Skip to main content
Lab Manufacturers China

Cell Separation

细胞分离系统

CES · Cell Biology Equipment · 5 models

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 20387, USP <1046>, IEC 61010-1

Standards referenced

  • ISO 20387
  • USP <1046>
  • IEC 61010-1
  • IEC 61010-2-020
  • IEC 60825-1
  • ISO 15189

What are Cell Separation?

Cell separation systems isolate target cell populations from blood, bone marrow, tissue digests or cultured mixtures using magnetic labelling, fluorescence-activated sorting, microfluidic deflection or density-based methods. They supply purified cells for immunology, cell therapy and single-cell analysis.

5 models of Cell Separation

The 5 models below are current configurations; specifications are confirmed on quotation.

Magnetic-Activated Cell Separation System

磁性激活细胞分离系统

  • CES-0001
  • Cell Separation
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
Column capacity:
10⁷ to 10⁹ cells
Purity:
90–98% (marker dependent)
Viability:
above 90% (typical)
Processing time:
approx. 15–60 min
Sample volume:
0.5–50 mL
Magnetic field:
Permanent magnet, approx. 0.5–1 T at the column

A magnetic-activated cell separation system labels cells with antibody-conjugated magnetic particles and passes them through a column in a magnetic field, isolating labelled cells with 90–98% purity from 10⁷ to 10⁹ cells without a sorter.

Request a quote
View details

Fluorescence-Activated Cell Sorter

荧光激活细胞分选仪

  • CES-0002
  • Cell Separation
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
Lasers:
2–5 lines, typically 405, 488, 561 and 640 nm
Fluorescence detectors:
up to 20
Sort rate:
5,000–30,000 events per second
Purity:
98–99.9% (population dependent)
Recovery:
70–90% (typical)
Collection formats:
Tubes, plates and single-cell deposition

A fluorescence-activated cell sorter interrogates each cell in a fluid stream, applies a charge to droplets containing selected cells and deflects them into collection tubes, achieving 98–99.9% purity and depositing single cells into plates with index information.

Request a quote
View details

Microfluidic Cell Sorter

微流控细胞分选仪

  • CES-0003
  • Cell Separation
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
Throughput:
hundreds to a few thousand cells per second
Sample volume:
10 µL–5 mL
Channel size:
approx. 50–300 µm
Cell size range:
approx. 2–30 µm
Separation modes:
Acoustic, optical or pressure switching
Purity:
80–95% (mode dependent)

A microfluidic cell sorter deflects cells in narrow channels using acoustic waves, optical forces or fluid switching, isolating target populations from small samples with low shear stress and no aerosol generation, which suits delicate primary cells and limited clinical material.

Request a quote
View details

Buoyancy-Activated Cell Separation System

浮力激活细胞分离系统

  • CES-0004
  • Cell Separation
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
Separation time:
approx. 15–30 min after incubation
Sample volume:
1–50 mL
Cell number range:
10⁶–10⁹ cells
Separation mode:
Buoyancy (negative selection depletion)
Bubble density:
below 1.0 g/cm³
Purity:
85–95% (depletion dependent)

A buoyancy-activated cell separation system labels unwanted cells with antibody-conjugated glass microbubbles that float to the surface on standing, leaving the untouched target population in the lower layer without columns, magnets or centrifugation.

Request a quote
View details

Automated Density Gradient Cell Separation System

自动化密度梯度细胞分离系统

  • CES-0005
  • Cell Separation
  • CE (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Sample volume:
10–120 mL
Run time:
approx. 20–40 min
Mononuclear cell recovery:
60–90%
Viability:
above 95% (typical)
Density medium:
Polysaccharide and diatrizoate solution, 1.077 g/mL
Centrifugation:
approx. 400–800 x g for 20–30 min

An automated density gradient cell separation system layers blood or bone marrow over a density medium, centrifuges and collects the target interface automatically under closed conditions, reducing operator variation in mononuclear cell preparation.

Request a quote
View details

Compare Cell Separation models

ModelPurityViabilitySample volumeConsumablesDimensions (W x D x H)
Magnetic-Activated Cell Separation SystemCES-000190–98% (marker dependent)above 90% (typical)0.5–50 mLSingle-use columns and bead kitsapprox. 200 x 150 x 100 mm (magnet)
Fluorescence-Activated Cell SorterCES-000298–99.9% (population dependent)———approx. 1,000 x 800 x 900 mm
Microfluidic Cell SorterCES-000380–95% (mode dependent)above 90% (typical)10 µL–5 mL—approx. 300 x 400 x 300 mm
Buoyancy-Activated Cell Separation SystemCES-000485–95% (depletion dependent)above 90% (typical)1–50 mLAntibody-microbubble kits per sample typeapprox. 150 x 150 x 200 mm (rack)
Automated Density Gradient Cell Separation SystemCES-0005—above 95% (typical)10–120 mL—approx. 600 x 600 x 500 mm

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do Cell Separation work?

Separation exploits a physical or biochemical difference between the target and the rest of the sample. Immunomagnetic methods coat cells with antibody-conjugated magnetic particles and either retain labelled cells in a column placed in a magnetic field, or label everything except the target and let the desired cells flow through untouched. Fluorescence-activated sorting stains cells with fluorescent antibodies, interrogates each cell in a fluid stream and applies a charge to the droplet containing a selected cell, which is then deflected into a collection tube. Microfluidic sorters use narrow channels, acoustic waves or optical forces to deflect cells without droplets. Density-based separation layers the sample over a medium of defined density so that cells of different density band at different interfaces during centrifugation. Each method trades purity, yield, speed and gentleness differently, and downstream assays determine which balance is acceptable.

Which Cell Separation variants are available?

  • Magnetic-Activated Cell Separation System — A magnetic-activated cell separation system labels cells with antibody-conjugated magnetic particles and passes them through a column in a magnetic field, isolating labelled cells with 90–98% purity from 10⁷ to 10⁹ cells without a sorter.
  • Fluorescence-Activated Cell Sorter — A fluorescence-activated cell sorter interrogates each cell in a fluid stream, applies a charge to droplets containing selected cells and deflects them into collection tubes, achieving 98–99.9% purity and depositing single cells into plates with index information.
  • Microfluidic Cell Sorter — A microfluidic cell sorter deflects cells in narrow channels using acoustic waves, optical forces or fluid switching, isolating target populations from small samples with low shear stress and no aerosol generation, which suits delicate primary cells and limited clinical material.
  • Buoyancy-Activated Cell Separation System — A buoyancy-activated cell separation system labels unwanted cells with antibody-conjugated glass microbubbles that float to the surface on standing, leaving the untouched target population in the lower layer without columns, magnets or centrifugation.
  • Automated Density Gradient Cell Separation System — An automated density gradient cell separation system layers blood or bone marrow over a density medium, centrifuges and collects the target interface automatically under closed conditions, reducing operator variation in mononuclear cell preparation.

How do I choose the right variant?

Choose by the required purity, yield, cell number and downstream application. Magnetic separation is fast, gentle and scalable, works with 10⁷ to 10⁹ cells and needs no sorter, but purity is typically 90–98%, so it may not be sufficient for single-cell sequencing. Fluorescence-activated sorting reaches 98–99.9% purity, can deposit single cells into plates with index information and supports multi-parameter gating, at the cost of lower throughput, higher shear stress and specialised operation. Microfluidic and acoustic methods suit low-volume samples and cell types sensitive to shear. Density gradient separation remains the standard first step for blood and bone marrow, followed by magnetic or flow-based purification. Confirm compatibility of labels, buffers and consumables with downstream culture, functional assays and regulatory requirements.

Where are Cell Separation used?

Cell Separation are specified in T cell and immune subset isolation, stem cell and progenitor enrichment, cell therapy starting material preparation, single-cell sequencing sample preparation and rare cell isolation from blood samples.

Which standards and certifications apply?

Work with Cell Separation is commonly governed by ISO 20387, USP <1046>, IEC 61010-1, IEC 61010-2-020, IEC 60825-1 and ISO 15189. Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

Work in a biosafety cabinet with appropriate containment, and keep separation buffers cold unless the protocol states otherwise, since cells are more sensitive to handling than to the method itself. Use fresh antibodies and beads, avoid vigorous pipetting, and filter samples through a 30–40 µm mesh to prevent column or nozzle blockage. Include a dead-cell removal step, because dead cells bind non-specifically and reduce purity. After separation, verify purity and viability by flow cytometry and record recovery and purity values for each preparation. Aseptic technique and closed systems are required for cell therapy workflows, where separation is part of a validated process under ISO 20387 and USP <1046> expectations, including documented operator training and traceability of reagents and lots.

Frequently asked questions about Cell Separation

Positive selection labels the target cells so they are retained or collected. Negative selection labels everything except the target, so the desired cells remain untouched and unlabelled, which is preferred when the downstream assay is sensitive to bound antibody.

Need help specifying Cell Separation?

Request a quote