Live-Cell Imaging Incubation System
活细胞成像孵育系统
- SKU CEI-0003
- Cell Imaging
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IEC 61010-1 safety (to be confirmed)
- IEC 61010-2-010 safety (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Temperature control | ambient to 45 °C, within ±0.2 °C |
|---|---|
| CO2 control | 0–10%, within ±0.1% |
| Humidity | Maintained above 90% relative humidity |
| Oxygen control | Optional 1–21% |
| Vessel compatibility | Multi-well plates, dishes, flasks and chamber slides |
| Autofocus | Hardware or image-based, continuous during acquisition |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 60825-1, IEC 61010-1, IEC 61010-2-010
What is the Live-Cell Imaging Incubation System?
A live-cell imaging incubation system maintains temperature, carbon dioxide, humidity and often oxygen on the microscope stage while the software captures time-lapse sequences, so cell behaviour can be recorded continuously for hours or days.
What is the Live-Cell Imaging Incubation System?
A live-cell imaging incubation system maintains temperature, carbon dioxide, humidity and often oxygen on the microscope stage while the software captures time-lapse sequences, so cell behaviour can be recorded continuously for hours or days.
Overview
The system consists of a sealed chamber or stage-top incubator with heated glass, gas mixing, humidity control and a controller that holds set points within narrow tolerances, typically ±0.2 °C and ±0.1% CO2. A transparent heated lid limits condensation and evaporation, which is critical because medium evaporation changes osmolarity and causes focus drift. Camera-based or hardware autofocus corrects for thermal and mechanical drift over long runs, and low-intensity illumination with short exposures keeps phototoxicity within acceptable limits. Some systems also control oxygen for hypoxia work or allow perfusion to change media and add compounds during acquisition. Typical experiments run from a few hours to several days, capturing proliferation, migration, apoptosis and reporter dynamics.
How does it work?
All cell imaging systems collect light from a specimen and form an image on a detector. In widefield microscopy, the whole field is illuminated and the image is limited by out-of-focus light, so thin cells look sharp while thick specimens appear hazy. Confocal microscopy places a pinhole in front of the detector so that only light from the focal plane reaches it, and it scans point by point or line by line to build an optical section; this improves contrast and allows three-dimensional reconstruction. Fluorescence excitation comes from LEDs, lasers or arc lamps, and dichroic mirrors and emission filters separate the excitation from the emitted signal. Live-cell systems add an incubated stage or chamber to hold temperature, CO2 and humidity, and software captures time-lapse sequences. High-content systems combine automated plate handling, autofocus and image analysis to extract numerical features from thousands of images.
What are the key features?
- Temperature control within ±0.2 °C and CO2 within ±0.1%
- Heated transparent lid to limit evaporation and condensation
- Hardware or image-based autofocus for long acquisitions
- Optional oxygen control for hypoxia experiments
- Perfusion option for media exchange and compound addition
- Time-lapse scheduling with multi-position support
What are the technical specifications?
A typical live-cell imaging incubation system configuration offers temperature control of ambient to 45 °C, within ±0.2 °C, CO2 control of 0–10%, within ±0.1%, humidity of Maintained above 90% relative humidity, oxygen control of Optional 1–21%, vessel compatibility of Multi-well plates, dishes, flasks and chamber slides and autofocus of Hardware or image-based, continuous during acquisition. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Live-Cell Imaging Incubation System is used in cell proliferation and migration tracking, apoptosis and drug response kinetics, reporter gene and calcium signalling dynamics and stem cell and organoid growth monitoring. Across the wider Cell Imaging class, laboratories also deploy it for cell morphology and confluence assessment, immunofluorescence and protein localisation and live-cell dynamics and time-lapse studies.
Which standards and certifications apply?
Relevant standards and methods include IEC 60825-1, IEC 61010-1, IEC 61010-2-010, ISO 17025 and ISO 20387. Certification candidates for this model are CE, ISO 9001 manufacturing, IEC 61010-1 safety and IEC 61010-2-010 safety; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Optical cleanliness is essential, so objectives should be cleaned with lens tissue and the recommended solvent, and immersion oil removed after every session. Live-cell imaging requires careful control of temperature, CO2 and humidity, because evaporation changes osmolarity and focus drift spoils long time-lapse runs; hardware autofocus or a focus-maintenance routine is usually needed. Phototoxicity and photobleaching limit live experiments, so use the lowest illumination power and shortest exposure that gives an acceptable signal, and reduce the number of channels and time points. Laser systems fall under IEC 60825-1 and must remain interlocked. After installation, verify alignment with a calibration slide, then check stage repeatability and focus stability periodically, and keep records so that images from different sessions remain comparable.
How do I select the right Live-Cell Imaging Incubation System?
Select a live-cell incubation system when the experiment depends on continuous observation over hours or days. Specify temperature, CO2 and oxygen control ranges and tolerances, vessel compatibility, autofocus method, perfusion capability and the software scheduling features.
How does it compare with other Cell Imaging variants?
Match the system to the spatial and temporal resolution the experiment needs. Routine morphology, transfection checks and immunofluorescence on coverslips are well served by an inverted fluorescence microscope with LED illumination and a scientific camera. Confocal systems are needed when optical sections, thick specimens, three-dimensional reconstruction or low background matter, and spinning-disk confocals add speed for live imaging. Live-cell work requires an incubation chamber with CO2 and temperature control, plus low phototoxicity and a camera sensitive enough to limit exposure. High-content platforms are chosen when hundreds to thousands of wells must be imaged and quantified automatically. Check objective quality and numerical aperture, available fluorescence channels, detector sensitivity, stage automation, autofocus reliability, incubation performance and the analysis software, which often matters more than optics for quantitative results.
Full specifications
| Temperature control | ambient to 45 °C, within ±0.2 °C |
|---|---|
| CO2 control | 0–10%, within ±0.1% |
| Humidity | Maintained above 90% relative humidity |
| Oxygen control | Optional 1–21% |
| Vessel compatibility | Multi-well plates, dishes, flasks and chamber slides |
| Autofocus | Hardware or image-based, continuous during acquisition |
| Perfusion | Optional, with syringe or peristaltic pump |
| Run duration | hours to several days |
| Gas supply | Pre-mixed CO2 or CO2 and N2 |
| Dimensions (W x D x H) | approx. 300 x 400 x 150 mm (chamber) |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Cell proliferation and migration tracking
- Apoptosis and drug response kinetics
- Reporter gene and calcium signalling dynamics
- Stem cell and organoid growth monitoring
Key features
- Temperature control within ±0.2 °C and CO2 within ±0.1%
- Heated transparent lid to limit evaporation and condensation
- Hardware or image-based autofocus for long acquisitions
- Optional oxygen control for hypoxia experiments
- Perfusion option for media exchange and compound addition
- Time-lapse scheduling with multi-position support
Frequently asked questions about Live-Cell Imaging Incubation System
Within about ±0.2 °C at the sample, because small fluctuations cause focus drift and alter growth rates. A heated lid and pre-equilibrated gas supply reduce the fluctuations that occur when the chamber is opened.
Evaporation concentrates the medium, raising osmolarity and salt concentration, which stresses cells and changes focus as the meniscus moves. A humidified chamber with a heated lid limits water loss for multi-day experiments.
Use the minimum light dose that gives an adequate signal, reduce the number of channels, increase the interval between frames and choose fluorescent proteins excited at longer wavelengths. Including a control well without illumination helps separate light effects from biology.
Confocal is needed when out-of-focus light obscures the signal, for example in thick specimens, three-dimensional reconstructions, thick tissue and sections with high background. For thin cultured cells and bright markers, widefield imaging with a good camera is often sufficient.
An incubation chamber maintaining 37 °C, CO2 and humidity, hardware autofocus to correct focus drift, and low illumination intensity to keep phototoxicity acceptable. Objectives with a long working distance also help when using thick culture vessels.
Use the lowest light intensity and shortest exposure that still gives adequate signal, reduce the number of fluorescence channels and time points, choose fluorophores excited by longer wavelengths, and use widefield or spinning-disk systems where confocal illumination would be excessive.