What are Cell Analyzers?

Cell analyzers interrogate living cells for surface markers, viability, cell cycle status and metabolic activity, using flow cytometry, spectral detection, imaging cytometry or extracellular flux measurement. They are used in immunology, cancer biology, cell therapy and bioprocess development.

5 models of Cell Analyzers

The 5 models below are current configurations; specifications are confirmed on quotation.

Benchtop Flow Cytometer Analyzer

台式流式细胞分析仪

  • CAN-0001
  • Cell Analyzers
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
Lasers:
488 nm standard, optional 405, 561 and 640 nm
Fluorescence detectors:
8–12 (configuration dependent)
Acquisition rate:
up to 50,000 events per second
Sample flow rate:
10–120 µL/min
Sample volume:
50–500 µL per acquisition
Fluorescence sensitivity:
approx. 100 MESF for FITC

A benchtop flow cytometer analyses cells in a single-file stream with two to four lasers and up to 12 detectors, quantifying surface markers, viability and cell cycle status in routine immunology and cell biology experiments.

Request a quote
View details

Spectral Flow Cytometer

光谱流式细胞仪

  • CAN-0002
  • Cell Analyzers
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
Spectral detectors:
20–60 narrow-band channels
Lasers:
3–5 lines, typically 355, 405, 488, 561 and 640 nm
Multiplex capacity:
16–40 colours
Acquisition rate:
up to 30,000 events per second
Unmixing method:
Linear unmixing with autofluorescence reference
Spectral resolution:
approx. 5–10 nm per channel

A spectral flow cytometer captures the full emission spectrum of every event across many detectors and unmixes overlapping fluorophores computationally, enabling panels of more than 12 colours and separating autofluorescence from true signal.

Request a quote
View details

Imaging Flow Cytometer

成像流式细胞仪

  • CAN-0003
  • Cell Analyzers
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
Imaging channels:
Brightfield plus 6–12 fluorescence channels
Magnification:
approx. 20x, 40x or 60x objectives
Throughput:
up to 5,000 cells per second
Camera:
High-speed time-delay integration CCD or CMOS
Lasers:
405, 488, 561 and 640 nm typical
Resolution:
approx. 0.5 µm per pixel at 60x

An imaging flow cytometer captures brightfield and multi-channel fluorescence images of every cell in flow, combining the statistical power of flow cytometry with microscopy-level morphology, signal localisation and cell-cell interaction data for detailed cell analysis.

Request a quote
View details

Metabolic Cell Analyzer

细胞代谢分析仪

  • CAN-0004
  • Cell Analyzers
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
Plate formats:
96-well and 24-well
Assay time:
approx. 60–120 min
Cells per well:
20,000–100,000 (cell type dependent)
Measured parameters:
Oxygen consumption rate and extracellular acidification rate
Sensor type:
Fluorescent optical oxygen and pH sensors
Injection ports:
4 per well

A metabolic cell analyzer measures oxygen consumption and extracellular acidification in intact cells within a multi-well plate, reporting mitochondrial respiration and glycolysis under basal and stressed conditions. It is used for immunometabolism, cancer metabolism and drug mechanism studies.

Request a quote
View details

Cell Cycle and Apoptosis Analyzer

细胞周期与凋亡分析仪

  • CAN-0005
  • Cell Analyzers
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
Laser:
488 nm, 20–50 mW
Detectors:
2–4 fluorescence channels plus scatter
Sample volume:
100–500 µL
Acquisition rate:
up to 10,000 events per second
Cell cycle output:
G0/G1, S and G2/M percentages with CV
Apoptosis assays:
Annexin V, caspase activity, membrane potential

A dedicated cell cycle and apoptosis analyzer measures DNA content and apoptotic markers with a fixed optical configuration, quantifying G0/G1, S and G2/M fractions and Annexin V or caspase signals in a simplified workflow.

Request a quote
View details

Compare Cell Analyzers models

ModelLasersAcquisition rateSample volumeCarry-overData output
Benchtop Flow Cytometer AnalyzerCAN-0001488 nm standard, optional 405, 561 and 640 nmup to 50,000 events per second50–500 µL per acquisitionbelow 1% with validated wash cycleFCS 3.1 files with gating statistics
Spectral Flow CytometerCAN-00023–5 lines, typically 355, 405, 488, 561 and 640 nmup to 30,000 events per second50–500 µL per acquisition——
Imaging Flow CytometerCAN-0003405, 488, 561 and 640 nm typical—50–500 µL per acquisition—Image files with FCS-like event data
Metabolic Cell AnalyzerCAN-0004—————
Cell Cycle and Apoptosis AnalyzerCAN-0005—up to 10,000 events per second100–500 µLbelow 1% with wash cycle—

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do Cell Analyzers work?

Flow-based cell analyzers suspend cells in a sheath fluid that hydrodynamically focuses them into a single file. Each cell passes one or more laser beams, and detectors record forward scatter, which relates to size, side scatter, which relates to granularity, and fluorescence from labelled antibodies or reporter proteins. Thousands of cells are measured per second, so rare populations can be quantified with statistical confidence. Spectral analyzers capture the full emission spectrum for each event and unmix overlapping dyes computationally, allowing larger panels. Imaging cytometers capture a brightfield and fluorescence image of each cell in flow, adding morphology and localisation information. Metabolic analyzers measure oxygen consumption and extracellular acidification in a plate by repeatedly sampling the medium above the cells, giving a readout of oxidative phosphorylation and glycolysis. Dedicated cell cycle analyzers measure DNA content and apoptosis markers with fixed panels.

Which Cell Analyzers variants are available?

  • Benchtop Flow Cytometer Analyzer — A benchtop flow cytometer analyses cells in a single-file stream with two to four lasers and up to 12 detectors, quantifying surface markers, viability and cell cycle status in routine immunology and cell biology experiments.
  • Spectral Flow Cytometer — A spectral flow cytometer captures the full emission spectrum of every event across many detectors and unmixes overlapping fluorophores computationally, enabling panels of more than 12 colours and separating autofluorescence from true signal.
  • Imaging Flow Cytometer — An imaging flow cytometer captures brightfield and multi-channel fluorescence images of every cell in flow, combining the statistical power of flow cytometry with microscopy-level morphology, signal localisation and cell-cell interaction data for detailed cell analysis.
  • Metabolic Cell Analyzer — A metabolic cell analyzer measures oxygen consumption and extracellular acidification in intact cells within a multi-well plate, reporting mitochondrial respiration and glycolysis under basal and stressed conditions.
  • Cell Cycle and Apoptosis Analyzer — A dedicated cell cycle and apoptosis analyzer measures DNA content and apoptotic markers with a fixed optical configuration, quantifying G0/G1, S and G2/M fractions and Annexin V or caspase signals in a simplified workflow.

How do I choose the right variant?

Define the panel before specifying hardware. Count how many fluorophores must be measured simultaneously, then check that the laser and detector configuration can resolve them, including compensation or spectral unmixing capability. Conventional benchtop systems suit routine 4–10 colour panels for immunophenotyping and cell cycle work. Spectral systems are appropriate when panels exceed about 12 colours or when autofluorescence varies between samples. Imaging cytometry answers questions involving cell shape, internalisation or cell-cell contact that scatter and fluorescence alone cannot resolve. Metabolic analysis addresses a different question entirely: how cells produce energy, and how they respond to inhibitors or genetic changes. All platforms need consistent sample preparation, validated compensation or unmixing controls, and documented acquisition settings so that results remain comparable between runs.

Where are Cell Analyzers used?

Cell Analyzers are specified in immunophenotyping of cell populations, cell cycle and apoptosis analysis, cell therapy product characterisation, metabolic phenotyping of immune and cancer cells and rare cell and stem cell detection.

Which standards and certifications apply?

Work with Cell Analyzers is commonly governed by IEC 60825-1, IEC 61010-1, ISO 15189, CLSI H42, USP <1046> and ISO 17025. Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

Standardise sample preparation, since cell number, staining volume, incubation time and wash steps all shift signal intensity. Include single-stain compensation controls and an unstained control in every experiment, and run reference beads for instrument setup and daily quality control. Keep sheath fluid and waste containers at the correct levels, and follow the manufacturer's cleaning procedure to limit carry-over below 1%. Lasers fall under IEC 60825-1, so protective covers and interlocks must remain functional and staff should be trained. Fixed cells for DNA content analysis need correct fixation and RNase treatment. For regulated work, document compensation, gating strategy, acquisition settings and software version, and retain raw FCS files so that analyses can be reproduced.

Frequently asked questions about Cell Analyzers

Conventional benchtop analysers typically resolve 4–12 fluorescence colours using two to four lasers, while spectral analysers support panels above 12 colours by capturing full emission spectra. Practical panel size is limited by dye overlap and by the number of available detectors.