Spectral Flow Cytometer
光谱流式细胞仪
- SKU CAN-0002
- Cell Analyzers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IEC 61010-1 safety (to be confirmed)
- IEC 60825-1 laser safety (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Spectral detectors | 20–60 narrow-band channels |
|---|---|
| Lasers | 3–5 lines, typically 355, 405, 488, 561 and 640 nm |
| Multiplex capacity | 16–40 colours |
| Acquisition rate | up to 30,000 events per second |
| Unmixing method | Linear unmixing with autofluorescence reference |
| Spectral resolution | approx. 5–10 nm per channel |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 60825-1, IEC 61010-1, ISO 15189
What is the Spectral Flow Cytometer?
A spectral flow cytometer captures the full emission spectrum of every event across many detectors and unmixes overlapping fluorophores computationally, enabling panels of more than 12 colours and separating autofluorescence from true signal.
What is the Spectral Flow Cytometer?
A spectral flow cytometer captures the full emission spectrum of every event across many detectors and unmixes overlapping fluorophores computationally, enabling panels of more than 12 colours and separating autofluorescence from true signal.
Overview
Instead of assigning one detector to one dye with a bandpass filter, the spectral instrument spreads each event's emission across a large array of narrow-band detectors and stores the full spectrum. Reference spectra recorded from single-stain controls define each fluorophore's signature, and the software solves the linear mixing problem to extract the contribution of every dye, including the sample's own autofluorescence, which is treated as an extra component and removed. This allows panels of 16 to 40 colours, improves resolution for dim markers, and reduces the re-optimisation effort when a panel changes. The trade-off is larger data files, longer acquisition setup and the need for well-characterised single-colour controls; unmixing quality depends directly on the accuracy of those reference spectra.
How does it work?
Flow-based cell analyzers suspend cells in a sheath fluid that hydrodynamically focuses them into a single file. Each cell passes one or more laser beams, and detectors record forward scatter, which relates to size, side scatter, which relates to granularity, and fluorescence from labelled antibodies or reporter proteins. Thousands of cells are measured per second, so rare populations can be quantified with statistical confidence. Spectral analyzers capture the full emission spectrum for each event and unmix overlapping dyes computationally, allowing larger panels. Imaging cytometers capture a brightfield and fluorescence image of each cell in flow, adding morphology and localisation information. Metabolic analyzers measure oxygen consumption and extracellular acidification in a plate by repeatedly sampling the medium above the cells, giving a readout of oxidative phosphorylation and glycolysis. Dedicated cell cycle analyzers measure DNA content and apoptosis markers with fixed panels.
What are the key features?
- Full-spectrum capture across 20 to 60 narrow-band detectors
- Linear unmixing with autofluorescence as a separate component
- Panels of 16 to 40 colours on a single sample
- Improved resolution of dim or overlapping markers
- Reference spectra from single-colour controls
- Automated unmixing and panel design software
What are the technical specifications?
A typical spectral flow cytometer configuration offers spectral detectors of 20–60 narrow-band channels, lasers of 3–5 lines, typically 355, 405, 488, 561 and 640 nm, multiplex capacity of 16–40 colours, acquisition rate of up to 30,000 events per second, unmixing method of Linear unmixing with autofluorescence reference and spectral resolution of approx. 5–10 nm per channel. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Spectral Flow Cytometer is used in high-parameter immunophenotyping panels, autofluorescence-heavy sample analysis, rare cell subset characterisation and cell therapy product deep phenotyping. Across the wider Cell Analyzers class, laboratories also deploy it for immunophenotyping of cell populations, cell cycle and apoptosis analysis and cell therapy product characterisation.
Which standards and certifications apply?
Relevant standards and methods include IEC 60825-1, IEC 61010-1, ISO 15189, CLSI H42, USP <1046> and ISO 17025. Certification candidates for this model are CE, ISO 9001 manufacturing, IEC 61010-1 safety and IEC 60825-1 laser safety; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Standardise sample preparation, since cell number, staining volume, incubation time and wash steps all shift signal intensity. Include single-stain compensation controls and an unstained control in every experiment, and run reference beads for instrument setup and daily quality control. Keep sheath fluid and waste containers at the correct levels, and follow the manufacturer's cleaning procedure to limit carry-over below 1%. Lasers fall under IEC 60825-1, so protective covers and interlocks must remain functional and staff should be trained. Fixed cells for DNA content analysis need correct fixation and RNase treatment. For regulated work, document compensation, gating strategy, acquisition settings and software version, and retain raw FCS files so that analyses can be reproduced.
How do I select the right Spectral Flow Cytometer?
Select a spectral analyser when panels require more than 12 colours, when samples autofluoresce strongly, or when panels change frequently. Specify laser lines, detector count, unmixing software, single-colour control requirements and data storage capacity, since spectral files are much larger.
How does it compare with other Cell Analyzers variants?
Define the panel before specifying hardware. Count how many fluorophores must be measured simultaneously, then check that the laser and detector configuration can resolve them, including compensation or spectral unmixing capability. Conventional benchtop systems suit routine 4–10 colour panels for immunophenotyping and cell cycle work. Spectral systems are appropriate when panels exceed about 12 colours or when autofluorescence varies between samples. Imaging cytometry answers questions involving cell shape, internalisation or cell-cell contact that scatter and fluorescence alone cannot resolve. Metabolic analysis addresses a different question entirely: how cells produce energy, and how they respond to inhibitors or genetic changes. All platforms need consistent sample preparation, validated compensation or unmixing controls, and documented acquisition settings so that results remain comparable between runs.
Full specifications
| Spectral detectors | 20–60 narrow-band channels |
|---|---|
| Lasers | 3–5 lines, typically 355, 405, 488, 561 and 640 nm |
| Multiplex capacity | 16–40 colours |
| Acquisition rate | up to 30,000 events per second |
| Unmixing method | Linear unmixing with autofluorescence reference |
| Spectral resolution | approx. 5–10 nm per channel |
| Sample volume | 50–500 µL per acquisition |
| Data file size | Larger than conventional FCS due to spectral channels |
| Software | Unmixing, panel design and compensation-free analysis |
| Dimensions (W x D x H) | approx. 700 x 800 x 700 mm |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- High-parameter immunophenotyping panels
- Autofluorescence-heavy sample analysis
- Rare cell subset characterisation
- Cell therapy product deep phenotyping
Key features
- Full-spectrum capture across 20 to 60 narrow-band detectors
- Linear unmixing with autofluorescence as a separate component
- Panels of 16 to 40 colours on a single sample
- Improved resolution of dim or overlapping markers
- Reference spectra from single-colour controls
- Automated unmixing and panel design software
Frequently asked questions about Spectral Flow Cytometer
Yes. A spectrum measured from unstained cells is treated as an additional component in the unmixing calculation, so broad autofluorescence is subtracted along with the dye signals. This improves resolution for dim markers in tissue or cultured cells.
A single-colour reference for every fluorophore in the panel, acquired with the same instrument settings as the samples, plus an unstained control for autofluorescence. Poor or mismatched references reduce resolution and can create false populations.
Yes. Because every event stores intensity values for tens of spectral channels, files are several times larger than conventional FCS files. Storage, backup and analysis server capacity should be planned before purchase.
Conventional benchtop analysers typically resolve 4–12 fluorescence colours using two to four lasers, while spectral analysers support panels above 12 colours by capturing full emission spectra. Practical panel size is limited by dye overlap and by the number of available detectors.
It measures oxygen consumption rate and extracellular acidification rate in a multi-well plate while injecting compounds. These readouts reflect mitochondrial respiration and glycolysis, allowing cells to be compared under different nutrients, inhibitors or genetic backgrounds.
Fluorophores emit across a range of wavelengths, so signal from one dye appears in detectors assigned to others. Single-stain controls allow the software to calculate and subtract that spillover, keeping populations in their correct quadrants and preventing false positive calls.