Inverted Fluorescence Microscope for Cell Culture

细胞培养倒置荧光显微镜

  • SKU CEI-0001
  • Cell Imaging
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Objectives4x, 10x, 20x, 40x and 60x options
Fluorescence channels2–5 filter cubes (DAPI, FITC, TRITC, Cy5)
Light sourceLED, 365/470/550/620 nm options
CamerasCMOS or CCD, 4–20 MP
Contrast methodsBrightfield, phase contrast and relief contrast
StageFixed or motorised with multi-well plate insert
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 60825-1, IEC 61010-1, IEC 61010-2-010

What is the Inverted Fluorescence Microscope for Cell Culture?

An inverted fluorescence microscope views cells from below through the base of a culture vessel, with LED excitation and two to five filter sets for routine morphology and immunofluorescence. It is the standard bench instrument in cell culture laboratories.

What is the Inverted Fluorescence Microscope for Cell Culture?

An inverted fluorescence microscope views cells from below through the base of a culture vessel, with LED excitation and two to five filter sets for routine morphology and immunofluorescence. It is the standard bench instrument in cell culture laboratories.

Overview

The inverted design places objectives below a fixed stage, so cells in flasks, dishes and multi-well plates can be observed without transfer. LED illumination provides stable, long-life excitation with low heat output, and a turret of filter cubes selects excitation and emission bands for dyes such as DAPI, FITC, TRITC and Cy5. A scientific CMOS or CCD camera captures images, and phase contrast or relief contrast optics allow unstained cells to be visualised alongside fluorescence. Objectives from 4x to 40x cover overview and detail work, and 40x or 60x long working distance objectives are used for thick plastic-bottomed dishes. Motorised stages and autofocus on higher models support tiling and multi-well scanning, making the platform suitable for routine documentation and moderate-throughput analysis.

How does it work?

All cell imaging systems collect light from a specimen and form an image on a detector. In widefield microscopy, the whole field is illuminated and the image is limited by out-of-focus light, so thin cells look sharp while thick specimens appear hazy. Confocal microscopy places a pinhole in front of the detector so that only light from the focal plane reaches it, and it scans point by point or line by line to build an optical section; this improves contrast and allows three-dimensional reconstruction. Fluorescence excitation comes from LEDs, lasers or arc lamps, and dichroic mirrors and emission filters separate the excitation from the emitted signal. Live-cell systems add an incubated stage or chamber to hold temperature, CO2 and humidity, and software captures time-lapse sequences. High-content systems combine automated plate handling, autofocus and image analysis to extract numerical features from thousands of images.

What are the key features?

  • Inverted optics for direct observation of cells in culture vessels
  • LED illumination with two to five fluorescence filter cubes
  • Phase contrast or relief contrast for unstained cells
  • Scientific CMOS or CCD camera with adjustable exposure
  • Motorised stage and autofocus on higher models
  • Long working distance objectives for plastic-bottomed vessels

What are the technical specifications?

A typical inverted fluorescence microscope for cell culture configuration offers objectives of 4x, 10x, 20x, 40x and 60x options, fluorescence channels of 2–5 filter cubes (DAPI, FITC, TRITC, Cy5), light source of LED, 365/470/550/620 nm options, camera of sCMOS or CCD, 4–20 MP, contrast methods of Brightfield, phase contrast and relief contrast and stage of Fixed or motorised with multi-well plate insert. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Inverted Fluorescence Microscope for Cell Culture is used in routine culture morphology and confluence checks, immunofluorescence on coverslips and chamber slides, live-dead staining and viability assessment and transfection efficiency documentation. Across the wider Cell Imaging class, laboratories also deploy it for cell morphology and confluence assessment, immunofluorescence and protein localisation and live-cell dynamics and time-lapse studies.

Which standards and certifications apply?

Relevant standards and methods include IEC 60825-1, IEC 61010-1, IEC 61010-2-010, ISO 17025 and ISO 20387. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Optical cleanliness is essential, so objectives should be cleaned with lens tissue and the recommended solvent, and immersion oil removed after every session. Live-cell imaging requires careful control of temperature, CO2 and humidity, because evaporation changes osmolarity and focus drift spoils long time-lapse runs; hardware autofocus or a focus-maintenance routine is usually needed. Phototoxicity and photobleaching limit live experiments, so use the lowest illumination power and shortest exposure that gives an acceptable signal, and reduce the number of channels and time points. Laser systems fall under IEC 60825-1 and must remain interlocked. After installation, verify alignment with a calibration slide, then check stage repeatability and focus stability periodically, and keep records so that images from different sessions remain comparable.

How do I select the right Inverted Fluorescence Microscope for Cell Culture?

Select an inverted fluorescence microscope for routine observation, documentation and immunofluorescence where widefield imaging is adequate. Specify objective set and numerical aperture, fluorescence channels, light source, camera and whether a motorised stage, autofocus or stage incubator is required.

How does it compare with other Cell Imaging variants?

Match the system to the spatial and temporal resolution the experiment needs. Routine morphology, transfection checks and immunofluorescence on coverslips are well served by an inverted fluorescence microscope with LED illumination and a scientific camera. Confocal systems are needed when optical sections, thick specimens, three-dimensional reconstruction or low background matter, and spinning-disk confocals add speed for live imaging. Live-cell work requires an incubation chamber with CO2 and temperature control, plus low phototoxicity and a camera sensitive enough to limit exposure. High-content platforms are chosen when hundreds to thousands of wells must be imaged and quantified automatically. Check objective quality and numerical aperture, available fluorescence channels, detector sensitivity, stage automation, autofocus reliability, incubation performance and the analysis software, which often matters more than optics for quantitative results.

Full specifications

Full specifications
Objectives4x, 10x, 20x, 40x and 60x options
Fluorescence channels2–5 filter cubes (DAPI, FITC, TRITC, Cy5)
Light sourceLED, 365/470/550/620 nm options
CamerasCMOS or CCD, 4–20 MP
Contrast methodsBrightfield, phase contrast and relief contrast
StageFixed or motorised with multi-well plate insert
Working distanceup to approx. 10 mm with long working distance objectives
IncubationOptional stage incubator for temperature and CO2 control
Data outputTIFF images with acquisition metadata
Dimensions (W x D x H)approx. 300 x 500 x 500 mm

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Routine culture morphology and confluence checks
  • Immunofluorescence on coverslips and chamber slides
  • Live-dead staining and viability assessment
  • Transfection efficiency documentation

Key features

  • Inverted optics for direct observation of cells in culture vessels
  • LED illumination with two to five fluorescence filter cubes
  • Phase contrast or relief contrast for unstained cells
  • Scientific CMOS or CCD camera with adjustable exposure
  • Motorised stage and autofocus on higher models
  • Long working distance objectives for plastic-bottomed vessels

Frequently asked questions about Inverted Fluorescence Microscope for Cell Culture

Choose 4x or 10x for overview and confluence checks, 20x for routine detail, and 40x or 60x long working distance for fine detail in plastic-bottomed vessels. High numerical aperture objectives collect more light, which shortens exposures for fluorescence.

Related models

All Cell Imaging
Fluorescence Cell Imager — product photo

Fluorescence Cell Imager

荧光细胞成像仪

  • CE (to be confirmed)
  • +2
Request a quote
Spectral Flow Cytometer — product photo

Spectral Flow Cytometer

光谱流式细胞仪

  • CE (to be confirmed)
  • +3
Request a quote

Request a quotation for the Inverted Fluorescence Microscope for Cell Culture

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote