Veterinary 3-Part Hematology Analyzer

兽用三分群血液分析仪

  • SKU PAA-0005
  • 3-Part Analyzers
  • CE (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
  • Veterinary device registration (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Throughput40–60 samples/h
Species profilesDog, cat, horse, cattle, small mammal presets
Sample volume20 µL standard; 10 µL small-mammal mode
AnticoagulantEDTA-K2 preferred; lithium heparin in some modes
Reportable parameters22 parameters plus three-part differential
Reference rangesEditable species-specific intervals
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 15189, CLSI H26-A2, CLSI H20-A2

What is the Veterinary 3-Part Hematology Analyzer?

A veterinary 3-part analyzer is calibrated and software-configured for animal species such as dogs, cats and horses, giving a three-part differential with species-specific reference ranges. It suits veterinary clinics, animal hospitals and research facilities that process animal blood rather than human samples.

What is the Veterinary 3-Part Hematology Analyzer?

A veterinary 3-part analyzer is calibrated and software-configured for animal species such as dogs, cats and horses, giving a three-part differential with species-specific reference ranges. It suits veterinary clinics, animal hospitals and research facilities that process animal blood rather than human samples.

Overview

The hardware resembles a clinic 3-part analyzer, but the software holds separate calibration factors and reference intervals for each species, since red cell size, white cell counts and platelet distribution differ markedly between dogs, cats, horses and cattle. Sample types include EDTA whole blood, sometimes lithium heparin plasma or blood from small mammals, and the aspiration volume is often adjustable for small species such as rodents. Reporting includes species-specific flags for anemia, leukocytosis and thrombocytopenia, and some models offer feline reticulocyte or canine platelet indices. Validation for each species must be performed locally against manual counts, because manufacturer data may not cover the breeds and clinical conditions of a particular practice.

How does it work?

A 3-part analyzer aspirates a small volume of anticoagulated whole blood, then splits it into separate channels for dilution and measurement. Red cells and platelets are counted in an isotonic diluent by the Coulter principle, in which each cell passing a small aperture displaces conductive electrolyte and creates a voltage pulse proportional to cell volume. White cells are counted in a second channel where a lysing reagent destroys red cell membranes while leaving white cells intact for sizing. The analyzer sorts white cells into three populations using two software thresholds on the size histogram: lymphocytes, a mixed population of monocytes, eosinophils and basophils, and granulocytes. Hemoglobin is released by lysis and measured photometrically at about 540 nm after conversion to a stable chromogen. Software computes indices such as MCV, MCH and MCHC, applies quality control rules, and stores or transmits the report.

What are the key features?

  • Species-specific calibration factors and reference intervals
  • Adjustable sample volume for small mammals and rodents
  • Three-part white cell differential with species flags
  • EDTA whole blood and small-volume sample modes
  • Optional feline reticulocyte and canine platelet indices
  • Storage of patient records under animal identification numbers

What are the technical specifications?

A typical veterinary 3-part hematology analyzer configuration offers throughput of 40–60 samples/h, species profiles of Dog, cat, horse, cattle, small mammal presets, sample volume of 20 µL standard; 10 µL small-mammal mode, anticoagulant of EDTA-K2 preferred; lithium heparin in some modes, reportable parameters of 22 parameters plus three-part differential and reference ranges of Editable species-specific intervals. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Veterinary 3-Part Hematology Analyzer is used in veterinary clinic blood counts, animal hospital emergency assessment, laboratory animal health monitoring and breeding and zoo animal screening. Across the wider 3-Part Analyzers class, laboratories also deploy it for routine complete blood counts in community clinics, anemia and infection screening and pre-operative and antenatal blood counts.

Which standards and certifications apply?

Relevant standards and methods include ISO 15189, CLSI H26-A2, CLSI H20-A2, CLSI EP05, IEC 61010-1 and IEC 61010-2-101. Certification candidates for this model are CE, ISO 13485 manufacturing and Veterinary device registration; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Place the analyzer on a stable, level bench away from direct sunlight, strong vibration and large electrical motors, with a grounded outlet and a supply of clean, low-particulate water if the instrument needs it. Perform installation verification with the manufacturer or distributor, including background counts, precision, carryover and linearity checks with fresh or stabilized blood. Run two or three levels of quality control at the start of each working day and after reagent changes. Daily cleaning of the aspiration probe, weekly cleaning of the apertures and periodic replacement of pump tubing, seals and the peristaltic pump keep results stable. Treat all blood samples, waste and control material as potentially infectious and follow local biosafety rules for decontamination and disposal.

How do I select the right Veterinary 3-Part Hematology Analyzer?

Choose this variant only when animal samples dominate the workload, because species-specific calibration is the main reason to buy it. Specify the species you most often test, the smallest species for which you need reliable counts, and the anticoagulant you use. Request local validation data on at least twenty normal and twenty abnormal animals per species, since reference intervals from another region may not apply to your patients.

How does it compare with other 3-Part Analyzers variants?

Choose a 3-part analyzer when the clinicians served mainly need total counts, hemoglobin and a basic differential, and when the daily workload is low enough that a 5-part flow cytometry channel would not be used. Compare variants by throughput in samples per hour, minimum aspiration volume for capillary sampling, whether the reagent system is open or proprietary, and the quality of the histogram display. Confirm autoloader capacity if more than fifty samples arrive in a batch, check barcode and LIS connectivity, and review the calibration and control materials offered. Ask about the expected life of the shear valve and pump tubing, because these parts dominate maintenance cost, and about local service response time for a clinic without an in-house engineer.

Full specifications

Full specifications
Throughput40–60 samples/h
Species profilesDog, cat, horse, cattle, small mammal presets
Sample volume20 µL standard; 10 µL small-mammal mode
AnticoagulantEDTA-K2 preferred; lithium heparin in some modes
Reportable parameters22 parameters plus three-part differential
Reference rangesEditable species-specific intervals
Data storage10,000 patient records
InterfacesUSB, LAN, RS-232
Power supplyAC 100–240 V, 50/60 Hz

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Veterinary clinic blood counts
  • Animal hospital emergency assessment
  • Laboratory animal health monitoring
  • Breeding and zoo animal screening

Key features

  • Species-specific calibration factors and reference intervals
  • Adjustable sample volume for small mammals and rodents
  • Three-part white cell differential with species flags
  • EDTA whole blood and small-volume sample modes
  • Optional feline reticulocyte and canine platelet indices
  • Storage of patient records under animal identification numbers

Frequently asked questions about Veterinary 3-Part Hematology Analyzer

Cell size and count ranges differ between species: feline red cells are smaller than canine cells, and horses and cattle have larger platelets with different size distributions. Without species-specific thresholds and calibration, the three-part differential and the platelet count can be biased for a given animal.

Related models

All 3-Part Analyzers

Request a quotation for the Veterinary 3-Part Hematology Analyzer