Skip to main content
Lab Manufacturers China

Tablet Dissolution Testers

片剂溶出度仪

TDT · Dissolution Testing Equipment · 5 models

By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <711>, USP <1092>, Ph. Eur. 2.9.3

Standards referenced

  • USP <711>
  • USP <1092>
  • Ph. Eur. 2.9.3
  • JP 6.10
  • ChP 0931
  • USP <724>
  • ASTM E2503
  • FDA Guidance on Dissolution Testing of Immediate Release Solid Oral Dosage Forms

What are Tablet Dissolution Testers?

Tablet dissolution testers measure the rate and extent at which the active ingredient of a tablet or capsule dissolves in a controlled medium at 37 °C. Pharmaceutical QC, formulation and regulatory laboratories use them for batch release, stability studies and bioequivalence support.

5 models of Tablet Dissolution Testers

The 5 models below are current configurations; specifications are confirmed on quotation.

Six-Vessel Basket/Paddle Dissolution Tester

六杯篮法桨法溶出度仪

  • TDT-0001
  • Tablet Dissolution Testers
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Apparatus types:
USP Apparatus 1 (basket), 2 (paddle)
Number of vessels:
6
Vessel volume:
1000 mL (100–4000 mL with adaptors)
Rotation speed:
25–250 rpm
Speed accuracy:
±1 rpm
Temperature range:
ambient +5 to 45 °C

A six-vessel dissolution tester runs USP Apparatus 1 (basket) and Apparatus 2 (paddle) on six 1 L vessels in a thermostatted water bath. It is the standard configuration for batch-release and stability dissolution testing of immediate-release tablets and capsules.

Request a quote
View details

Eight-Vessel Dissolution Tester

八杯溶出度仪

  • TDT-0002
  • Tablet Dissolution Testers
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Apparatus types:
USP Apparatus 1 (basket), 2 (paddle)
Number of vessels:
8
Vessel volume:
1000 mL (100–4000 mL with adaptors)
Rotation speed:
25–250 rpm
Speed accuracy:
±1 rpm
Temperature range:
ambient +5 to 45 °C

An eight-vessel dissolution tester extends the USP Apparatus 1/2 layout to eight stations, so a test batch plus reference standards or a blank can run in one cycle. It suits QC laboratories seeking higher throughput without moving to a larger automated system.

Request a quote
View details

Automated Dissolution Tester with Online UV Sampling

在线紫外取样自动溶出度仪

  • TDT-0003
  • Tablet Dissolution Testers
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Apparatus types:
USP Apparatus 1 and 2
Number of vessels:
6 or 8
Sampling method:
peristaltic pump or syringe, filtered
Detector:
flow-cell UV-Vis or fibre-optic probe
Wavelength range:
200–400 nm (extendable to 800 nm)
Sampling interval:
from 1 min per channel

An automated dissolution tester with online UV sampling combines a USP Apparatus 1/2 bath with a peristaltic or syringe sampler and a fibre-optic or flow-cell UV detector. It is the right choice for laboratories needing unattended, time-profile dissolution with direct concentration readout.

Request a quote
View details

Reciprocating Cylinder Dissolution Tester (USP Apparatus 3)

往复筒溶出度仪(USP 装置 3)

  • TDT-0004
  • Tablet Dissolution Testers
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Apparatus type:
USP Apparatus 3 (reciprocating cylinder)
Number of stations:
6 or 7 columns
Vessel volume:
100–300 mL
Dip rate:
5–40 dips/min
Stroke length:
10 cm nominal
Temperature range:
ambient +5 to 45 °C

A reciprocating cylinder dissolution tester operates USP Apparatus 3, dipping the dosage form in a glass tube with mesh ends up and down through a series of media. It is used for extended-release products that need pH-gradient or multi-stage release profiling.

Request a quote
View details

Transdermal Dissolution Tester (USP Apparatus 5/6)

透皮制剂溶出度仪(USP 装置 5/6)

  • TDT-0005
  • Tablet Dissolution Testers
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Apparatus types:
USP Apparatus 5 (paddle over disk), 6 (cylinder)
Number of vessels:
6
Vessel volume:
500–900 mL
Test temperature:
32 ± 0.5 °C
Rotation speed:
25–150 rpm
Paddle-to-disk distance:
25 ± 2 mm

A transdermal dissolution tester adapts a six-vessel bath to USP Apparatus 5 (paddle over disk) and Apparatus 6 (rotating cylinder) for patches and other transdermal delivery systems. It is used for release testing and batch comparison of transdermal products.

Request a quote
View details

Compare Tablet Dissolution Testers models

ModelApparatus typesNumber of vesselsVessel volumeRotation speedSpeed accuracy
Six-Vessel Basket/Paddle Dissolution TesterTDT-0001USP Apparatus 1 (basket), 2 (paddle)61000 mL (100–4000 mL with adaptors)25–250 rpm±1 rpm
Eight-Vessel Dissolution TesterTDT-0002USP Apparatus 1 (basket), 2 (paddle)81000 mL (100–4000 mL with adaptors)25–250 rpm±1 rpm
Automated Dissolution Tester with Online UV SamplingTDT-0003USP Apparatus 1 and 26 or 8—25–250 rpm—
Reciprocating Cylinder Dissolution Tester (USP Apparatus 3)TDT-0004——100–300 mL——
Transdermal Dissolution Tester (USP Apparatus 5/6)TDT-0005USP Apparatus 5 (paddle over disk), 6 (cylinder)6500–900 mL25–150 rpm—

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do Tablet Dissolution Testers work?

A dissolution tester places the dosage form in a vessel of temperature-controlled medium, usually 500–1000 mL of buffer or acid, and agitates it by a rotating basket (Apparatus 1), paddle (Apparatus 2), reciprocating cylinder (Apparatus 3) or flow of medium (Apparatus 4). Aliquots are withdrawn at specified times through filters and assayed by UV-Vis or HPLC. The key components are a thermostatted water bath or waterless heater, a drive head holding shaft speed within ±2 rpm, polished glass or plastic vessels of defined geometry, and calibrated shafts with minimal wobble. Hydrodynamics, shaft position, centering and vibration all influence results, so mechanical qualification is integral. Drug release follows Noyes–Whitney kinetics, where dissolution rate depends on surface area, solubility and boundary layer thickness, and sink conditions must be maintained so that the medium volume is at least three times the saturation volume.

Which Tablet Dissolution Testers variants are available?

  • Six-Vessel Basket/Paddle Dissolution Tester — A six-vessel dissolution tester runs USP Apparatus 1 (basket) and Apparatus 2 (paddle) on six 1 L vessels in a thermostatted water bath.
  • Eight-Vessel Dissolution Tester — An eight-vessel dissolution tester extends the USP Apparatus 1/2 layout to eight stations, so a test batch plus reference standards or a blank can run in one cycle.
  • Automated Dissolution Tester with Online UV Sampling — An automated dissolution tester with online UV sampling combines a USP Apparatus 1/2 bath with a peristaltic or syringe sampler and a fibre-optic or flow-cell UV detector.
  • Reciprocating Cylinder Dissolution Tester (USP Apparatus 3) — A reciprocating cylinder dissolution tester operates USP Apparatus 3, dipping the dosage form in a glass tube with mesh ends up and down through a series of media.
  • Transdermal Dissolution Tester (USP Apparatus 5/6) — A transdermal dissolution tester adapts a six-vessel bath to USP Apparatus 5 (paddle over disk) and Apparatus 6 (rotating cylinder) for patches and other transdermal delivery systems.

How do I choose the right variant?

Start with the apparatus type the monograph specifies: Apparatus 1 or 2 for most immediate-release products, Apparatus 3 for extended-release and pH-shift profiling, Apparatus 5 or 6 for patches. Then choose vessel count by throughput: six for routine QC, eight for batches with standards, and automated systems for unattended profiles. Consider temperature control (bath versus waterless), speed range and accuracy, and compatibility with an autosampler or UV interface. For regulated sites, require IQ/OQ documentation, mechanical calibration fixtures, and software with audit trail. Also check vessel volume range, because low-dose or poorly soluble products may need 100–250 mL mini-vessels or 2–4 L vessels.

Where are Tablet Dissolution Testers used?

Tablet Dissolution Testers are specified in pharmaceutical QC, generic drug bioequivalence support, formulation development, stability testing and transdermal product release testing.

Which standards and certifications apply?

Work with Tablet Dissolution Testers is commonly governed by USP <711>, USP <1092>, Ph. Eur. 2.9.3, JP 6.10, ChP 0931, USP <724>, ASTM E2503 and FDA Guidance on Dissolution Testing of Immediate Release Solid Oral Dosage Forms. Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

Place the tester on a vibration-free bench, level it, and keep it away from air currents and centrifuges. Perform mechanical calibration of shaft wobble, vessel centering, verticality, speed and temperature at installation and at regular intervals, and run performance verification with USP prednisone or salicylic acid calibrator tablets. Degas media to prevent bubbles, clean vessels after each run, inspect shafts and baskets for corrosion or damage, and replace filters per SOP. Documentation should cover IQ/OQ/PQ, calibration records, and data-integrity controls.

Frequently asked questions about Tablet Dissolution Testers

It measures the amount of active ingredient released from a tablet or capsule into a medium over time under controlled temperature and agitation. Results are compared with monograph limits to confirm batch consistency and predict in vivo release behavior.

Need help specifying Tablet Dissolution Testers?

Request a quote