is the Automated 3-Part Blood Cell Counter with Autoloader?
An automated 3-part counter with an autoloader accepts racks of closed blood tubes and processes them without operator attendance, giving a three-part differential at moderate throughput. It suits clinics and small hospital laboratories that receive batches of fifty to one hundred samples in the morning peak.
Overview
This variant adds a rack-based autoloader and a cap-piercing or open-tube sampling mechanism to the standard 3-part platform. Tubes are loaded in racks of ten or more, identified by barcode, aspirated, and returned to the rack while the next sample is measured, so one operator can run a morning batch while performing other tasks. Mixing before aspiration is performed by rotating the tube or by an internal mixer, which reduces the risk of sedimentation error. Throughput is typically 60 to 90 samples per hour, and the instrument usually supports continuous loading so that STAT samples can be inserted without stopping the batch. The software handles automatic reruns, delta checks against the previous result and storage of several tens of thousands of records.
How does it work?
A 3-part analyzer aspirates a small volume of anticoagulated whole blood, then splits it into separate channels for dilution and measurement. Red cells and platelets are counted in an isotonic diluent by the Coulter principle, in which each cell passing a small aperture displaces conductive electrolyte and creates a voltage pulse proportional to cell volume. White cells are counted in a second channel where a lysing reagent destroys red cell membranes while leaving white cells intact for sizing. The analyzer sorts white cells into three populations using two software thresholds on the size histogram: lymphocytes, a mixed population of monocytes, eosinophils and basophils, and granulocytes. Hemoglobin is released by lysis and measured photometrically at about 540 nm after conversion to a stable chromogen. Software computes indices such as MCV, MCH and MCHC, applies quality control rules, and stores or transmits the report.
What are the key features?
- Rack-based autoloader holding ten or more closed tubes
- Continuous loading so STAT samples can interrupt a running batch
- Barcode identification with automatic worklist matching
- Tube mixing before aspiration to reduce sedimentation error
- Automatic rerun and delta check for flagged results
- Throughput of 60 to 90 samples per hour with three-part differential
What are the technical specifications?
A typical automated 3-part blood cell counter with autoloader configuration offers throughput of 60–90 samples/h with 3-part differential, autoloader capacity of 10 tubes per rack; up to 5 racks queued, sample identification of Barcode reader, code 128 and code 39, aspiration mode of Closed-tube cap piercing or open-tube, reportable parameters of 22 parameters including three-part differential and data storage of 50,000 patient records with QC history. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Automated 3-Part Blood Cell Counter with Autoloader is used in morning batch blood counts in clinics, small hospital laboratory routine hematology, occupational health and insurance screening and outpatient department blood counts. Across the wider 3-Part Analyzers class, laboratories also deploy it for routine complete blood counts in community clinics, anemia and infection screening and pre-operative and antenatal blood counts.
Which standards and certifications apply?
Relevant standards and methods include ISO 15189, CLSI H26-A2, CLSI H20-A2, CLSI EP05, IEC 61010-1 and IEC 61010-2-101. Certification candidates for this model are CE, ISO 13485 manufacturing and NMPA class II registration; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the analyzer on a stable, level bench away from direct sunlight, strong vibration and large electrical motors, with a grounded outlet and a supply of clean, low-particulate water if the instrument needs it. Perform installation verification with the manufacturer or distributor, including background counts, precision, carryover and linearity checks with fresh or stabilized blood. Run two or three levels of quality control at the start of each working day and after reagent changes. Daily cleaning of the aspiration probe, weekly cleaning of the apertures and periodic replacement of pump tubing, seals and the peristaltic pump keep results stable. Treat all blood samples, waste and control material as potentially infectious and follow local biosafety rules for decontamination and disposal.
How do I select the right Automated 3-Part Blood Cell Counter with Autoloader?
Specify this variant when more than about fifty tubes arrive together and staff cannot spend the peak hour at the analyzer. State the tube diameters and heights to be accepted, the barcode symbologies used locally, and whether cap piercing is required for biohazard safety. Confirm the rack queue size, the time needed to switch between rack types and the behaviour after a power interruption, and ask for a barcode read rate specification.
How does it compare with other 3-Part Analyzers variants?
Choose a 3-part analyzer when the clinicians served mainly need total counts, hemoglobin and a basic differential, and when the daily workload is low enough that a 5-part flow cytometry channel would not be used. Compare variants by throughput in samples per hour, minimum aspiration volume for capillary sampling, whether the reagent system is open or proprietary, and the quality of the histogram display. Confirm autoloader capacity if more than fifty samples arrive in a batch, check barcode and LIS connectivity, and review the calibration and control materials offered. Ask about the expected life of the shear valve and pump tubing, because these parts dominate maintenance cost, and about local service response time for a clinic without an in-house engineer.
Full specifications
| Throughput | 60–90 samples/h with 3-part differential |
|---|---|
| Autoloader capacity | 10 tubes per rack; up to 5 racks queued |
| Sample identification | Barcode reader, code 128 and code 39 |
| Aspiration mode | Closed-tube cap piercing or open-tube |
| Reportable parameters | 22 parameters including three-part differential |
| Data storage | 50,000 patient records with QC history |
| Interfaces | LAN with HL7 or ASTM; USB; RS-232 |
| Rerun and dilution | Automatic for out-of-range WBC and PLT |
| Power supply | AC 100–240 V, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Morning batch blood counts in clinics
- Small hospital laboratory routine hematology
- Occupational health and insurance screening
- Outpatient department blood counts
Key features
- Rack-based autoloader holding ten or more closed tubes
- Continuous loading so STAT samples can interrupt a running batch
- Barcode identification with automatic worklist matching
- Tube mixing before aspiration to reduce sedimentation error
- Automatic rerun and delta check for flagged results
- Throughput of 60 to 90 samples per hour with three-part differential
Frequently asked questions about Automated 3-Part Blood Cell Counter with Autoloader
Most autoloaders accept standard 13 and 16 millimeter diameter tubes with heights between 75 and 100 millimeters, and some offer interchangeable trays for pediatric tubes. Non-standard or short tubes may need a separate adapter. Specify the exact tubes used locally so that the supplier configures the correct tray.
The analyzer holds the result and displays a flag, such as a low or high count warning, and can move the tube to a review position or rerun it automatically. The operator then decides whether to repeat the count, prepare a blood film or request a new sample according to the laboratory review rules.
Autoloaders themselves do not increase carryover, but closed-tube sampling with a shared probe does require a wash step between samples, usually with a reagent that also prevents fibrin build-up. Carrying volume specifications are usually given as a percentage and should be verified during installation with high-low-high sample sequences.
A three-part differential reports lymphocytes, a combined monocyte and eosinophil group usually labelled MID or mononuclear, and granulocytes, each as a percentage and absolute count. It gives total white cell count, red cell count, platelet count, hemoglobin, hematocrit and indices, which is sufficient for most routine screening.
Many models offer a prediluted or capillary mode that accepts 10 to 20 microliters of capillary blood collected in a diluent tube, which is useful for children and for patients with poor venous access. Confirm the minimum volume and validate the mode against venous samples before routine use.
Typical tasks are daily probe cleaning and background check, weekly cleaning of the aperture and reagent lines with a cleaning solution, monthly inspection of peristaltic pump tubing, and replacement of tubing, seals and syringe parts at intervals given in the manual. Annual preventive maintenance by a service technician is recommended.
Related models