What are UV-Vis?

UV-Vis spectroscopy instruments measure how a sample absorbs, transmits or reflects light between about 190 and 1100 nm, and sometimes out to 3300 nm. Researchers and analysts use them to identify chromophores, quantify concentration by Beer–Lambert law, follow reaction kinetics and characterize optical materials.

5 models of UV-Vis

The 5 models below are current configurations; specifications are confirmed on quotation.

Diode-Array UV-Vis Spectrophotometer

二极管阵列紫外可见分光光度计

  • UVV-0001
  • UV-Vis
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
Wavelength range:
190–1100 nm
Detector:
Photodiode array, 1024 elements
Spectral bandwidth:
1.5 nm
Wavelength accuracy:
±0.5 nm
Photometric range:
−0.3 to 3.0 A
Photometric accuracy:
±0.005 A at 1 A

A diode-array UV-Vis spectrophotometer images a full 190–1100 nm spectrum onto a detector array in well under one second. It is the appropriate choice for kinetic studies, unstable samples and chromatographic peak purity work where simultaneous multi-wavelength information is needed.

Request a quote
View details

Fiber-Optic CCD UV-Vis Spectrometer

光纤 CCD 紫外可见光谱仪

  • UVV-0002
  • UV-Vis
  • CE (to be confirmed)
  • RoHS (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Wavelength range:
200–850 nm or 350–1100 nm
Detector:
CCD, 2048 pixels
Optical resolution (FWHM):
0.3–2.0 nm
Integration time:
1 ms–10 s
Signal-to-noise ratio:
≥250:1 (single acquisition)
Stray light:
≤0.1%

A fiber-optic CCD UV-Vis spectrometer is a compact modular instrument that couples light from a source, cuvette holder or probe via optical fiber to a CCD array. It is the practical choice for in-situ, process and OEM measurements, with a spectrum available in milliseconds.

Request a quote
View details

UV-Vis-NIR Spectrophotometer with Integrating Sphere

带积分球的紫外可见近红外分光光度计

  • UVV-0003
  • UV-Vis
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
Wavelength range:
190–2500 nm
Spectral bandwidth (UV-Vis):
0.05–5 nm variable
Wavelength accuracy:
±0.1 nm (UV-Vis), ±0.4 nm (NIR)
Photometric range:
−6 to 6 A
Stray light:
≤0.00008% T at 220 nm (NaI)
Detectors:
PMT (UV-Vis), PbS or InGaAs (NIR)

A UV-Vis-NIR spectrophotometer with integrating sphere measures transmittance and diffuse or specular reflectance from 190 to 2500 nm or beyond. It is the standard research tool for glass, coatings, photovoltaic materials, powders and other solids that cannot be measured in a cuvette.

Request a quote
View details

UV-Vis Spectrophotometer with Peltier Multi-Cell Kinetics System

带帕尔贴多池动力学系统的紫外可见分光光度计

  • UVV-0004
  • UV-Vis
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Wavelength range:
190–1100 nm
Spectral bandwidth:
1 nm (fixed) or 0.5–4 nm variable
Cell positions:
6 or 12
Temperature range:
4–100 °C
Temperature accuracy:
±0.1 °C
Heating ramp rate:
0.1–10 °C/min

A UV-Vis spectrophotometer with a Peltier multi-cell holder measures up to six samples at precisely controlled temperatures with automatic cell positioning. It is chosen for enzyme kinetics, melting curve analysis and thermodynamic studies requiring time-resolved absorbance.

Request a quote
View details

Microplate UV-Vis Absorbance Spectrophotometer

微孔板紫外可见吸光光度计

  • UVV-0005
  • UV-Vis
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IVD Regulation 2017/746 where applicable (to be confirmed)
Wavelength range:
230–1000 nm
Wavelength selection:
Monochromator, 1 nm steps
Plate formats:
6- to 384-well
Photometric range:
0–4.0 A
Photometric accuracy:
±1% at 1.0 A (±0.010 A)
Read time (96-well):
≤60 s (single wavelength)

A microplate UV-Vis absorbance spectrophotometer reads 96- or 384-well plates at selectable wavelengths from about 230 to 1000 nm in seconds. It is used for high-throughput assays such as ELISA, protein quantification, cell viability and enzymatic screening.

Request a quote
View details

Compare UV-Vis models

ModelWavelength rangeDetectorSpectral bandwidthWavelength accuracyPhotometric range
Diode-Array UV-Vis SpectrophotometerUVV-0001190–1100 nmPhotodiode array, 1024 elements1.5 nm±0.5 nm−0.3 to 3.0 A
Fiber-Optic CCD UV-Vis SpectrometerUVV-0002200–850 nm or 350–1100 nmCCD, 2048 pixels———
UV-Vis-NIR Spectrophotometer with Integrating SphereUVV-0003190–2500 nm——±0.1 nm (UV-Vis), ±0.4 nm (NIR)−6 to 6 A
UV-Vis Spectrophotometer with Peltier Multi-Cell Kinetics SystemUVV-0004190–1100 nm—1 nm (fixed) or 0.5–4 nm variable—−4 to 4 A
Microplate UV-Vis Absorbance SpectrophotometerUVV-0005230–1000 nm———0–4.0 A

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do UV-Vis work?

UV-Vis instruments pass light of selected wavelength through or onto a sample and measure the ratio of transmitted or reflected intensity to a reference. Sources are typically a deuterium lamp for ultraviolet and a tungsten-halogen lamp for visible and near-infrared, often replaced by xenon flash lamps or LEDs in compact designs. Wavelength selection uses a scanning monochromator with a holographic grating, or a fixed grating that disperses light onto a diode-array or CCD detector so the whole spectrum is captured at once. Photomultiplier tubes, silicon photodiodes or InGaAs detectors convert the light to an electrical signal. Absorbance is calculated as −log10 of transmittance and relates to concentration by the Beer–Lambert law. Stray light, bandwidth and photometric linearity define performance at high absorbance, while integrating spheres and fiber probes adapt the same principle to solids, films and in-situ measurements.

Which UV-Vis variants are available?

  • Diode-Array UV-Vis Spectrophotometer — A diode-array UV-Vis spectrophotometer images a full 190–1100 nm spectrum onto a detector array in well under one second.
  • Fiber-Optic CCD UV-Vis Spectrometer — A fiber-optic CCD UV-Vis spectrometer is a compact modular instrument that couples light from a source, cuvette holder or probe via optical fiber to a CCD array.
  • UV-Vis-NIR Spectrophotometer with Integrating Sphere — A UV-Vis-NIR spectrophotometer with integrating sphere measures transmittance and diffuse or specular reflectance from 190 to 2500 nm or beyond.
  • UV-Vis Spectrophotometer with Peltier Multi-Cell Kinetics System — A UV-Vis spectrophotometer with a Peltier multi-cell holder measures up to six samples at precisely controlled temperatures with automatic cell positioning.
  • Microplate UV-Vis Absorbance Spectrophotometer — A microplate UV-Vis absorbance spectrophotometer reads 96- or 384-well plates at selectable wavelengths from about 230 to 1000 nm in seconds.

How do I choose the right variant?

Choose a UV-Vis spectroscopy instrument according to spectral speed, wavelength range, sample type and accessory needs. Diode-array and CCD instruments capture a full spectrum in under a second and suit kinetics or unstable samples, but stray light is higher than in scanning double-beam systems that remain the choice for high-absorbance work. Extending to 3300 nm with a PbS or InGaAs detector requires a UV-Vis-NIR system. Solid films, powders and coatings need an integrating sphere. Modular fiber-optic spectrometers fit process lines and OEM use, while microplate readers serve high-throughput assays. Compare bandwidth, stray light at 220 and 340 nm, photometric range, baseline flatness and software features. Specify temperature control if thermodynamic or enzyme kinetic measurements are planned.

Where are UV-Vis used?

UV-Vis are specified in reaction kinetics and enzyme assays, nanoparticle plasmon resonance characterization, thin-film and coating optical properties, protein and nucleic acid quantification, environmental and water chemistry and semiconductor band-gap determination.

Which standards and certifications apply?

Work with UV-Vis is commonly governed by ASTM E275, ASTM E925, ASTM E958, USP <857>, Ph. Eur. 2.2.25, ISO 8655-7 and GB/T 26798. Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

Allow lamps to warm up for 15–30 minutes and perform a baseline correction before every measurement session. Verify performance periodically using holmium oxide or didymium filters for wavelength accuracy, potassium dichromate solutions for photometric accuracy and sodium iodide or potassium chloride solutions for stray light. Use matched quartz cuvettes for the UV and keep optical surfaces clean and free of fingerprints. Replace the deuterium lamp after its rated life of around 2000 hours. Control ambient temperature and vibration, and keep dust and solvent vapors away from the optics. For regulated laboratories, schedule IQ/OQ/PQ and use software with audit trails and access control.

Frequently asked questions about UV-Vis

A diode-array instrument disperses all wavelengths onto a detector array and records the whole spectrum in under a second, which suits kinetics. A scanning system steps a monochromator through wavelengths one at a time, giving lower stray light and wider photometric range for demanding samples.

Need help specifying UV-Vis?