Eight-Vessel Dissolution Tester
八杯溶出度仪
- SKU TDT-0002
- Tablet Dissolution Testers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Apparatus types | USP Apparatus 1 (basket), 2 (paddle) |
|---|---|
| Number of vessels | 8 |
| Vessel volume | 1000 mL (100–4000 mL with adaptors) |
| Rotation speed | 25–250 rpm |
| Speed accuracy | ±1 rpm |
| Temperature range | ambient +5 to 45 °C |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <711>, USP <1092>, Ph. Eur. 2.9.3
What is the Eight-Vessel Dissolution Tester?
An eight-vessel dissolution tester extends the USP Apparatus 1/2 layout to eight stations, so a test batch plus reference standards or a blank can run in one cycle. It suits QC laboratories seeking higher throughput without moving to a larger automated system.
What is the Eight-Vessel Dissolution Tester?
An eight-vessel dissolution tester extends the USP Apparatus 1/2 layout to eight stations, so a test batch plus reference standards or a blank can run in one cycle. It suits QC laboratories seeking higher throughput without moving to a larger automated system.
Overview
The eight-vessel tester keeps the paddle and basket geometry of the six-vessel design but adds two stations, typically used for a reference standard, a placebo blank or additional units to reach Stage 2 (S2) without a second run. A single drive module turns all eight shafts in unison, so speed and temperature uniformity across a wider bath must be verified carefully. Bath circulation is enlarged and the heater rating is increased to maintain 37.0 ± 0.5 °C at all positions. The head is lifted by a motorized or hydraulic mechanism and is usually controlled from a touchscreen with stored methods. Sampling can be manual, or an eight-channel autosampler can be added. The footprint grows by roughly one third compared with a six-vessel tester, which should be considered in bench planning.
How does it work?
A dissolution tester places the dosage form in a vessel of temperature-controlled medium, usually 500–1000 mL of buffer or acid, and agitates it by a rotating basket (Apparatus 1), paddle (Apparatus 2), reciprocating cylinder (Apparatus 3) or flow of medium (Apparatus 4). Aliquots are withdrawn at specified times through filters and assayed by UV-Vis or HPLC. The key components are a thermostatted water bath or waterless heater, a drive head holding shaft speed within ±2 rpm, polished glass or plastic vessels of defined geometry, and calibrated shafts with minimal wobble. Hydrodynamics, shaft position, centering and vibration all influence results, so mechanical qualification is integral. Drug release follows Noyes–Whitney kinetics, where dissolution rate depends on surface area, solubility and boundary layer thickness, and sink conditions must be maintained so that the medium volume is at least three times the saturation volume.
What are the key features?
- Eight stations allowing test units plus standard or blank in one run
- Enlarged bath circulation for uniform temperature across all positions
- Touchscreen control with stored methods and user levels
- Compatible with eight-channel autosamplers
- Basket and paddle shafts interchangeable on all stations
- Audit-trail ready software option for data integrity
What are the technical specifications?
A typical eight-vessel dissolution tester configuration offers apparatus types of USP Apparatus 1 (basket), 2 (paddle), number of vessels of 8, vessel volume of 1000 mL (100–4000 mL with adaptors), rotation speed of 25–250 rpm, speed accuracy of ±1 rpm and temperature range of ambient +5 to 45 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Eight-Vessel Dissolution Tester is used in high-throughput batch QC, reference standard co-testing, stage 2 testing without rerun and formulation screening. Across the wider Tablet Dissolution Testers class, laboratories also deploy it for pharmaceutical QC, generic drug bioequivalence support and formulation development.
Which standards and certifications apply?
Relevant standards and methods include USP <711>, USP <1092>, Ph. Eur. 2.9.3, JP 6.10, ChP 0931, USP <724>, ASTM E2503 and FDA Guidance on Dissolution Testing of Immediate Release Solid Oral Dosage Forms. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the tester on a vibration-free bench, level it, and keep it away from air currents and centrifuges. Perform mechanical calibration of shaft wobble, vessel centering, verticality, speed and temperature at installation and at regular intervals, and run performance verification with USP prednisone or salicylic acid calibrator tablets. Degas media to prevent bubbles, clean vessels after each run, inspect shafts and baskets for corrosion or damage, and replace filters per SOP. Documentation should cover IQ/OQ/PQ, calibration records, and data-integrity controls.
How do I select the right Eight-Vessel Dissolution Tester?
Choose the eight-vessel tester when a run routinely needs more than six units, for example test units plus a standard and blank, or when S2 extension is frequent. Specify bath uniformity data at all eight positions, autosampler channel count, and bench space. If throughput exceeds two runs per shift, consider an automated system with integrated sampling.
How does it compare with other Tablet Dissolution Testers variants?
Start with the apparatus type the monograph specifies: Apparatus 1 or 2 for most immediate-release products, Apparatus 3 for extended-release and pH-shift profiling, Apparatus 5 or 6 for patches. Then choose vessel count by throughput: six for routine QC, eight for batches with standards, and automated systems for unattended profiles. Consider temperature control (bath versus waterless), speed range and accuracy, and compatibility with an autosampler or UV interface. For regulated sites, require IQ/OQ documentation, mechanical calibration fixtures, and software with audit trail. Also check vessel volume range, because low-dose or poorly soluble products may need 100–250 mL mini-vessels or 2–4 L vessels.
Full specifications
| Apparatus types | USP Apparatus 1 (basket), 2 (paddle) |
|---|---|
| Number of vessels | 8 |
| Vessel volume | 1000 mL (100–4000 mL with adaptors) |
| Rotation speed | 25–250 rpm |
| Speed accuracy | ±1 rpm |
| Temperature range | ambient +5 to 45 °C |
| Temperature uniformity | ±0.4 °C across vessels |
| Shaft wobble | ≤ 1.0 mm |
| Bath capacity | about 40 L |
| Power supply | 220 V AC, 50/60 Hz, about 1.8 kW |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- High-throughput batch QC
- Reference standard co-testing
- Stage 2 testing without rerun
- Formulation screening
Key features
- Eight stations allowing test units plus standard or blank in one run
- Enlarged bath circulation for uniform temperature across all positions
- Touchscreen control with stored methods and user levels
- Compatible with eight-channel autosamplers
- Basket and paddle shafts interchangeable on all stations
- Audit-trail ready software option for data integrity
Frequently asked questions about Eight-Vessel Dissolution Tester
It reduces analysis time when a run needs more than six units, because the standard or blank runs in parallel rather than as a second run. For a strict six-unit S1 test, it offers no speed advantage over a six-vessel unit.
On a single-drive eight-vessel tester all shafts rotate at the same speed. Different speeds in one run require a multi-drive or independent-station design, which is less common and typically used for method development.
It is more demanding because the bath is wider, so circulation design and heater power matter. Request temperature mapping at every position, and verify it during installation and periodic calibration.
It measures the amount of active ingredient released from a tablet or capsule into a medium over time under controlled temperature and agitation. Results are compared with monograph limits to confirm batch consistency and predict in vivo release behavior.
Follow the monograph. Apparatus 2 (paddle) suits most tablets, while Apparatus 1 (basket) is used for capsules and dosage forms that float. Both can run on a standard six-vessel tester by exchanging shaft attachments.
Dissolved air forms bubbles on the tablet, baskets and vessel walls during the test, which alters hydrodynamics and lowers apparent dissolution. Degassing by heat, filtration and vacuum, or helium sparging is required by USP <711> unless validated otherwise.
Related models