Automated Dissolution Tester with Online UV Sampling
在线紫外取样自动溶出度仪
- SKU TDT-0003
- Tablet Dissolution Testers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Apparatus types | USP Apparatus 1 and 2 |
|---|---|
| Number of vessels | 6 or 8 |
| Sampling method | peristaltic pump or syringe, filtered |
| Detector | flow-cell UV-Vis or fibre-optic probe |
| Wavelength range | 200–400 nm (extendable to 800 nm) |
| Sampling interval | from 1 min per channel |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <711>, USP <1092>, Ph. Eur. 2.9.3
What is the Automated Dissolution Tester with Online UV Sampling?
An automated dissolution tester with online UV sampling combines a USP Apparatus 1/2 bath with a peristaltic or syringe sampler and a fibre-optic or flow-cell UV detector. It is the right choice for laboratories needing unattended, time-profile dissolution with direct concentration readout.
What is the Automated Dissolution Tester with Online UV Sampling?
An automated dissolution tester with online UV sampling combines a USP Apparatus 1/2 bath with a peristaltic or syringe sampler and a fibre-optic or flow-cell UV detector. It is the right choice for laboratories needing unattended, time-profile dissolution with direct concentration readout.
Overview
This variant pairs a six- or eight-vessel paddle/basket tester with automated sampling and in-line UV-Vis detection. Media is withdrawn through filtered probes by a peristaltic pump, passed through a flow cell in a diode-array or single-wavelength spectrophotometer, and returned to the vessel, or a fibre-optic dip probe measures directly in the vessel. The controlling software runs the method, applies calibration curves, reports percent released at each time point and generates profiles for f2 similarity comparison. Media replacement and sample correction for cumulative volume loss are calculated automatically. Filters, tubing and the flow path are flushed between samples to limit carry-over. Such systems reduce operator intervention and sampling timing errors, and with an audit trail and electronic signatures they support 21 CFR Part 11 and data-integrity expectations. They are typically used for profile studies where frequent sampling is impractical by hand.
How does it work?
A dissolution tester places the dosage form in a vessel of temperature-controlled medium, usually 500–1000 mL of buffer or acid, and agitates it by a rotating basket (Apparatus 1), paddle (Apparatus 2), reciprocating cylinder (Apparatus 3) or flow of medium (Apparatus 4). Aliquots are withdrawn at specified times through filters and assayed by UV-Vis or HPLC. The key components are a thermostatted water bath or waterless heater, a drive head holding shaft speed within ±2 rpm, polished glass or plastic vessels of defined geometry, and calibrated shafts with minimal wobble. Hydrodynamics, shaft position, centering and vibration all influence results, so mechanical qualification is integral. Drug release follows Noyes–Whitney kinetics, where dissolution rate depends on surface area, solubility and boundary layer thickness, and sink conditions must be maintained so that the medium volume is at least three times the saturation volume.
What are the key features?
- Filtered online sampling with automatic media replacement
- Flow-cell or fibre-optic UV detection with diode-array option
- Automatic calculation of percent released and cumulative correction
- Dissolution profile and f2 similarity reporting
- Flush cycles between samples to limit carry-over
- Audit trail and electronic signature support
What are the technical specifications?
A typical automated dissolution tester with online uv sampling configuration offers apparatus types of USP Apparatus 1 and 2, number of vessels of 6 or 8, sampling method of peristaltic pump or syringe, filtered, detector of flow-cell UV-Vis or fibre-optic probe, wavelength range of 200–400 nm (extendable to 800 nm) and sampling interval of from 1 min per channel. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Automated Dissolution Tester with Online UV Sampling is used in dissolution profile studies, generic drug f2 comparison, unattended stability dissolution and formulation development. Across the wider Tablet Dissolution Testers class, laboratories also deploy it for pharmaceutical QC, generic drug bioequivalence support and formulation development.
Which standards and certifications apply?
Relevant standards and methods include USP <711>, USP <1092>, Ph. Eur. 2.9.3, JP 6.10, ChP 0931, USP <724>, ASTM E2503 and FDA Guidance on Dissolution Testing of Immediate Release Solid Oral Dosage Forms. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the tester on a vibration-free bench, level it, and keep it away from air currents and centrifuges. Perform mechanical calibration of shaft wobble, vessel centering, verticality, speed and temperature at installation and at regular intervals, and run performance verification with USP prednisone or salicylic acid calibrator tablets. Degas media to prevent bubbles, clean vessels after each run, inspect shafts and baskets for corrosion or damage, and replace filters per SOP. Documentation should cover IQ/OQ/PQ, calibration records, and data-integrity controls.
How do I select the right Automated Dissolution Tester with Online UV Sampling?
Select the automated online UV tester when frequent time points, long unattended runs or data-integrity compliance are priorities. Specify wavelength range, path length of flow cells, number of vessels, filter type, required software validation documentation (IQ/OQ) and 21 CFR Part 11 features. Compounds without a UV chromophore require an HPLC-based sampling system instead.
How does it compare with other Tablet Dissolution Testers variants?
Start with the apparatus type the monograph specifies: Apparatus 1 or 2 for most immediate-release products, Apparatus 3 for extended-release and pH-shift profiling, Apparatus 5 or 6 for patches. Then choose vessel count by throughput: six for routine QC, eight for batches with standards, and automated systems for unattended profiles. Consider temperature control (bath versus waterless), speed range and accuracy, and compatibility with an autosampler or UV interface. For regulated sites, require IQ/OQ documentation, mechanical calibration fixtures, and software with audit trail. Also check vessel volume range, because low-dose or poorly soluble products may need 100–250 mL mini-vessels or 2–4 L vessels.
Full specifications
| Apparatus types | USP Apparatus 1 and 2 |
|---|---|
| Number of vessels | 6 or 8 |
| Sampling method | peristaltic pump or syringe, filtered |
| Detector | flow-cell UV-Vis or fibre-optic probe |
| Wavelength range | 200–400 nm (extendable to 800 nm) |
| Sampling interval | from 1 min per channel |
| Carry-over | ≤ 0.5% |
| Rotation speed | 25–250 rpm |
| Temperature control | 37.0 ± 0.5 °C |
| Data integrity | audit trail, e-signature, user levels |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Dissolution profile studies
- Generic drug f2 comparison
- Unattended stability dissolution
- Formulation development
Key features
- Filtered online sampling with automatic media replacement
- Flow-cell or fibre-optic UV detection with diode-array option
- Automatic calculation of percent released and cumulative correction
- Dissolution profile and f2 similarity reporting
- Flush cycles between samples to limit carry-over
- Audit trail and electronic signature support
Frequently asked questions about Automated Dissolution Tester with Online UV Sampling
Online UV is suitable when the active ingredient has a selective UV absorbance and excipients do not interfere. For multi-component products or interfering matrices, samples should be collected and analysed by HPLC as required by the monograph.
Carry-over is limited by flushing the flow path with fresh medium between samples and by using low-volume tubing. Acceptable carry-over is verified during method validation, often to 0.5% or less of the prior concentration.
Yes. When not returning the sample, the software applies cumulative volume correction and, if media replacement is enabled, calculates the dilution effect, so reported percent released reflects the actual dissolved amount at each time point.
It measures the amount of active ingredient released from a tablet or capsule into a medium over time under controlled temperature and agitation. Results are compared with monograph limits to confirm batch consistency and predict in vivo release behavior.
Follow the monograph. Apparatus 2 (paddle) suits most tablets, while Apparatus 1 (basket) is used for capsules and dosage forms that float. Both can run on a standard six-vessel tester by exchanging shaft attachments.
Dissolved air forms bubbles on the tablet, baskets and vessel walls during the test, which alters hydrodynamics and lowers apparent dissolution. Degassing by heat, filtration and vacuum, or helium sparging is required by USP <711> unless validated otherwise.